Rational design of ZnO@ZIF-8 nanoarrays for improved electrochemical detection of H2O2

Houshan Mei , Jiayue Xie , Zishuo Li , Chengming Lou , Guanglu Lei , Xianghong Liu and Jun Zhang *
College of Physics, Center for Marine Observation and Communications, Qingdao University, Qingdao 266071, China. E-mail: jun@qdu.edu.cn

Received 23rd December 2021 , Accepted 16th January 2022

First published on 17th January 2022


Abstract

Metal oxide nanostructures hold great promise in biosensors for non-enzymatic detection of H2O2. However, the interfacial or morphological changes of metal oxides during electrochemical reactions due to corrosion greatly reduce the service life and stability of the sensor. In this work, we propose the utilization of zeolite imidazole framework-8 (ZIF-8) as a functional layer to improve the H2O2 detection properties of ZnO nanorod arrays. Benefiting from the synergic interaction of the two materials, the core–shell ZnO@ZIF-8 nanoarrays demonstrate significantly enhanced electrochemical performance compared to pristine ZnO, delivering a wider linear range (20–11[thin space (1/6-em)]550 μM) at 0.6 V potential, higher sensitivity (4.47 μA mM−1 cm−2) and low detection limit (3 μM), as well as appealing long-term stability of up to 21 days. Post-TEM analysis reveals that the ZIF-8 shells can effectively protect the ZnO cores from corrosion when immersed in electrolyte to detect H2O2. The core–shell structure formed by coating metal–organic frameworks on metal oxides provides a new pathway for high performance chemical detection and other related fields.


1. Introduction

In recent years, detection of hydrogen peroxide (H2O2) has attracted significant attention because of its important role in food, agriculture, medicine and health, clinical control and environmental monitoring.1,2 Excess H2O2 produced by human metabolism can cause a series of central nervous system diseases and seriously harm people's health.3 At the same time, the formation of acid rain in nature is also connected to the formation of H2O2. Therefore, it is particularly important to develop a fast, efficient and stable H2O2 sensor. Among the various methods currently proposed for detecting H2O2, the electrochemical detection of H2O2 has become the simplest and most effective one due to its high sensitivity, low cost, and low power consumption.4

Due to their high surface-to-volume ratio, abundant molecular adsorption sites and high carrier mobility, one-dimensional (1D) metal oxide nanostructures such as nanowires and nanorods have demonstrated great potential in nanodevices, especially in the field of chemical sensors.5–8 Manipulating 1D units into three-dimensional (3D) nanoarray structures further enhances their application potential in chemical sensors.7,9,10 These 3D nanoarray structures can greatly improve the adsorption, reaction and diffusion of molecules due to the abundant space between 1D building blocks, thereby exhibiting better sensing performance.11

ZnO nanostructures have been widely used as sensing materials for H2O2 biosensors. Liu et al. reported a simple and rapid hydrothermal method to grow ZnO nanorods on stainless steel foil as H2O2 sensors with a low detection limit of 0.27 μM and a linear range of 0.1–100 μM.12 At the same time, Al-Hardan et al. reported a H2O2 sensor with ZnO nanorods grown on conductive glass as the sensing material. The prepared sensor has a linear range of 10–700 μM and a lower detection limit of 42 μM.13 In addition, Li et al. prepared Au–ZnO composite nanofibers by electrospinning as the electrode material of the H2O2 sensor, which has a good linear relationship and sensitivity in the range of 1–6000 μM, and a lower detection limit of 0.1 μM.14 Although the proposed H2O2 sensor based on the ZnO nanostructure has a wide linear range and a low detection limit, due to the inevitable agglomeration of ZnO used as a sensing material, the specific surface area and active center of the nanomaterial are reduced, thus reducing the service life and stability of the sensor. As a result, the current H2O2 sensor based on ZnO has difficulty maintaining a certain stability after 15 days. Therefore, there is an urgent need for a method to reduce or even avoid the corrosion and agglomeration of ZnO to improve the long-term stability and life of the sensor.

Due to their ordered structure, metal–organic frameworks (MOFs) as new multi-void crystalline materials have a large internal surface area.15–17 Recently, MOFs have been used to produce core–shell structures by encapsulating metal oxides.18 The obtained metal oxide@MOF materials exhibit novel physical and chemical properties in various sensor applications because of the unique molecule-screening functions of the MOF shells.19–21 As reported by Zhan et al.,22 a simple self-templating method was used to successfully synthesize ZnO@ZIF-8 nanorods for the detection of H2O2 and ascorbic acid. In this process, ZnO nanorods not only serve as templates, but also provide Zn2+ ions for the formation of ZIF-8. As expected, due to the different molecular sizes of H2O2 and ascorbic acid and the pore size limitation of ZIF-8, the detection of H2O2 and ascorbic acid showed completely different current signals. Meanwhile, it has been reported that Cu-MOF and Mn-MOF composites were able to protect carbon steel from corrosion at 3.5 wt% NaCl solution.23 It is noted that ZnO@zeolite imidazole framework-8 (ZnO@ZIF-8) core–shell materials have been frequently investigated as chemical gas sensors to selectively detect acetone24–26 and formaldehyde,27 while very rare attention has been paid to them as electrochemical sensors.22

In this work, we fabricate ZnO@ZIF-8 core–shell nanoarrays and explore their utilization in electrochemical sensors for H2O2 detection. Experiments show that the composite nanoarrays demonstrate high sensitivity and good linearity in a wide range of H2O2 concentrations. A very low detection limit of 3 μM has been obtained, which is 16-times lower than that of pristine ZnO. Meanwhile the ZnO@ZIF-8 sensor manifests excellent anti-interference ability against interfering molecules including dopamine (DA), ascorbic acid (AA), uric acid (UA), glucose (GO), lysine and NaCl in the electrolyte. Importantly, it is found that ZIF-8 layers also enable the sensor to have a long-term stability due to the protection of ZnO from corrosion as proved by post-TEM observation.

2. Experimental section

2.1 Chemicals

Zinc acetate, zinc nitrate hexahydrate, hexamethylenetetramine (HMT), N,N-dimethylformamide (DMF), and ethanol were purchased from Sinopharm Chemical Reagent Co. Polyethyleneimine (PEI) and 2-methylimidazole were purchased from Macleans. The phosphate buffer solution (PBS, 0.1 M) prepared by mixing sodium dihydrogen phosphate and sodium hydroxide solution and adjusted to the pH value of 7.0 is used as the supporting electrolyte for all test processes.

2.2 Fabrication of ZnO nanorod arrays

ZnO nanorod arrays were grown onto a glass substrate by a seed-assisted method following our previous work.11 Firstly, ZnO seeds were deposited on the substrate. Typically, 40 μL 0.06 M zinc acetate solution was dropped onto 1 × 1 cm2 ITO glass using a pipetting gun and dried at 80 °C. The obtained ITO was annealed at 350 °C for 30 min to prepare the seed layers. The ITO substrate was immersed in 80 mL of zinc nitrate hexahydrate (50 mM), HMT (60 mM) and PEI (3.6 mM) solution, and kept for 3 h at 90 °C, 8 h at 92.5 °C, 3 h at 95 °C, 4 h at 97.5 °C, 4 h at 105 °C, 2 h at 120 °C, and 2 h at 130 °C. Finally, the ZnO nanorod arrays were washed with deionized water and dried at 80 °C.

2.3 Preparation of ZnO@ZIF-8 nanorod arrays

The ZnO@ZIF-8 nanorod arrays were synthesized by a hydrothermal method. Typically, ZnO nanorod arrays were immersed in 40 mL of DMF/H2O (3[thin space (1/6-em)]:[thin space (1/6-em)]1 of v/v) mixed solution containing 2.5 mM 2-methylimidazole and kept in a Teflon-lined autoclave at 70 °C for 24 h. Finally, the ZnO@ZIF-8 nanorod arrays were washed with deionized water and dried at 70 °C.22

2.4 Characterization and electrochemical measurements

Under 200 kV pressure, ZnO and ZnO@ZIF-8 nanorods were observed using a transmission electron microscope (TEM) and a high resolution transmission electron microscope (HRTEM) on a JEM-2010. High-angle annular dark field scanning transmission electron microscopy (HAADF-STEM) and energy dispersive X-ray spectroscopy (EDX) elemental mapping were performed on an FEI Tecnai G20. Phase analysis was performed by powder X-ray diffraction (XRD). The surface composition of ZnO and ZnO@ZIF-8 was studied by X-ray photoelectron spectroscopy (XPS).

An electrochemical workstation (VSP, Bio-Logic) was used to record the cyclic voltammograms (CVs) of the sensor between 0 and 1.0 V (vs. Ag/AgCl) in 0.1 M PBS at 50 mV s−1. For chronoamperometry, under magnetic stirring, the current response of the sensor was recorded with the continuous dripping of hydrogen peroxide. The applied potential was 0.6 V (vs. Ag/AgCl). All electrochemical tests were performed at room temperature. For Mott–Schottky measurement, ZnO and ZnO@ZIF-8 nanoarrays were used as the working electrodes, the platinum sheet as the counter electrode, and Ag/AgCl as the reference electrode in 1 M Na2SO4 electrolyte.

3. Results and discussion

3.1 Morphological and structure characterization

The synthesis process of ZnO@ZIF-8 nanorod arrays is schematically shown in Fig. 1. The first step is to fabricate a zinc oxide seed layer on ITO. The second step is to synthesize ZnO nanorod arrays by a hydrothermal method. Then, ZnO nanorod arrays are converted into ZnO@ZIF-8 nanorod arrays by a hydrothermal method. Fig. 2(a and d) shows the TEM images of ZnO and ZnO@ZIF-8 nanorods. It can be observed that ZIF-8 is relatively completely coated on ZnO. Among them, the zinc oxide core of the ZnO@ZIF-8 nanorod is much thinner than the original ZnO nanorod. At the same time, Fig. 2 gives more details about the ZnO nanorod (b and c) and ZnO@ZIF-8 nanorod (e and f) through HRTEM. It can be observed from Fig. 2(c and f) that lattice fringes with a lattice spacing of 0.26 nm correspond to the (002) plane of zinc oxide.
image file: d1ce01704g-f1.tif
Fig. 1 Schematic illustration of the preparation of ZnO@ZIF-8 nanorod arrays.

image file: d1ce01704g-f2.tif
Fig. 2 TEM images of ZnO (a) and ZnO@ZIF-8 nanorods (d); HRTEM images of ZnO (b and c) and ZnO@ZIF-8 nanorods (e and f). The HAADF-STEM image with the corresponding mapping of ZnO (g–i) and ZnO@ZIF-8 nanorods (j–n).

The chemical elements of ZnO nanorods and ZnO@ZIF-8 nanorods were tested by HADDF-STEM and EDX. In Fig. 2(g–i), the elemental mapping images reveal the element distribution of Zn and O in ZnO nanorods. Fig. 2(j–n) also show the Zn, O, N and C elements in ZnO@ZIF-8 nanorods. The presence of N and C elements also reveals that ZIF-8 can be successfully transformed. It can be seen that ZIF-8 is well coated on ZnO nanorods, forming a core–shell structure of the ZnO@ZIF-8 nanorod. In addition, in Fig. 2(j), the ZnO nanorod as the core exhibits a brighter contrast than the ZnO@ZIF-8 nanorod due to its larger atomic mass.

Fig. 3 shows the XRD patterns of the ZnO nanorod and ZnO@ZIF-8 nanorod measured directly on ITO glass. It can be seen that the XRD patterns of the ZnO nanorod and ZnO@ZIF-8 nanorod are completely consistent with the wurtzite structure of zinc oxide (PDF#36-1451).28 In addition, compared to the ZnO nanorod, the peak at 10 to 20° in the ZnO@ZIF-8 nanorod corresponds to the lattice structure of the newly generated ZIF-8. And after being coated with ZIF-8, the additional new peaks appearing are consistent with the published simulation spectrum of the ZIF-8 structure data. The superposition of each group of diffraction peaks in ZnO@ZIF-8 indicates that ZnO and ZIF-8 coexist in the obtained nanocomposite.29


image file: d1ce01704g-f3.tif
Fig. 3 The XRD patterns of the ZnO nanorod and ZnO@ZIF-8 nanorod.

The Mott–Schottky curves of ZnO and ZnO@ZIF-8 nanorods are shown in Fig. 4(a). Both curves show a positive slope,30 indicating that both ZnO and ZnO@ZIF-8 nanorods exhibit n-type conductivity.30


image file: d1ce01704g-f4.tif
Fig. 4 (a) Mott–Schottky plots of the ZnO nanorod and ZnO@ZIF-8 nanorod. (b) XPS analysis of ZnO and ZnO@ZIF-8 nanorods, and high resolution spectra of Zn 2p (c), O 1s (d), N 1s (e) and C 1s (f).

XPS measurement was performed to determine the surface chemical states of ZnO and ZnO@ZIF-8 nanorods. As shown in Fig. 4(b), the survey scan of the ZnO@ZIF-8 nanorod shows Zn 2p, O 1s, N 1s, and C 1s, while only Zn 2p, O 1s and C 1s can be observed in the spectrum of ZnO. For the ZnO@ZIF-8 nanorod, the appearance of the N 1s peak and the enhancement of the C 1s peak indicate the successful synthesis of ZIF-8. For the two samples, the Zn 2p peaks of pure ZnO and ZnO@ZIF-8 are different. In ZnO, the peaks of the core-level spectrum of Zn 2p at 1044.24 eV and 1021.09 eV are attributed to Zn 2p1/2 and Zn 2p3/2.11 For ZnO@ZIF-8, the peak for Zn 2p3/2 is deconvoluted into two peaks, which belong to Zn–N (1021.46 eV) and Zn–O (1022.89 eV) respectively.31 In Fig. 4(c), the O 1s spectrum of ZnO can be fitted into three peaks at 532.24 eV, 530.89 eV and 529.69 eV, which are attributed to hydroxyl oxygen, adsorbed oxygen and lattice oxygen.32–34 The O 1s spectra of ZnO@ZIF-8 respectively at 534.06 eV, 531.51 eV and 529.96 eV are attributed to hydroxyl oxygen, adsorbed oxygen and lattice oxygen.8,29 Among them, due to the introduction of ZIF-8 with high specific surface area, ZnO@ZIF-8 (55.56%) has a much higher ratio of adsorbed oxygen than ZnO (48.83%). The N 1s fitting of ZnO@ZIF-8 has two peaks located at 400.86 eV and 398.76 eV, which belong to the N atom in the Zn–N bond and the N atom linked by imidazole (Fig. 4(e)).29 In Fig. 4(f), the two fitting peaks at 285.96 eV and 284.56 eV in the C 1s spectrum of ZnO@ZIF-8 correspond to the sp2 C bond in the heterocyclic ring N[double bond, length as m-dash]C–N and the sp2 hybridized C atom in the imidazole ring, respectively.29

3.2 Electrochemical detection of H2O2

Fig. 5(a) shows the electrochemical responses of different electrodes obtained by cyclic voltammetry (CV) in 0.1 M pH 7.0 PBS containing 1 mM H2O2. According to Li's report, since the impedance of the material increases after coating with ZIF-8, the current signal of ZnO is higher than that of ZnO@ZIF-8 at a lower potential.35 However, at a higher potential, the ZnO@ZIF-8 nanorod array has a higher current signal than the ZnO nanorod array. This is mainly due to the porous structure and larger specific surface area of the ZIF-8 coating, which increases the adsorbed oxygen content of the material, so more H2O2 molecules participate in the redox reaction, thereby improving the current signal.8Fig. 5(b) shows the cyclic voltammetry curves of ZnO@ZIF-8 nanorods in 0.1 M pH 7.0 PBS containing different concentrations of H2O2. The current response of ZnO@ZIF-8 nanorod arrays increases with the increase of H2O2 concentration. Due to the porosity of ZIF-8, H2O2 can pass through without hindering diffusion. Therefore, ZnO@ZIF-8 has relatively good performance as a sensing material for detecting H2O2.
image file: d1ce01704g-f5.tif
Fig. 5 (a) Cyclic voltammograms of the ZnO nanorod arrays and the ZnO@ZIF-8 nanorod arrays in the presence of 1 mM H2O2 in PBS (0.1 M, pH 7.0) at a scan rate of 50 mV s−1; (b) cyclic voltammograms of ZnO@ZIF-8 nanorod arrays in PBS including various concentrations of H2O2 at 50 mV s−1.

The fast and sensitive detection ability of ZnO and ZnO@ZIF-8 nanorod arrays for H2O2 was tested by the current response of continuously adding H2O2. As shown in Fig. 6, at a potential of 0.6 V, both ZnO and ZnO@ZIF-8 nanorod arrays show a clear current response to the addition of H2O2, and can reach 95% of the steady-state current value within 5 s. However, as shown in Fig. 6(b, d and f), after the long-term current response to the addition of H2O2, it is found that the current response and sensitivity of ZnO nanorod arrays continue to decrease, while the current response and sensitivity of ZnO@ZIF-8 nanorod arrays almost remain in a stable state. The sensitivity of ZnO nanorod arrays was 0.00599 μA μM−1 cm−2 on the first day, but after twenty one days, the sensitivity of the test dropped to 0.0008 μA μM−1 cm−2. The sensitivity of ZnO@ZIF-8 nanorod arrays remains above 0.004 μA μM−1 cm−2. A sensitivity of 0.00477 μA μM−1 cm−2 can be reached in the first test. The reason for the analysis may be due to ZnO nanorod arrays corroding after long-term testing, and ZnO@ZIF-8 nanorod arrays can maintain the stability of detecting H2O2 due to the protection of ZIF-8. By fitting the response current value in Fig. 6(e), the linear regression equations of ZnO nanorod arrays and ZnO@ZIF-8 nanorod arrays are I (μA) = 2.70 + 0.0008C (μM) and I (μA) = 5.64 + 0.0048C (μM), and the correlation coefficients (R2) are 0.996 and 0.992, respectively. In addition, the result of the lower limit of detection (LOD) is based on the ratio of the standard deviation (SD) of the current response to the slope of the calibration curve at a signal-to-noise ratio (SNR) of 3:36,37


image file: d1ce01704g-f6.tif
Fig. 6 The current response of ZnO and ZnO@ZIF-8 nanorod arrays to successive addition of H2O2 in PBS (0.1 M, pH 7.0) at an applied potential of 0.6 V on the first day (a and b), the seventh day (c and d) and the twenty-first day (e and f).


image file: d1ce01704g-t1.tif
where SD is the standard deviation of the blank sample, and S is the sensitivity (the slope of the fitted straight line). In Fig. 6(b, d and f), the long-term test results show that the lower detection limit of ZnO@ZIF-8 nanorod arrays remains at about 3 μM, but ZnO nanorod arrays have a higher detection limit of 50 μM due to the reduced sensitivity caused by more severe corrosion. In addition, the linear range of ZnO@ZIF-8 nanorod arrays for detecting H2O2 is 20–11[thin space (1/6-em)]550 μM. Table 1 lists the performance comparison between the prepared sensor and some previously reported sensors for detecting H2O2. Compared with other H2O2 sensors, ZnO@ZIF-8 nanoarrays show excellent performance, with advantages in sensitivity, linear range, and detection limit.

Table 1 Performance comparison between ZnO@ZIF-8 nanorods and other H2O2 sensors
Materials Linear range (μM) Limit of detection (μM) Sensitivity (μA mM−1 cm−2)
Cu2O/rGO38 30–12[thin space (1/6-em)]800 21.7 21.7 (μA mM−1)
ZnO nanorods13 10–700 42 to 143.5 2.95 × 10−4
CuO–ZnO/FTO39 10–1000 9.998 0.357 × 10−3
Ag–ZnO (ref. 40) 1–20 2.5 50.8 × 10−3
n-CoZnO (ref. 41) 0.1–2400 11.1 13.3
Cu2O/GNs42 300–7800 20.8
GNR-Fe3O4 (ref. 43) 0.5–7450 3.2 0.12
ZnO/CuO (ref. 44) 3–530 2.4 1.11 × 10−3
Graphene/ZnO (ref. 45) 1–15 mM 7.4357 3.258 (μA mM−1)
Enzyme/ZnO (ref. 46) 4.8–200 2
ZnO-LIG5 (ref. 47) 0.8–14.6 mM 110
vG/NRs-F48 2–15 mM 320 39.6
ZnO@ZIF-8 20–11[thin space (1/6-em)]550 3 4.77
(This work)


3.3 The electrochemical detection mechanism of H2O2 on ZnO@ZIF-8 nanorods

The mechanism of ZnO@ZIF-8 nanorods for detecting hydrogen peroxide is shown in Fig. 7. With the continuous dropping of H2O2, the detection mechanism of ZnO@ZIF-8 nanorods can be understood by the following reaction:13,49,50
O2(dissolved) → O2(absorbed)

O2(absorbed) + e → O2(absorbed)

2H2O2 + O2 → 2H2O + 2O2 + e

According to Fig. 7 and the above reactions, dissolved oxygen molecules are chemically adsorbed onto the surface of the nanorods by attracting the electrons in the conduction band to form ionized oxygen species, resulting in a decrease in the charge carrier density.13,51 The chemically adsorbed oxygen species (O2) will form an electron depletion layer and a high barrier near the surface area, resulting in an increase in the resistance of the materials. However, when H2O2 molecules are added to the electrolyte, the redox reaction between the H2O2 molecules and the oxygen adsorbed on the surface will release electrons to the sensing material, thereby reducing the electron depletion layer and potential barrier.13 Subsequently, due to the increase of electrons in the conduction band, the sensing material will assume a low resistance state, thereby increasing the current signal.52 In the ZnO@ZIF-8 sensor, adsorbed oxygen can be regarded as a reactive oxygen species, which can act as an active center for unpaired electrons in ZnO@ZIF-8, resulting in more H2O2 molecules adsorbing onto the surface and facilitating subsequent redox reactions. In addition, due to the coating of ZIF-8, ZnO@ZIF-8 (55.56%) has more adsorbed oxygen than ZnO (48.83%), thus more H2O2 molecules can undergo redox reactions, which can increase the current signal more sensitively. Therefore, in the first chronoamperometry test, the high-impedance ZnO@ZIF-8 still has a sensitivity similar to that of the low-impedance ZnO at a lower potential of 0.6 V.


image file: d1ce01704g-f7.tif
Fig. 7 Sensing mechanism of ZnO@ZIF-8 nanorod arrays.

3.4 Selectivity and stability

As is known, many species such as AA, DA, UA and some carbohydrates will produce interference signals in the process of detecting H2O2, which makes the selectivity of H2O2 sensors a huge challenge.15,53 As shown in Fig. 8, the anti-interference study of ZnO@ZIF-8 nanorod arrays is carried out by recording the current response of continuous injection of DA, AA, UA, GO, lysine and NaCl. Due to the suitable pore size and shape of ZIF-8, H2O2 molecules can pass through the ZIF-8 shell, but some larger molecules have difficulty passing through.54 There is an obvious current response when H2O2 is dropped, but with continuous dropping of DA, AA, UA, GO, lysine and NaCl, no obvious current response is observed, and the relative error is less than ±15%. This shows that these interfering substances will not affect the detection of H2O2 by the prepared electrode materials.
image file: d1ce01704g-f8.tif
Fig. 8 Amperometric response of ZnO@ZIF-8 nanorod arrays to the addition of 0.3 mM H2O2 or 0.1 mM other interferents in PBS (0.1 M, pH = 7.0) at an applied potential of 0.6 V.

In order to verify whether ZnO nanorods and ZnO@ZIF-8 nanorods are corroded during long-term H2O2 testing, we performed TEM on the ZnO nanorods and ZnO@ZIF-8 nanorods after H2O2 testing. As shown in Fig. 9(a), compared with the previously measured TEM image of the ZnO nanorod, after long-term detection of H2O2, the surface of the ZnO nanorod has been severely corroded. We infer that the ZnO nanorod reacts with H2O2 in the process of detecting H2O2 to generate Zn2+ ions that can be dissolved in the electrolyte. As a result, the specific surface area of the ZnO nanorod decreased, the available adsorption sites for H2O2 decreased, and the number of conduction centers decreased, which led to a decrease in the electrons responsible for conduction, thereby reducing the sensitivity of the sensor. At the same time, Lv's report shows that the presence of phosphate in PBS can significantly change the morphology of nano-zinc oxide, the surface of ZnO is significantly corroded, and nano-ZnO changes from ZnO to zinc phosphate over time.55 However, in Fig. 9(b), it can be seen that there is almost no morphological change in the ZnO cores. This is because compared with ZnO nanorods, ZnO@ZIF-8 nanorods have a ZIF-8 shell and discrete Zn nodes. These Zn nodes will be oxidized by H2O2 from Zn1+ to Zn2+ to protect ZnO from reacting with H2O2.56 Therefore, this may also be the cause of the partial dissolution of ZIF-8 as shown in Fig. 9(b). In addition, due to the selectivity of the ZIF-8 shell, the ZnO cores also avoided contact with phosphate. Therefore, the agglomeration and corrosion of the ZnO core are significantly reduced, and the performance of the sensor is greatly improved.


image file: d1ce01704g-f9.tif
Fig. 9 TEM image of the ZnO nanorod (a) and ZnO@ZIF-8 nanorod (b) after the long-term test.

4. Conclusion

In summary, by designing a core–shell structure of ZnO@ZIF-8 nanoarrays, we clearly demonstrate the importance of MOF materials, i.e. ZIF-8, in protecting ZnO from surface corrosion to achieve extended stability in electrochemical sensors. Compared with the known H2O2 sensors, the excellent detection ability delivered by the ZnO@ZIF-8 nanoarrays have the following advantages: (i) the simplicity of the direct preparation method of ZnO@ZIF-8 nanoarrays by a hydrothermal method; (ii) the excellent stability and long life due to ZIF-8 coating to protect ZnO from corrosion; (iii) the excellent selectivity owing to the molecular sieving effect provided by ZIF-8. The results show that ZnO@ZIF-8 nanoarrays are promising electrochemical materials and may provide a new solution for constructing high-stability non-enzymatic electrochemical sensors.

Conflicts of interest

There are no conflicts to declare.

Acknowledgements

This work is financially supported by the National Natural Science Foundation of China (No. 61971252 and 51972182), the Shandong Provincial Natural Science Foundation (ZR2020JQ27 and ZR2021YQ42), and the Youth Innovation Team Project of Shandong Provincial Education Department (2020KJN015).

References

  1. N. S. Lopa, M. M. Rahman, F. Ahmed, S. C. Sutradhar, T. Ryu and W. Kim, Electrochim. Acta, 2018, 274, 49–56 CrossRef CAS.
  2. Q. Q. Jin, Z. L. Chen, Q. Chen, P. W. Yan, S. X. Zhao, J. M. Shen, L. Li, F. Guo and J. Kang, J. Hazard. Mater., 2021, 404, 124142 CrossRef CAS PubMed.
  3. J. Zhao, Y. L. Yan, L. Zhu, X. X. Li and G. X. Li, Biosens. Bioelectron., 2013, 41, 815–819 CrossRef CAS PubMed.
  4. N. Isoaho, E. Peltola, S. Sainio, J. Koskinen and T. Laurila, RSC Adv., 2018, 8, 35802–35812 RSC.
  5. Z. Lou and G. Z. Shen, Adv. Sci., 2016, 3, 1500287 CrossRef PubMed.
  6. T. T. Zhou, X. P. Liu, R. Zhang, Y. B. Wang and T. Zhang, Sens. Actuators, B, 2019, 290, 210–216 CrossRef CAS.
  7. C. M. Lou, K. Wang, H. S. Mei, J. Y. Xie, W. Zheng, X. H. Liu and J. Zhang, CrystEngComm, 2021, 23, 3654–3663 RSC.
  8. Y. S. Xu, L. L. Zheng, C. Yang, W. Zheng, X. H. Liu and J. Zhang, Sens. Actuators, B, 2020, 310, 127846 CrossRef CAS.
  9. N. Karimian and P. Ugo, Curr. Opin. Electrochem., 2019, 16, 106–116 CrossRef CAS.
  10. K. S. Ranjith, R. B. Castillo, M. Sillanpaa and R. T. R. Kumar, Appl. Catal., B, 2018, 237, 128–139 CrossRef CAS.
  11. L. L. Zheng, J. Y. Xie, X. H. Liu, C. Yang, W. Zheng and J. Zhang, ACS Appl. Mater. Interfaces, 2020, 12, 46267–46276 CrossRef CAS PubMed.
  12. W. Liu, W. T. Zhan, X. Y. Jia, Q. Liu, R. S. Chen, D. Li, Y. Huang, G. Y. Zhang and H. W. Ni, Appl. Surf. Sci., 2019, 480, 341–348 CrossRef CAS.
  13. N. H. Al-Hardan, M. A. Abdul Hamid, R. Shamsudin, N. K. Othman and L. Kar Keng, Sensors, 2016, 16, 1044 Search PubMed.
  14. X. Li, G. D. Zhu, J. L. Dou, J. M. Yang, Y. X. Ge and J. Y. Liu, Ionics, 2019, 25, 5527–5536 CrossRef CAS.
  15. S. L. Yang, N. Xia, M. Y. Li, P. P. Liu, Y. X. Wang and L. B. Qu, RSC Adv., 2019, 9, 15217–15223 RSC.
  16. M. H. Yang, C. X. Duan, X. J. Zeng, J. J. Li, C. Y. Liu, L. J. Zeng, Y. Zhang, K. Wang and H. X. Xi, Rare Met., 2021, 40, 471–477 CrossRef CAS.
  17. J. Tang, Z. Z. Hui, T. Hu, X. Cheng, J. H. Guo, Z. R. Li and H. Yu, Rare Met., 2022, 41, 189–198 CrossRef CAS.
  18. H. L. Liu, L. N. Chang, C. H. Bai, L. Y. Chen, R. Luque and Y. W. Li, Angew. Chem., Int. Ed., 2016, 55, 5019–5023 CrossRef CAS PubMed.
  19. J. J. Zhou, P. Wang, C. X. Wang, Y. T. Goh, Z. Fang, P. B. Messersmith and H. W. Duan, ACS Nano, 2015, 9, 6951–6960 CrossRef CAS PubMed.
  20. M. Saikia, D. Bhuyan and L. Saikia, New J. Chem., 2015, 39, 64–67 RSC.
  21. B. K. Singh, S. Lee and K. Na, Rare Met., 2020, 39, 751–766 CrossRef CAS.
  22. W. W. Zhan, Q. Kuang, J. Z. Zhou, X. J. Kong, Z. X. Xie and L. S. Zheng, J. Am. Chem. Soc., 2013, 135, 1926–1933 CrossRef CAS PubMed.
  23. W. C. Wei, Z. Liu, R. Z. Wei, G. C. Han and C. X. Liang, RSC Adv., 2020, 10, 29923–29934 RSC.
  24. M. S. Yao, W. X. Tang, G. E. Wang, B. Nath and G. Xu, Adv. Mater., 2016, 28, 5229–5234 CrossRef CAS PubMed.
  25. M. S. Yao, L. A. Cao, Y. X. Tang, G. E. Wang, R. H. Liu, P. N. Kumar, G. D. Wu, W. H. Deng, W. J. Hong and G. Xu, J. Mater. Chem. A, 2019, 7, 18397–18403 RSC.
  26. L. Tian, Y. X. Sun, H. L. Huang, X. Y. Guo, Z. H. Qiao, J. Q. Meng and C. L. Zhong, ChemistrySelect, 2020, 5, 2401–2407 CrossRef CAS.
  27. H. L. Tian, H. Q. Fan, M. M. Li and L. T. Ma, ACS Sens., 2016, 1, 243–250 CrossRef CAS.
  28. Y. W. Li, Z. H. Tao, N. Luo, G. Sun, B. Zhang, H. H. Jin, H. Bala, J. L. Cao, Z. Y. Zhang and Y. Wang, Sens. Actuators, B, 2019, 290, 607–615 CrossRef CAS.
  29. D. Tuncel and A. N. Okte, Catal. Today, 2021, 361, 191–197 CrossRef CAS.
  30. Z. S. Li, X. H. Liu, M. Zhou, S. L. Zhang, S. Z. Cao, G. L. Lei, C. M. Lou and J. Zhang, J. Hazard. Mater., 2021, 415, 125757 CrossRef CAS PubMed.
  31. M. A. Haider, X. M. Yao, A. Loblaw and A. Finelli, Can. Urol. Assoc. J., 2017, 11, E1–E7 CrossRef PubMed.
  32. L. J. Meng, C. P. Moreira de Sá and M. P. Dos Santos, Appl. Surf. Sci., 1994, 78, 57–61 CrossRef CAS.
  33. Z. S. Li, C. M. Lou, G. L. Lei, G. C. Lu, H. Y. Pan, X. H. Liu and J. Zhang, Sens. Actuators, B, 2022, 355, 131347 CrossRef CAS.
  34. C. M. Lou, C. Yang, W. Zheng, X. H. Liu and J. Zhang, Sens. Actuators, B, 2021, 329, 129218 CrossRef CAS.
  35. Y. Li, S. Xiao, W. Li, X. He, W. Fang, H. Chen, J. Ge and L. Zhao, J. Mater. Sci., 2020, 55, 7453–7463 CrossRef CAS.
  36. W. Zheng, C. Yang, Z. S. Li, J. Y. Xie, C. M. Lou, G. L. Lei, X. H. Liu and J. Zhang, Sens. Actuators, B, 2021, 329, 129127 CrossRef CAS.
  37. Y. S. Xu, W. Zheng, X. H. Liu, L. Q. Zhang, L. L. Zheng, C. Yang, N. Pinna and J. Zhang, Mater. Horiz., 2020, 7, 1519–1527 RSC.
  38. F. G. Xu, M. Deng, G. Y. Li, S. H. Chen and L. Wang, Electrochim. Acta, 2013, 88, 59–65 CrossRef CAS.
  39. S. Chabri, A. Dhara, B. Show, D. Adak, A. Sinha and N. Mukherjee, Catal. Sci. Technol., 2016, 6, 3238–3252 RSC.
  40. M. Hussain, H. Sun, S. Karim, A. Nisar, M. Khan, A. U. Haq, M. Iqbal and M. Ahmad, J. Nanopart. Res., 2016, 18, 95 CrossRef.
  41. L. Wang, T. Wu, H. Wu, J. Zhong, N. Wang and R. M. Wang, Prog. Nat. Sci.: Mater. Int., 2018, 28, 24–27 CrossRef CAS.
  42. M. M. Liu, R. Liu and W. Chen, Biosens. Bioelectron., 2013, 45, 206–212 CrossRef CAS PubMed.
  43. A. M. Munshi, D. W. Ho, M. Saunders, V. Agarwal, C. L. Raston and K. S. Iyer, Sens. Actuators, B, 2016, 235, 492–497 CrossRef CAS.
  44. S. Daemi, S. Ghasemi and A. A. Ashkarran, J. Colloid Interface Sci., 2019, 550, 180–189 CrossRef CAS PubMed.
  45. S. S. Low, M. T. T. Tan, H. S. Loh, P. S. Khiew and W. S. Chiu, Anal. Chim. Acta, 2016, 903, 131–141 CrossRef CAS PubMed.
  46. G. Zhao, J. J. Xu and H. Y. Chen, Anal. Biochem., 2006, 350, 145–150 CrossRef CAS PubMed.
  47. J. Zanoni, J. P. Moura, N. F. Santos, A. F. Carvalho, A. J. S. Fernandes, T. Monteiro, F. M. Costa, S. O. Pereira and J. Rodrigues, Chemosensors, 2021, 9, 102 CrossRef CAS.
  48. T. Hang, S. Xiao, C. Yang, X. L. Li, C. Guo, G. He, B. H. Li, C. D. Yang, H. J. Chen, F. M. Liu, S. Z. Deng, Y. Zhang and X. Xie, Sens. Actuators, B, 2019, 289, 15–23 CrossRef CAS.
  49. C. Yang, L. W. Hu, H. Y. Zhu, Y. Ling, J. H. Tao and C. X. Xu, J. Mater. Chem. B, 2015, 3, 2651–2659 RSC.
  50. Y. Cheng, R. Yuan, Y. Chai, H. Niu, Y. Cao, H. Liu, L. Bai and Y. Yuan, Anal. Chim. Acta, 2012, 745, 137–142 CrossRef CAS PubMed.
  51. M. M. Rahman and A. M. Asiri, RSC Adv., 2015, 5, 63252–63263 RSC.
  52. Y. S. Xu, L. L. Zheng, C. Yang, X. H. Liu and J. Zhang, Sens. Actuators, B, 2020, 304, 127237 CrossRef CAS.
  53. W. Gao, W. W. Tjiu, J. C. Wei and T. X. Liu, Talanta, 2014, 120, 484–490 CrossRef CAS PubMed.
  54. J. Yang, H. L. Ye, F. Q. Zhao and B. Z. Zeng, ACS Appl. Mater. Interfaces, 2016, 8, 20407–20414 CrossRef CAS PubMed.
  55. J. T. Lv, S. Z. Zhang, S. S. Wang, L. Luo, H. L. Huang and J. Zhang, Colloids Surf., A, 2014, 461, 126–132 CrossRef CAS.
  56. Y. L. Wang, P. F. Hou, Z. Wang and P. Kang, ChemPhysChem, 2017, 18, 3142–3147 CrossRef CAS PubMed.