S. R.
Parnell
*ab,
A. L.
Washington
cd,
A. J.
Parnell
c,
A.
Walsh
e,
R. M.
Dalgliesh
f,
F.
Li
b,
W. A.
Hamilton
g,
S.
Prevost
h,
J. P. A.
Fairclough
d and
R.
Pynn
bg
aFaculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands. E-mail: S.R.Parnell@tudelft.nl
bCentre for Exploration of Energy and Matter, Indiana University, Bloomington, 47408, USA
cDepartment of Physics and Astronomy, The University of Sheffield, Sheffield, S3 7RH, UK
dDepartment of Mechanical Engineering, The University of Sheffield, Sheffield, S1 3DJ, UK
eDepartment of Chemistry, The University of Sheffield, Sheffield, S3 7HF, UK
fISIS, Rutherford Appleton Laboratory, Chilton, Oxfordshire, OX11 0QX, UK
gNeutron Sciences Directorate, Oak Ridge National Laboratory, Oak Ridge, 37831, USA
hID02 Beamline, European Synchrotron Radiation Facility, F38043, Grenoble, France
First published on 17th March 2016
Stöber silica particles are used in a diverse range of applications. Despite their widespread industrial and scientific uses, information on the internal structure of the particles is non-trivial to obtain and is not often reported. In this work we have used spin-echo small angle neutron scattering (SESANS) in conjunction with ultra small angle X-ray scattering (USAXS) and pycnometry to study an aqueous dispersion of Stöber particles. Our results are in agreement with models which propose that Stöber particles have a porous core, with a significant fraction of the pores inaccessible to solvent. For samples prepared from the same master sample in a range of H2O:D2O ratio solutions we were able to model the SESANS results for the solution series assuming monodisperse, smooth surfaced spheres of radius 83 nm with an internal open pore volume fraction of 32% and a closed pore fraction of 10%. Our results are consistent with USAXS measurements. The protocol developed and discussed here shows that the SESANS technique is a powerful way to investigate particles much larger than those studied using conventional small angle scattering methods.
One of the most common and important methods of forming silica particles uses the process developed by Stöber and co-workers in the 1960's,5 which is known to give superior control over the particle size dispersity-an advantage reflected in over 8000 citations (to date) on the original paper outlining the method. The excellent uniformity which makes Stöber particles so useful also makes them suitable for more detailed structural characterisation and a number of scattering experiments have been performed on these particles – the regularity of the process even allowing small angle X-ray scattering (SAXS) and ultra small angle X-ray scattering (USAXS) measurements to be made during particle formation. These showed that the particles initially nucleate as a ramified fractal structure which then grow by aggregating silica from solution6,7 while becoming more compact as the reaction proceeds. Similar results were found more recently by Pontoni et al.8 showing nucleation from a single small particle to a size of ≈20 nm. Once fully formed, the particles have been studied in greater depth.4,9–11 Proposed particle structures have been presented by several groups with larger silica particles formed by this aggregation and clumping of much smaller particles – with radii of the order 14 nm.12 In smaller Stöber particles (a few tens of nm) however, no core–shell structure is observed, rather a heterogeneous open structure is observed.13 In most cases, the polydispersity of Stöber particles is seen to decrease with increasing reaction time and in microscopy studies this has been associated with development of a pronounced smooth particle surface (see for example ref. 14).
Whilst a significant number of studies have looked at the structure of Stöber silica, very few have looked at the porosity, although this would seem to be a necessary concomitant of the fast nucleation and slower growth model outlined above. In one study9 helium pycnometry was used to measure the Stöber silica densities, finding values initially in the range of 2.04–2.10 g cm−3 for particles in the 80–900 nm size range, approximately a density 80% of that of crystalline quartz (2.65 g cm−3). However, after rigorous washing and drying at 90 °C the measured density decreased to 1.9–1.95 g cm−3. It has been postulated that pycnometry measurements do not measure the porosity of the entire silica particles as the C18 from stearyl alcohol, which is sometimes used in the formation process, can effectively block the pores to the helium probe gas.9
In order to investigate the structure of colloidal Stöber particles we have applied the relatively new technique of spin-echo small angle neutron scattering (SESANS).15–17 Briefly SESANS uses a series of magnetic fields to encode the scattering angle information into the polarisation of a neutron beam, a more detailed description is presented in Appendix A. The structural length scale probed depends upon the applied magnetic field strength and the neutron wavelength squared. On a time of flight neutron source, where a range of wavelengths are used, this allows a corresponding range of length scales (termed spin echo length, z) to be probed simultaneously. This technique has the ability to probe both the inter-particle and intra-particle structure in suspensions of solvents, by measuring the transverse projection of the real-space Debye correlation function G(z), rather than its Fourier transform that is obtained in the more familiar technique of small angle neutron scattering (SANS). At spin echo lengths much greater than the particle radius the spin echo signal depends very simply upon the difference in scattering length density (SLD) between the particle and solution,18 allowing this difference to be determined very accurately. In this study the particles were suspended in either pure H2O or a mixture of H2O and D2O allowing the neutron contrast between the particle and solution to be changed in a predictable way and the particle density to be inferred with similar accuracy with an absolute minimum of structural assumptions or free parameters. It is also important to note that the SESANS technique allows the measurement of the total scattering in absolute terms (eqn (11) in Appendix A) and unlike other neutron techniques the structural signal is not seriously affected by incoherent (non-structural) scattering.
The SESANS technique is capable of examining much larger length scales (up to 10's of microns) than traditional SANS and is comparable in the upper range to the accessible length scales probed by ultra small angle neutron scattering (USANS).19 The approach has a major advantage over the latter technique in that it can be applied to high concentration samples, as multiple neutron scattering effects may be taken into account exactly,20 whereas USANS is a dilute solution measurement. The technique does not change the geometry of the sample, the scan ranges are determined by the applied magnetic fields and since the scattering is encoded in the beam polarisation rather than determined from angular deviations SESANS can also employ rather divergent beams, allowing efficient use of the available polarised neutron flux.
A number of different techniques were used to fully characterise the Stöber silica particles in conjunction with our primary SESANS measurements. Dynamic light scattering (DLS) was performed using a Zetasizer NanoZS (Malvern instruments) to give values for the intensity-average and number-average hydrodynamic diameters of the silica particles. Silica dispersions were analysed using disposable cuvette cells and the results were averaged over three consecutive runs. Prior to measurement the silica dispersions were diluted with deionised water (18 MΩ) and filtered through a 0.20 μm filter membrane (to remove any dust). An LM10 particle tracker (Nanosight) was used to measure the size of a large number of single particles via tracking the individual particle tracks, which act as point scatterers and move via Brownian motion. The video footage was analysed using the inbuilt particle tracking analysis software, which gave a particle hydrodynamic radius of 73 nm. DLS measurements were also used to check the polydispersity of the samples, which was measured to be 1%, suitably mono disperse for our sample requirements here (Fig. 1).
Density measurements were made using an AccuPyc 1330 helium pycnometer (Micrometrics) with a 0.1 cm3 sample cell. Our silica particles were dried for 24 h in an oven at 100 °C to produce a dry powder sample suitable for analysis. The gas pycnometer measured a density of 2.32 g cm−3 which is only 12.5 percent lower than the value for crystalline SiO2 (2.65 g cm−3) indicating Stöber particles of good quality. SANS investigations have returned a range of density values depending on sample conditions and preparation and an accepted value of good colloidal silica particles is in the region of 2.26 g cm−3.21
The SESANS measurements were performed on the Offspec instrument22 at the ISIS pulsed neutron and Muon source (Oxfordshire, UK). Once dried the samples were then dispersed into H2O and further diluted with D2O as detailed below to make the different solution volume fractions. The data was normalised to the instrumental polarisation using a blank (pure solvent) sample of the same thickness. Similar measurements were obtained on the instrument SESAME at the Low Energy Neutron Source LENS (Indiana, USA)23,24 and are detailed in Parnell et al.25 In order to conclusively check for systematic differences in the solvent scattering, a series of H2O and D2O solvent blanks were run on the SESAME instrument in SESANS mode to check for changes in instrumental polarisation. No changes were observed between pure D2O and pure H2O for blanks of 5 mm path length, confirming that, as expected, the incoherent background which normally arises from using H2O in conventional neutron scattering measurements does not affect these SESANS measurements. Here the G(z) for the samples was determined from a comparison of the spin echo signal with and without the sample (for details see Appendix A)
USAXS measurements were performed on the beamline ID02 at ESRF and SANS measurements were performed at the LENS SANS instrument. For the dilute samples necessary for USAXS measurements a sample in H2O was diluted in concentration down to a volume fraction of ≈1%. For the SANS measurements the H2O sample was dried and redispersed into D2O to reduce incoherent scattering. The redispersed sample was sonicated for 2 hours and checks were made visually to observe that the sample was fully re-dispersed.
While very accurate for measurements of overall scattering power SESANS is somewhat less sensitive to small changes in particle radius compared to other techniques such as traditional scattering methods and hence our best estimate of the Stöber particle radius is from the dilute sample measured on ID02 at the ESRF. The measured USAXS data is shown in Fig. 3 with a simulation to a hard sphere model with a radius of 83 ± 1 nm. This value was used in the SESANS modelling, although fits of similar accuracy can be obtained for R ≈ 82.5 ± 2.5 nm, however these do change the total porosity and porous fractions due to Σt being dependent on R viaeqn (4) and (11).
Finally in order to achieve information on the surface of the particles SANS was measured at LENS from a dilute (volume fraction 1.2%) sample of the same particles in D2O (Fig. 4). Fitting to the observed Porod surface scattering region at this higher Q is shown falling off into the incoherent background signal (4). The structural scattering intensity in this data falls of as the scattering vector to the power −3.90 ± 0.03, very close to the −4 expected from a perfectly smooth sharp particle surface.
Fig. 4 SANS data for a low concentration solution of Stöber silica particles in D2O. Line is fit to Porod scattering with a fractal index (n) of 3.90 ± 0.03. |
The inaccessible void structure is similar to that recently deduced from gas adsorption measurements by Li et al.10 The predicted value from SESANS of 10% inaccessible pores is close to that predicted by pycnometry of 13%. While in an earlier SESANS investigation27 no porosity changes were observed and the SLD used for the particles was in good agreement with that obtained with bulk measurements. However in this case the silica particles were also covered by a sterically stabilizing layer of polyisobutene, 4 ± 5 nm thick. This disagreement with our results could be due to differences in the method used for particle formation or the hydrophobic coating blocking the pores and resulting in only closed pores, which appears more likely.
We observed scattering from smooth surfaces, which is consistent with earlier electron microscopy14 and measured fractal indexes of Stöber particles with a long reaction time,7 unlike fractal surface previously observed by others,11,28 albeit for larger particles.
The technique can also be applied to larger Stöber particles and also to look at changes in internal pore sizes where calcination is used to seal surface pores, however the consequence of this upon the internal pore structure has yet to be investigated.29
We have also shown that SESANS can easily be used to work with hydrogenous samples without the additional complications of incoherent scattering, unlike traditional SANS experiments. Furthermore, by analysis of the asymptotic value for the polarisation at long spin echo length, we are able to easily interpret the results without complex calibration and corrections as would be required for the analysis using traditional small angle and ultra small angle techniques.
z = cBLλ2cotθ | (1) |
The SESANS method encodes the scattering angle in the polarisation of the neutron beam and the resulting change in polarisation from the scattering (P(z)) is given by;
P(z) = exp(Σt[G(z) − 1]) | (2) |
(3) |
(4) |
For a sample which scatters isotropically, G(z) is related to the neutron scattering cross section per unit volume of sample (dσ/dΩ), as measured in a conventional SANS experiment by;30
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
G(A) = α(sinA − AcosA)/A2 + β(2AsinA + (2 − A2)cosA − 2)/A3 + γ[ −a4cosA + 4((3A2 − 6)cosA + (A3 − 6A)sinA + 6)]/A5 |
α = (1 + 2ϕ)2/(1 − ϕ)4 |
β = −6ϕ(1 + ϕ/2)2/(1 − ϕ)2 |
γ = ϕα/2 |
Finally the total (single) scattering probability (Σt) for a sample of thickness t is given by;
(11) |
(12) |
The density of the particles determined from the gas pycnometer measurements is given by.
(13) |
The contrast difference defined in eqn (7) can be written in terms of the scattering length densities of the particle (ρp) and the liquid (ρl) given as;
ρp − ρl = (1 −VOpen −VClosed)ρS − (1 − VOpen)ρl | (14) |
This journal is © The Royal Society of Chemistry 2016 |