Development of an automated measurement system using a diffusion scrubber and high-performance liquid chromatography for the monitoring of formaldehyde and acetaldehyde in automotive exhaust gas

Abstract

An automated measurement system for monitoring formaldehyde (HCHO) and acetaldehyde (CH3CHO) in automotive exhaust gas by using a diffusion scrubber in combination with high-performance liquid chromatography (HPLC) was developed. HCHO and CH3CHO are effectively collected by the diffusion scrubber, which consists of a hydrophobic porous PTFE tube disposed concentrically within a Pyrex-glass tube and a scrubbing solution. 2,4-Dinitrophenylhydrazine is used as the scrubbing solution for trapping HCHO and CH3CHO, which are derivatized to formaldehyde 2,4-dinitrophenylhydrazone (DNPH-HCHO) and acetaldehyde 2,4-dinitrophenylhydrazone (DNPH-CH3CHO), respectively, with phosphoric acid as an acid catalyst. After the collection of the gas sample, the sample solution in the diffusion scrubber is injected into the HPLC system and DNPH-HCHO and DNPH-CH3CHO are separated and determined. All measurement operations are sequenced by a programmable controller and an automated continuous measurement can be performed at 10 min intervals. The collection efficiencies of HCHO and CH3CHO were higher than 97% at a gas flow rate of 0.2 l min–1. The detection limit (3ς of the blank value) was 0.001 ppm v/v for HCHO and CH3CHO for a 1.6 l gas sample volume. No interference of co-existing nitrogen dioxide (NO2) in the collection of HCHO and CH3CHO was observed. The average concentration of HCHO in the exhaust gas from methanol-fueled vehicles was 77.3 ppm v/v (n = 5) in the cold-phase mode when engines were first started. In the hot-phase mode, the average concentration of HCHO was 3.3 ppm v/v (n = 15). The concentrations of HCHO measured by this automated measurement system were in good agreement with those obtained using the impinger-HPLC method.

Article information

Article type
Paper

Analyst, 1998,123, 2343-2349

Development of an automated measurement system using a diffusion scrubber and high-performance liquid chromatography for the monitoring of formaldehyde and acetaldehyde in automotive exhaust gas

Y. Komazaki, Y. Narita and S. Tanaka, Analyst, 1998, 123, 2343 DOI: 10.1039/A805999C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements