Akshat
Joshi‡
a,
Saswat
Choudhury‡
a,
Arabinda
Majhi
b,
Sampath
Parasuram
c,
Vageesh Singh
Baghel
d,
Samrat
Chauhan
e,
Supriya
Khanra
e,
Debrupa
Lahiri
b and
Kaushik
Chatterjee
*ac
aDepartment of Bioengineering, Indian Institute of Science, C.V. Raman Avenue, Bangalore 560012, India. E-mail: kchatterje@iisc.ac.in; Tel: +91-80-22933408
bBiomaterials and Multiscale Mechanics Lab, Department of Metallurgical and Materials Engineering, Indian Institute of Technology Roorkee, Roorkee 247667, India
cDepartment of Materials Engineering, Indian Institute of Science, C.V. Raman Avenue, Bangalore 560012, India
dDepartment of Mechanical Engineering, Indian Institute of Science, C.V. Raman Avenue, Bangalore 560012, India
eChitkara College of Pharmacy, Chitkara University, Punjab 140401, India
First published on 11th July 2025
Conductive hydrogels are critical for advanced bioelectronics and the repair of electroactive tissues. However, developing conductive hydrogels into complex biomimetic shapes with good flexibility and bioactivity poses a major biofabrication challenge. This study utilizes dual-component hydrogel inks based on alginate incorporating conductive fCNT (acid-functionalized carbon nanotube) nanofillers, with the composite gel exhibiting an electrical conductivity of 6.6 ± 0.5 mS cm−1 at 2 mg ml−1 fCNT loading. Owing to their good combination of electrical conductivity and mechanical properties, the (three-dimensional) 3D-printed gels were successfully applied as strain sensors to sense subtle human motions, such as finger and elbow bending. Bilayered hydrogels prepared through four-dimensional (4D) printing exhibited programmable shape changes owing to differential swelling post-printing to yield nerve guidance conduits (NGCs) of intricate and tissue-adaptable designs, such as single and multichannel and bifurcated designs, based on accurate prediction by finite element analysis. The proliferation of neural cells was enhanced on the fCNT-gel compared to the neat gel. Sutureless deployment and enhanced peripheral nerve regeneration were established for the fCNT-gel in a rat sciatic nerve injury model. Overall, this work presents the fabrication of 4D-printed multifunctional conductive hydrogels, which can find diverse applications ranging from implantable nerve conduits to strain sensing.
Conductive gels find use as flexible strain sensors to sense subtle human motions19 and in the repair of electroactive tissues, such as neural,20 cardiac,21 and skeletal muscles.22 In recent times, neural tissue engineering has witnessed a paradigm shift towards gel-based nerve guidance conduits (NGCs).23 An ideal NGC should exhibit permeability, mechanical flexibility, a suitable degradation profile, tissue adaptability, and electrical conductivity for improved peripheral nerve repair.24 Soft hydrogels have been recognized as multifunctional NGCs, as they meet most of these requirements. However, even hydrogel-based NGCs suffer from several drawbacks, including a lack of suturability, limited designs to accommodate complex nerve defects, and the absence of inherent biochemical or electrical cues that can accelerate nerve regeneration.25 The electroactive properties of NGCs are crucial for the successful restoration of severed nerves, as they allow electricity transmission and activation of critical intracellular signaling pathways in electroactive neural tissues.26 Considering the previous advantages of gel-based NGCs, conductive gels with biomimetic shapes could offer a viable solution for treating peripheral nerve injury due to the synergistic effect of electrical cues and the ability of gels to mimic the native neural tissue.
To date, most conductive gel-based NGCs have been prepared by traditional methods, such as molding,27 dip-coating,28 and electrospinning.29 These hinder the possibility of complex designs of NGCs and customization suiting the individual needs of different patients. Advancements in additive manufacturing techniques, including four-dimensional (4D) printing, have led to the development of more dynamic, intricate, and tissue-adaptable medical devices.30 4D printing involves the use of stimuli-responsive materials, such as shape memory polymers, composites,31 multi-component hydrogels,32etc., often combined with anisotropic design principles33 to realize programmable shape changes post-printing. The shape changes are a consequence of the interaction of stimuli with the 3D-printed part.34 However, 4D fabrication has been rarely explored to prepare conductive hydrogel-based multifunctional NGCs.35 One study utilized a shape memory polymer incorporated with conductive MXene nanosheets to prepare temperature-activated self-rolled NGCs;36 however, the fabrication involves organic solvents and warrants multiple post-printing steps, such as freeze-drying and wrapping around a glass rod, and the stimulation relies solely on body temperature, which makes it unreliable and limits translation. We had earlier reported dual-component gels prepared by extrusion-based 3D printing that could self-roll in situ due to swelling gradients, forming hollow NGCs to clamp the distal and proximal ends of the severed nerve, thereby guiding the axons without the need for sutures.37 However, no studies have integrated electrical cues and complex tissue-adaptable designs to imitate the neural architecture with the sutureless neurorrhaphy technique. Such a synergistic technology will make the surgical procedure easier and patient-compliant and effectively enhance the functional recovery of neurons.
In the current study, multifunctional dual-component conductive hydrogels were utilized to develop bioinks with adequate printability through extrusion-based printing. The configured bioink (composition was carefully chosen to create significant swelling differences across the layers) was printed using optimized parameters. Given its good mechanical properties and electrical conductivity, the fCNT-gel was employed as a strain sensor to detect subtle human motions, such as elbow and finger bending. Coupled with predictive FEA simulations, several structures were printed that can yield different biomimetic designs of NGCs, such as single-channel, multichannel, and bifurcated hollow tubes post-printing (Fig. 1). Owing to the high electrical conductivity of the gels, the NGCs with fCNT revealed improved neural regeneration compared to the pristine gel NGCs. Overall, the technique proposed in the current research can open new avenues for diverse applications, including next-generation NGCs with improved peripheral nerve regeneration and strain sensors.
![]() | ||
Fig. 1 Schematic demonstration of 3D printing of conductive hydrogel inks at two different concentrations and application in strain sensing and different designs of self-folding NGCs. |
Next, the mechanical properties of the fCNT-gels were determined to validate their suitability as strain sensors. The fCNT-gels demonstrated an elastic modulus of ≈0.65 MPa and were stretchable, with a strain of ≈15% before failing (Fig. 2Ba). Cyclic stress–strain plots indicate the robust fatigue performance of the gels, with the final strain at the end of every cycle close to that of the preceding cycle for up to four consecutive cycles of loading and unloading without failure (Fig. 2Bb). Furthermore, the shape recovery ability of the composite gels was assessed at a stress of 0.02 MPa. There is no prominent hysteresis, and the strain at the end of every cycle was maintained at ≈5.5%. The % strain recovery was ≈100% for up to twenty cycles (Fig. 1B(c and d)). The improved cyclic mechanical properties can be attributed to the good dispersion and reinforcing effect of the fCNT nanofillers in the gel. There was no apparent deformation and stress reduction with increasing strain for up to four loading–unloading cycles. This is indicative of a robust interaction between the fCNTs and polymeric chains of the hydrogel, aided by well-dispersed fCNTs in the gel. The excellent electrical conductivity of the fCNT-gel combined with its good mechanical properties offers the opportunity to convert external stimuli, such as strain or pressure, into detectable electrical signals.40 To determine the efficacy of the conductive gels as strain sensors, ΔR/R0 was measured as a function of time and strain (Fig. 2B(e and f)). As seen from the calibration curve, ΔR/R0 increased monotonically with applied strain (till the strain at failure ≈15%), implying the applicability of the fCNT-gel as a strain sensor in the specified range. As a demonstration of monitoring human motions, the gel was placed on the finger and elbow, and the resulting ΔR/R0 was recorded in real time upon suitable movement of the finger and elbow. In the case of elbow flexing, a stable and repetitive pattern of resistance change was observed with the periodic movement of the elbow (Fig. 2Bg). Similarly, for finger bending, ΔR/R0 followed a stable trend with minimal fluctuations as the finger was bent and unbent periodically (Fig. 2Bh). The output ΔR/R0 signals remained stable and repeatable with minor fluctuations, which can be attributed to water evaporation. When the finger was bent with a stepwise increase in angles from 0 to 60°, 90°, and 150°, ΔR/R0 was 86, 94, and 99%, respectively (Fig. 2Bi). This indicates that the gel can sense different strain amplitudes.41 Additionally, ΔR/R0 remained constant when the finger was held stable at a specific angle. These results demonstrate the effectiveness of the fCNT-gel as a potential strain sensor to detect subtle human motions with sufficient stability and repeatability.
Next, the fCNT-gels of two distinct compositions (3/9 and 4/6) were 3D-printed into flat sheets of suitable dimensions, air-dried completely, and then exposed to barium chloride solution. The flat sheets could then self-morph into complete hollow tubes due to the significant differences in the extent of water uptake between the two gel layers (Fig. 3A(a–d) and S3†). A computational model was devised to predict the shape deformations of the 4D-printed structures with encoded infill patterns. A thermal expansion model was employed to simulate the deformations of the hydrogels after establishing a quantitative correlation between the swelling model. The details of the model used are provided in the ESI (section 1.4, ESI†). With the aim of obtaining a bifurcated NGC, an initial design of a T-shaped sheet was used, which later morphed into a perfusable, stable, and non-leaky T-junction (Fig. 3A(f–i) and Videos V1 and V2†). Bifurcated or T-junction NGC designs are posited to facilitate the separation of the growing axon bundles in a relatively biomimetic manner compared to simple hollow tubes.42 Similarly, multichannel NGCs were prepared by placing the self-rolled tubes of smaller diameters over a design-encoded flat sheet with a width similar to the lengths of the tubes, following which the sheet self-rolled into a hollow tube with the smaller tubes within its lumen (Fig. 3A(j) and Video V3†). Multichannel NGCs have been proven to effectively regenerate nerves by promoting the increased internal surface area for increased cell attachment,43 limiting the dispersion of axons,44 and offering higher mechanical stability and neuronal fascicular microstructure mimicking native nerves.45 To endow these NGCs with non-invasive imaging capabilities, barium chloride was used to crosslink the printed fCNT-gels. The barium ion crosslinked fCNT-gels display good contrast in X-ray imaging owing to the inherent radiopacity of barium ions46 (Fig. 3A(e)).
The in vitro cytocompatibility of neat and fCNT-gels was assessed using HT-22 (mouse hippocampal neuronal) cells. As seen from the Alamar Blue assay and live–dead staining, cellular viability was enhanced on fCNT-gels compared to neat gels owing to the presence of CNTs that are known to augment neuronal cell proliferation (Fig. 3B(a and b)). NF160 and nuclear staining revealed healthy morphology of cells in both neat and fCNT-gels, with more elongated cells observed on the fCNT-gels (Fig. 3Bc and Fig. S4†). This observation results from the favorable role of CNTs in promoting neurite extension.47 Neurite outgrowth, or extension, is crucial for neuronal migration, differentiation, and synaptic plasticity. Facilitating neurite outgrowth is essential for enhancing nerve regeneration and attaining functional recovery in instances of neurological impairment or disease. It is well reported that carbonaceous nanomaterials facilitate direct electronic current flow, which leads to the redistribution of charge along the cell membrane surface and direct electrical coupling between neuronal cells.48 Additionally, CNTs are also known to modulate downstream signaling by stimulating nerve growth factors and hence contribute to neurite outgrowth.49
The potential of neural regeneration of 4D-printed fCNT-gel conduits was estimated in vivo in a well-established 5 mm sciatic nerve defect in rats and monitored for up to 2 months and compared with neat polymeric (mentioned as gel) conduits (Fig. 4(A and B)). Both the gel and fCNT-gel conduits were able to intraoperatively self-wrap, thereby clamping the severed ends of the nerves upon exposure to barium chloride (Fig. S5†). The animals were randomly segregated into four groups: sham (no surgical damage), negative (no conduit at the injury site), neat (referred to as gel), and fCNT-gel. All experiments were carried out at the Chitkara College of Pharmacy, Chitkara University, India (approval number IAEC/CCP/23/02/PR-16) and followed CCSEA (Committee for Control and Supervision of Experiments on Animals) guidelines. A combination of functional and structural assessments was used to quantitatively assess the nerve regeneration. Functional assessment, such as the sciatic function index (SFI), was performed at specific intervals for 2 months, after which rats were sacrificed to assess the restoration of motor function in the wound-inflicted leg.
SFI is a measure of the activity in the sciatic nerve. SFI was calculated by comparing the geometric representation of the damaged hind paw of an injured rat with the representation of the contralateral paw. Herein, the paw prints of the operated legs and their corresponding contralateral paws of the animals from all the groups were taken on the 7th, 15th, 30th, 45th, and 60th days (compiled in Fig. 4C). In contrast to the negative control group, both the NGC-treated groups exhibited significant increments in SFI measurements on all the days post-surgery (Fig. 4D). The best SFI values for both the treated groups were observed on Day 60. However, between the two groups, the fCNT-gel group consistently exhibited a marked increase in SFI, demonstrating the superiority of conductive fCNT nanofillers in the gels compared to their neat counterpart.
Atrophy of the gastrocnemius muscle (GA) is a common complication following sciatic nerve damage. The regeneration of the sciatic nerve and reinnervation of the GA reduce muscle atrophy. GA weight analysis was used to evaluate muscle atrophy and neural regeneration. Post-sacrifice of the animals, the gastrocnemius muscles of both hind legs were removed and weighed. The left (L) (muscle weight of operated left leg)/right (R) (muscle weight of normal right leg) ratio was determined for all the groups (Fig. 4(G and H)). The lowest L/R ratio was observed for the negative group, whereas it was substantially improved in the case of conduit-treated groups. No significant difference in the L/R ratio was observed between the two treated groups (Fig. 4H). This observation was corroborated by the digital photographs of the gastrocnemius muscles (Fig. 4G). Muscle atrophy and regeneration were further assessed by hematoxylin and eosin (H&E) staining of the GA muscle (Fig. 4E), which revealed that the mass, integrity, and morphology of the muscle were considerably lost in the negative group. These parameters were markedly improved in animals treated with the 4D-printed NGCs (Fig. 4F), which were comparable to the sham group. Thus, both NGCs (gel and fCNT-gel) were successful in restoring the sciatic nerve, thereby reinnervating the gastrocnemius muscle and reducing muscular atrophy as a consequence of regeneration.
Histological investigation of the nerves in different groups revealed the success of neural tissue regeneration in the fCNT-gel groups. Regenerated nerve tissue was observed in the longitudinal slices of samples stained with H&E 2 months post-surgery (Fig. 5A). Here, the staining of the negative control group is excluded, as no nerve connection was established between the two resected ends. H&E staining of the cross sections (Fig. 5A[i–iii]) and longitudinal sections (Fig. 5A[iv–vi]) in the middle of the region covered by the gel-based NGC indicates the development of nerves and Schwann cells (SCs) into the implanted conduit, highlighting the restoration of injured nerves at the proximal end. Quantification of the H&E-stained positive area of the nerve from the gel and fCNT-gel groups (Fig. 5C) confirmed a higher amount of regenerating nerve fibers in the fCNT-gel group than in the former. Additionally, the integrity and morphology of the regenerated nerve were superior in the fCNT-gel group compared to the gel (Fig. 5(A and B)). This enhancement in the fCNT-gel group was possibly due to the conductive fCNT fillers in the lumen of the formed tube, which promote axon sprouting and nerve restoration. The electrical conductivity of the fCNT-gel provided an ideal environment for Schwann cells to grow on the fibers to utilize them as tracks on which the axon could be regenerated. The findings of the H&E staining demonstrated that the sham-operated group had intact nerve fibers. Nevertheless, further research is warranted to elucidate the underlying mechanisms.
Injury to peripheral nerves initiates a complex cascade of molecular events, eventually leading to nerve regeneration. These events include Wallerian degeneration, the axonal response for phagocytosis, chromatolysis, Schwann cell proliferation, axonal growth, and target reinnervation. NF160 (Neurofilament 160), a marker for neurofilaments, is typically seen in cells or tissues of neuronal origin. S100β (S100 calcium-binding protein B) is a characteristic marker for SCs. Thus, both the cross-sections and the longitudinal sections of the tissues were immunostained for NF-160 (green) and S100β (red), and the nuclei were counterstained with DAPI (Fig. 6A). NF-160 and S-100β proteins were expressed in all the groups, confirming the formation of myelin sheaths composed of SCs and the ingrowth of new axons in the 4D-printed gel and fCNT-gel. The highest NF-160 expression was observed in the sham group containing intact nerve fibers. Notably, the expression of NF-160 was higher in the fCNT-gel conduits than in the gel conduits (Fig. 6(A and B)). For S-100β, the sham group showed the least expression due to the absence of any regeneration, whereas the gel and fCNT-gel conduits exhibited increased S-100β expression due to neo-tissue formation (Fig. 6(A and C)). Notably, the fCNT-gel exhibited higher expression of S-100β when compared to the gel-NGC group. Thus, the conductive fCNT fillers augmented the efficacy of the 4D-printed gel conduit.
Histology of the vital organs, including the brain, spleen, kidneys, and liver, in gel and fCNT-gel implanted NGC groups revealed minimal inflammation in response to the implanted materials (Fig. S6†). These observations further underscore the superior biocompatibility of the 4D-printed NGCs.
There are few reports on 3D-printed multifunctional conductive hydrogels for applications in diverse areas.50 In this study, nanofillers of high electrical conductivity, namely, CNTs, were functionalized with carboxylic acid groups to improve their dispersion and interaction with the hydrogel matrix of alginate and methylcellulose. The composite gel (fCNT-gel) exhibited excellent electrical conductivity and mechanical stability and exhibited good sensing capabilities while detecting human movements, such as elbow and finger bending. Conductive hydrogels used for strain sensing are usually stretchable, with some of them exhibiting tensile strain as high as ≈140%. The conductivity varies from 0.018 mS cm−1 to 180 mS cm−1, depending on whether it is ionic or electronic conductivity, the kind of nanofiller, interaction with the polymer matrix, etc. However, they lack multifunctional attributes, such as printability, self-folding features, and biocompatibility. While the fCNT-gel prepared in this study had a tensile strain of ≈15%, it was sufficient to sense subtle human motions, such as finger bending. Moreover, it retained its printability and self-folding ability due to significant swelling differences between the layers. Most conductive gels for NGCs are limited to simple designs27 and require complex chemistries to synthesize.51 NGCs with self-wrapping abilities have been demonstrated in a few studies by using chitosan films with an encapsulated cryogel52 and a bi-layered gel of poly(N-isopropylacrylamide) (PNIPAm) and alginate.53 Currently, there are no reports of NGCs that can integrate electrical cues with self-folding ability, which can give rise to new avenues in designing next-generation NGCs with superior neural regeneration capabilities. In this study, complex designs of NGCs were prepared, including multichannel and bifurcated, which would be highly useful in regenerating large nerve defects in thicker fascicular nerves. While the current multi-channel NGCs have diameters (in the range of 5–6 mm) larger than that of the sciatic nerve of rodent models, further optimization can enhance the extent of bending in the printed structures to achieve smaller diameter multi-channel NGCs suitable for in vivo implantation. Additionally, the fCNT-gels exhibited superior neural regeneration potential compared to sham and gel groups in sciatic nerve defects of rats.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d5bm00166h |
‡ Equal contribution. |
This journal is © The Royal Society of Chemistry 2025 |