Rational design of ratiometric and lysosome-targetable AIE dots for imaging endogenous HClO in live cells

Yongxiang Hong ab, Hong Wang b, Mingju Xue b, Peisheng Zhang *bc, Wanqiang Liu b, Shu Chen b, Rongjin Zeng b, Jiaxi Cui de, Yong Gao *a and Jian Chen *b
aCollege of Chemistry and Key Laboratory of Polymeric Materials & Application Technology of Hunan Province, and Key Laboratory of Advanced Functional Polymeric Materials of College of Hunan Province, Xiangtan University, China. E-mail: gydx.1027@163.com
bKey Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, Hunan Provincial Key Laboratory of Controllable Preparation and Functional Application of Fine Polymers, Hunan Province College Key Laboratory of QSAR/QSPR, Hunan Provincial Key Lab of Advanced Materials for New Energy Storage and Conversion, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, China. E-mail: cj0066@gmail.com; pshzhang07@gmail.com
cState Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082, P. R. China
dINM-Leibniz Institute for New Materials Campus D2 2, 66123 Saarbrícken, Germany
eInstitute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China

Received 8th October 2018 , Accepted 30th November 2018

First published on 4th December 2018


Abstract

Rational design of novel ratiometric and targetable fluorescent probes for selective imaging of lysosomal hypochlorous acid (HClO) is conducive to investigating the function of HClO in pathophysiological processes. Herein, we for the first time combine 1-pyrenecarboxaldehyde (with a π–π stacking effect) and 2-methylquinoline derivatives to synthesize an aggregation-induced-emission (AIE) probe (SA-C2-PCD) for ratiometric detection of HClO in living cells. Subsequently, a kind of novel lysosome-targetable AIE dot (AIED-Lyso) with dual emission features is prepared via a simple co-precipitation of a lysosome-targeting surfactant MAA-CO720, an amphiphilic block copolymer PEO113-b-PS46 and the HClO-responsive probe (SA-C2-PCD). The free AIED-Lyso shows only strong red AIE fluorescence without addition of HClO. However, when exposed to HClO, a strong oxidizing agent, the SA-C2-PCD would release 1-pyrenecarboxaldehyde that aggregates through π–π stacking interaction in aqueous solutions, inducing a distinct fluorescence change from red to blue. Interestingly, the as-prepared AIED-Lyso displays good water dispersity, high selectivity and sensitivity (∼70.4 nM), strong anti-interference ability, prominent long-term fluorescence stability (>10 weeks), and low cytotoxicity, and it can be successfully applied to visually detect endogenous lysosomal HClO in live cells.


Introduction

Hypochlorous acid (HClO) is known as an active oxygen molecule that is mainly produced by hydrogen peroxide and chloride ions under the catalysis of myeloperoxidase (MPO) and it also plays an important role in fighting pathogenic microorganisms, resisting viruses, etc.1,2 Abnormal levels of endogenous HClO can cause a series of diseases, including Parkinson's disease, Alzheimer's disease, cancer, etc.3,4 On the other hand, lysosomes, as an acidic organelle (pH 4.5–5.5), have long been considered as a waste disposal facility in cells.5 Recent studies have shown that lysosomes possess various biological functions, including cell signal transduction, protein degradation, plasma membrane repair, homogenous stability, and autophagy, and are regarded as critical subcellular organelles.6,7 Lysosomes are one of the main HClO-producing organelles, and excess HClO can induce cell death through calpain activation and lysosomal disruption.8,9 Therefore, qualitative analysis and detection of HClO in lysosomes are of great significance.

The recently developed fluorescence method has the merits of simple operation, rapid real-time analysis, and high spatial and temporal resolution, and has received extensive attention and significant development.10–18 To date, a series of small molecule-based fluorescent probes for optically sensing HClO have been fabricated.19–22 However, most of them show a single fluorescence signal that often varies with other factors such as microenvironment, sensor concentration, photobleaching, and excitation intensity and thus the reliability could be low.23–25 In contrast, signals containing two well-resolved emissions (ratiometric) from fluorescent probes can effectively increase the accuracy.26–31 However, most of the strategies currently available are built on the use of conventional small molecule-based ratiometric probes which usually show the undesirable aggregation-induced quenching (ACQ) phenomenon in aqueous solutions, significantly confining their detection performance.32–34 In addition, the self-absorption effect of these reported conventional small fluorescent probes due to their small Stokes shift also leads to fluorescence self-annihilation.35

Currently, aggregation-induced-emission (AIE) based fluorophores, which were first developed by Tang and co-workers, are proving to be effective probes avoiding the ACQ effect.36–42 In particular, the AIE dots developed very recently are widely used as novel fluorescent probes in the field of sensing and imaging in living cancer cells due to their outstanding merits such as stable dispersity in water, large Stokes shift, intense fluorescence, prominent photostability, good biocompatibility, etc.43–47 However, to the best of our knowledge, no lysosome-targetable AIE dots for ratiometric detection of lysosomal HClO have been reported yet.

In this study, we report on the construction of lysosome-targetable AIE dots (AIED-Lyso) for ratiometric imaging of lysosomal HClO. Our AIE dots are made via a simple co-precipitation of a lysosome-targetable surfactant MAA-CO720, an amphiphilic block copolymer PEO113-b-PS46 and a HClO-responsive probe (SA-C2-PCD), as shown in Scheme 1. In our design, in the presence of strong oxidant HClO, the double bond of SA-C2-PCD would break to reduce its red AIE fluorescence and also generate 1-pyrenecarboxaldehyde. This new-born chromophore would induce a progressively enhanced blue fluorescence due to intermolecular π–π stacking interaction. The as-prepared AIED-Lyso with good biocompatibility can mainly locate in lysosomes, and monitor endogenous HClO in lysosomes.


image file: c8qm00511g-s1.tif
Scheme 1 Ratiometric imaging of endogenous HClO in lysosomes using lysosome-targetable AIE dots (AIED-Lyso).

Experimental section

Materials and instruments

All the chemical agents were purchased from commercial sources. Compound 1, compound 2 and PEO113-b-PS46 were synthesized via the protocols developed by us.48 The synthesis, apparatus, cytotoxicity and live cell imaging were as stated in the ESI.

Results and discussion

The strategy for the fabrication of AIED-Lyso

Scheme 1 depicts the strategy for fabricating AIED-Lyso. We take advantage of the prominent AIE nature of SA-C2-PCD to alternate the undesirable ACQ effect and also get a large Stokes shift (∼220 nm) for avoiding self-absorption interference. An amphiphilic block copolymer (PEO113-b-PS46) is designed to provide a hydrophobic environment by forming micelles to enhance the long-term stability, photostability, and brightness of the hydrophobic AIE dyes. When additional morpholine groups are incorporated, these micelle-based particles could serve as the targetable vehicles for specific targeting of lysosomes.

The synthesis of SA-C2-PCD and MAA-CO720 is described in Schemes S1 and S2 (ESI). All the intermediates and the final product were characterized by 1H NMR, 13C NMR and mass spectroscopy (Fig. S1–S5, ESI).

Well-dispersed AIED-Lyso was synthesized via a co-precipitation strategy (Scheme 1) in which all these components were dissolved in THF at first and then co-precipitated in water to form nanoparticles. The core of the nanoparticles is composed of hydrophobic compositions including SA-C2-PCD, PS, and nonylphenyl groups, while the shell is made from hydrophilic PEO groups. In this structure, the morphoyl terminal groups can not only improve water solubility, but also specifically locate at lysosomes. The obtained AIED-Lyso are spherical with an average diameter of 30 nm (checked by transmission electron microscope (TEM) and dynamic light scattering (DLS), Fig. 1A and B). For the fluorescence long-term stability test, the diluted AIED-Lyso dispersion was sealed and stored in the dark under an ambient temperature. Then an aliquot was drawn out for the fluorescence test every week. As shown in Fig. S6 (ESI), the fluorescence intensity ratio (F475/F620) of the diluted AIED-Lyso sample without and with HClO changed seldom even after storing for 10 weeks, implying its remarkable long-term stability of fluorescence. In addition, the average diameter of the AIED-Lyso dispersion at different time slots was provided (Fig. S7, ESI). No obvious size changes in the AIED-Lyso dispersion were observed even after storing for 10 weeks, indicating the admirable stability of our nanoprobe.


image file: c8qm00511g-f1.tif
Fig. 1 (A) TEM image of AIED-Lyso; (B) size of AIED-Lyso determined by DLS.

Ratiometric detection of HClO

We first tested the fluorescence of SA-C2-PCD under different conditions (THF/water mixture) to confirm its AIE property (Fig. S8, ESI). In THF, a good solvent for SA-C2-PCD, no visible fluorescence was observed. When water was added to induce aggregation, the relative emission intensity (F0/F) of SA-C2-PCD gradually increased at first (water fractions fw < 80 vol%) and then jumped at fw > 80 vol%, showing a F0/F of 198 at fw = 95 vol%, indicating a typical AIE effect.

We then investigated the responsiveness of AIED-Lyso to HClO. Note that AIED-Lyso itself exhibited an obvious absorption peak at 440 nm in the solution state. When HClO was added, the peak at 440 nm gradually declined, accompanied by the formation of an increasing new absorption peak centered at 350 nm (Fig. S9, ESI). Simultaneously, as shown in Fig. 2A and B (Fig. S10, ESI), obvious blue-shift from 620 nm to 475 nm was observed in the emission spectra, suggesting a reliable ratiometric detection mode. Moreover, the fluorescence intensity ratio (F475/F620) varies linearly with HClO concentration (0–5 μM) with a detection limit of 70.4 nM (Fig. S11, ESI).


image file: c8qm00511g-f2.tif
Fig. 2 (A) Fluorescence response of AIED-Lyso (2.67 μg mL−1) towards different concentrations of HClO (0–20 μM, λex = 399 nm); (B) the fluorescence intensity ratio (F475/F620) as a function of HClO concentration (0–20 μM); (C) the fluorescence intensity ratio (F475/F620) as a function of time; and (D) the fluorescence intensity ratio (F475/F620) without and with HClO (20 μM) as a function of pH.

Fig. 2C shows the time response of the nanoprobe toward HClO. The F475/F620 ratio changed after HClO was added into the AIED-Lyso solution for only one min, implying a rapid detection feature. Fig. 2D describes the effect of pH on the fluorescence intensity ratio (F475/F620) in the absence and presence of HClO. Without HClO, AIED-Lyso exhibits good stability from pH 3.0 to 9.0. In contrast, the addition of HClO (20 μM) induces an obvious enhancement of F475/F620 from pH 3.0 to 6.0, suggesting the wide adaptive range of AIED-Lyso in acidic environments including lysosomes.

To evaluate the selectivity of AIED-Lyso, the F475/F620 ratio of AIED-Lyso solution was examined in the presence of HClO or other biologically relevant molecules including anions, reactive oxygen species (ROS) and thiols (Fig. 3A). Except for HClO, other biologically relevant molecules did not induce obvious variation in F475/F620. Moreover, a negligible interfering effect on the F475/F620 ratio of AIED-Lyso was found when HClO and other biologically relevant molecules were added together (Fig. 3B). All these results indicated that AIED-Lyso can selectively detect HClO in complex biological environments.


image file: c8qm00511g-f3.tif
Fig. 3 (A) Fluorescence intensity ratio (F475/F620) for AIED-Lyso (2.67 μg mL−1) in the presence of 20 μM HClO or one biologically relevant molecule; (B) fluorescence intensity ratio (F475/F620) for AIED-Lyso (2.67 μg mL−1) in the presence of 20 μM of HClO and one biologically relevant molecule; note: (1–18[thin space (1/6-em)]:[thin space (1/6-em)]200 μM, 19–20[thin space (1/6-em)]:[thin space (1/6-em)]5.0 mM, 21–25[thin space (1/6-em)]:[thin space (1/6-em)]200 μM) 1, Na+; 2, K+; 3, Ca2+; 4, Zn2+; 5, Co2+; 6, Cu2+; 7, Mg2+; 8, Fe3+; 9, Fe2+; 10, Ni2+; 11, Cl; 12, SO42−; 13, NO3; 14, H2PO4; 15, HPO42−; 16, PO43−; 17, SO32−; 18, NO2; 19, Cys; 20, GSH; 21, H2O2; 22, NO; 23, 1O2; 24, HO; 25, t-BuO. λex = 399 nm.

On the basis of the fluorescent response of SA-C2-PCD toward HClO, we anticipated that the strongly oxidized HClO can first oxidize the double bond between the SA-C2 moiety and pyrene moiety, then gradually hydrolyze into SA-C2-CHO and pyrene-CHO (Scheme S3, ESI). The newly produced pyrene-CHO would form excimers in aqueous solution.27 Therefore, the change in the F475/F620 ratio can be linked to the response of SA-C2-PCD toward HClO, as shown in Fig. 2A. This proposed response mechanism was further confirmed by MS measurements. As expected, the mass peak at 730.4 m/z which corresponds to the nanoprobe SA-C2-PCD was replaced by mass peaks at 531.3 m/z and 231.1 m/z that correspond to SA-C2-CHO and pyrene-CHO, respectively (Fig. S12A and B, ESI). These results supported the proposed reaction mechanism (Scheme S3, ESI).

Imaging exogenous and endogenous HClO levels in living cells

We firstly evaluated the cytotoxicity of AIED-Lyso with representative HeLa cells (Fig. S13, ESI). Positive results indicated minimal cytotoxicity and our AIED-Lyso should be suitable for intracellular HClO sensing.

It has been well documented that small molecule-based probes with a morpholine moiety mainly accumulate in lysosomes;21,49 meanwhile, the intracellular uptake of nanoparticles is generally performed by the endocytosis strategy and they are often located in lysosomes.50–53 To increase the lysosomal targeting ability, we introduce morpholine groups onto the surface of the nanoparticles to sense HClO in lysosomes. To conduct the colocalization studies, HeLa cells were treated with both AIED-Lyso and LysoTracker Green (a commercial lysosomal tracker), and the results are given in Fig. 4. The red emission of AIED-Lyso fully overlapped with the green fluorescence of LysoTracker Green and the Pearson's R value was calculated to be 0.96 between our nanoprobe (shown in Red channel) and LysoTracker Green (shown in Green channel), which is far beyond the threshold of >0.5 required for correlation, indicating that AIED-Lyso mainly localized in lysosomes and can specifically monitor HClO in lysosomes.


image file: c8qm00511g-f4.tif
Fig. 4 Images of HeLa cells co-incubated with (A) AIED-Lyso (2.67 μg mL−1; λex = 405 nm, and λem = 575–675 nm) and (B) LysoTracker Green (500 nM; λex = 468 nm, and λem = 500–520 nm); (C) the merged image of (A and B); (D) the intensity profile of ROI across HeLa cells from the red and green channels; and (E) the correlation plot of two channels. Scale bar: 20 μm.

AIED-Lyso was subsequently used for ratiometric imaging of exogenous HClO levels in HeLa cells. As shown in Fig. 5, HeLa cells treated with only AIED-Lyso provide strong red fluorescence and a low ratio of emission intensity (blue/red) (Fig. 5E, I and M). When the cells pre-treated with AIED-Lyso were exposed to different concentrations of HClO (10 μM, 20 μM and 30 μM), the blue fluorescence was obviously enhanced (Fig. 5J, K and L), accompanied by a decrease in red fluorescence (Fig. 5F, G and H). Accordingly, the ratio of emission intensity (blue/red) is also significantly enhanced (Fig. 5N, O and P). These results suggest that AIED-Lyso can be applied for ratiometric imaging of exogenous HClO in living cells. It was noted that the living cells were complicated systems, and the intracellular uptake of HClO was lower than the initial concentration. In addition, the intracellular reducing substances (e.g. GSH) can consume some of the HClO. Thus, a relatively high HClO concentration (10–30 μM) was applied to the cells in order to make the nanoprobe facile for ratiometric imaging of exogenous HClO levels in HeLa cells.


image file: c8qm00511g-f5.tif
Fig. 5 Fluorescence images of HeLa cells treated with AIED-Lyso (2.67 μg mL−1) with the addition of 0 (control), 10 μM, 20 μM and 30 μM HClO (from the left column to the right column). The ratio images were all obtained as Fblue/Fred. λex = 405 nm, λem1 = 425–525 nm (blue channel), and λem2 = 575–675 nm (red channel), scale bar = 20 μm.

Finally, we imaged endogenous HClO in living cells. It has been well documented that endogenous HClO can be produced from RAW264.7 cells by treating them with lipopolysaccharide (LPS) and phorbol myristate acetate (PMA).54,55 As illustrated in Fig. 6, the RAW264.7 cells incubated with only AIED-Lyso showed bright red fluorescence with a low ratio of emission intensity (blue/red) (Fig. 6D, G and J). After stimulating with LPS and PMA, the RAW264.7 cells treated with AIED-Lyso revealed an obvious decrease in red fluorescence but a significant enhancement in blue fluorescence with a high ratio of emission intensity (blue/red) (Fig. 6E, H and K). To further confirm that the intracellular fluorescence emission changes were triggered by the endogenous HClO, N-acetylcysteine (NAC) was added as an effective ROS scavenger to reduce the cellular HClO level.56,57 As shown in Fig. 6F, I and L, when the RAW264.7 cells were incubated with LPS, PMA and NAC, the blue fluorescence was suppressed, whereas the red fluorescence was recovered to some extent. The above results demonstrated that AIED-Lyso can serve as a ratiometric nanoprobe to visualize the endogenously generated HClO in RAW264.7 cells.


image file: c8qm00511g-f6.tif
Fig. 6 Fluorescence microscopy images of RAW264.7 cells. The control groups (A, D and G) are incubated with AIED-Lyso (2.67 μg mL−1) for 3 h. The cells in groups (B, E, and H) are first incubated with LPS (1 μg mL−1) for 12 h, followed by coincubation with PMA (1 μg mL−1) and AIED-Lyso (2.67 μg mL−1) for 3 h. The cells in groups (C, F, and I) are first incubated with LPS (1 μg mL−1) and NAC (2 mM) for 12 h, followed by coincubation with PMA (1 μg mL−1) and AIED-Lyso (2.67 μg mL−1) for 3 h. The ratio image is obtained as the ratio of blue fluorescence intensity to red fluorescence intensity (Fblue/Fred) (J, K and L). λex = 405 nm, λem1 = 425–525 nm (blue channel), and λem2 = 575–675 nm (red channel), scale bar = 20 μm.

Conclusions

In summary, a novel lysosome-targetable and ratiometric nanoprobe (AIED-Lyso) was rationally designed and synthesized for selectively sensing exogenous and endogenous HClO levels in live cells. The results indicated that AIED-Lyso possessed stable water dispersity, high selectivity, excellent long-term fluorescence stability (>10 weeks), and good biocompatibility. Importantly, with the aid of the lysosomal targeting group, AIED-Lyso can mainly accumulate in lysosomes and then monitor the exogenous and endogenous HClO in live cells. The design of the lysosome-targetable and ratiometric fluorescent nanoprobe presented herein should provide a new avenue for exploring the function of HClO-associated diseases.

Conflicts of interest

The authors declare no competing financial interest.

Acknowledgements

The present work was financially supported by the NSFC (Project no. 51773056, 51603067, 51873058, 21574112, 2147204), Hunan Provincial Natural Science Foundation of China (No. 2018JJ3143), China Postdoctoral Science Foundation (2017M622571 and 2018T110824), Open Project Program of State Key Laboratory of Chemo/Biosensing and Chemometrics (Project no. 2016019) and Open Project Program of Key Laboratory for High Performance and Functional Polymer Materials of Guangdong Province (South China University of Technology) (Project no. 20160005).

Notes and references

  1. Z. M. Prokopowicz, F. Arce, R. Biedron, C. L.-L. Chiang, M. Ciszek, D. R. Katz, M. Nowakowska, S. Zapotoczny, J. Marcinkiewicz and B. M. Chain, J. Immunol., 2010, 184, 824–835 CrossRef CAS PubMed.
  2. Y. W. Yap, M. Whiteman and N. S. Cheung, Cell. Signalling, 2007, 19, 219–228 CrossRef CAS.
  3. M. Singh, M. Arseneault, T. Sanderson, V. Murthy and C. Ramassamy, J. Agric. Food Chem., 2008, 56, 4855–4873 CrossRef CAS.
  4. M. J. Steinbeck, L. J. Nesti, P. F. Sharkey and J. Parvizi, J. Orthop. Res., 2007, 25, 1128–1135 CrossRef CAS.
  5. G. Kroemer and M. Jäättelä, Nat. Rev. Cancer, 2005, 5, 886 CrossRef CAS PubMed.
  6. F. Yu, Z. Chen, B. Wang, Z. Jin, Y. Hou, S. Ma and X. Liu, Tumor Biol., 2016, 37, 1427–1436 CrossRef CAS PubMed.
  7. P. R. Pryor and J. P. Luzio, Biochim. Biophys. Acta, Mol. Cell Res., 2009, 1793, 615–624 CrossRef CAS PubMed.
  8. S. J. Klebanoff, J. Leukocyte Biol., 2005, 77, 598–625 CrossRef CAS PubMed.
  9. L. Yuan, L. Wang, B. K. Agrawalla, S. Park, H. Zhu, B. Sivaraman, J. Peng, Q. Xu and Y. Chang, J. Am. Chem. Soc., 2015, 137, 5930–5938 CrossRef CAS PubMed.
  10. X. Li, X. Gao, W. Shi and H. Ma, Chem. Rev., 2014, 114, 590–659 CrossRef CAS.
  11. Y. Yang, Q. Zhao, W. Feng and F. Li, Chem. Rev., 2013, 113, 192–270 CrossRef CAS.
  12. P. Zhang, Y. Tian, H. Liu, J. Ren, H. Wang, R. Zeng, Y. Long and J. Chen, Chem. Commun., 2018, 54, 7231–7234 RSC.
  13. M. Gao, F. Yu, C. Lv, J. Choo and L. Chen, Chem. Soc. Rev., 2017, 46, 2237–2271 RSC.
  14. L. He, B. Dong, Y. Liu and W. Lin, Chem. Soc. Rev., 2016, 45, 6449–6461 RSC.
  15. V. S. Lin, W. Chen, M. Xian and C. J. Chang, Chem. Soc. Rev., 2015, 44, 4596–4618 RSC.
  16. F. Gouanvé, T. Schuster, E. Allard, R. Méallet-Renault and C. Larpent, Adv. Funct. Mater., 2007, 17, 2746–2756 CrossRef.
  17. P. Zhang, X. F. Jiang, X. Nie, Y. Huang, F. Zeng, X. Xia and S. Wu, Biomaterials, 2016, 80, 46–56 CrossRef CAS PubMed.
  18. X. P. He, X. L. Hu, T. D. James, J. Yoon and H. Tian, Chem. Soc. Rev., 2017, 46, 6687–6696 RSC.
  19. X. Jiao, Y. Li, J. Niu, X. Xie, X. Wang and B. Tang, Anal. Chem., 2018, 90, 533–555 CrossRef CAS PubMed.
  20. X. Chen, F. Wang, J. Y. Hyun, T. Wei, J. Qiang, X. Ren, I. Shin and J. Yoon, Chem. Soc. Rev., 2016, 45, 2976–3016 RSC.
  21. M. Ren, K. Zhou, L. He and W. Lin, J. Mater. Chem. B, 2018, 6, 1716–1733 RSC.
  22. M. H. Lee, J. S. Kim and J. L. Sessler, Chem. Soc. Rev., 2015, 44, 4185–4191 RSC.
  23. H. Zhu, J. Fan, J. Wang, H. Mu and X. Peng, J. Am. Chem. Soc., 2014, 136, 12820–12823 CrossRef CAS PubMed.
  24. W. Chen, A. Pacheco, Y. Takano, J. J. Day, K. Hanaoka and M. Xian, Angew. Chem., Int. Ed., 2016, 55, 9993–9996 CrossRef CAS PubMed.
  25. W. Chen, E. W. Rosser, T. Matsunaga, A. Pacheco, T. Akaike and M. Xian, Angew. Chem., Int. Ed., 2015, 54, 13961–13965 CrossRef CAS PubMed.
  26. X. Zhang, W. Zhao, B. Li, W. Li, C. Zhang, X. Hou, J. Jiang and Y. Dong, Chem. Sci., 2018, 9, 8207–8212 RSC.
  27. Y. Wu, J. Wang, F. Zeng, S. Huang, J. Huang, H. Xie, C. Yu and S. Wu, ACS Appl. Mater. Interfaces, 2016, 8, 1511–1519 CrossRef CAS.
  28. M. Xue, H. Wang, J. Chen, J. Ren, S. Chen, H. Yang, R. Zeng, Y. Long and P. Zhang, Sens. Actuators, B, 2018, 282, 1–9 CrossRef.
  29. Y. Huang, P. Zhang, M. Gao, F. Zeng, A. Qin, S. Wu and B. Z. Tang, Chem. Commun., 2016, 52, 7288–7291 RSC.
  30. J. Chen, C. Zhang, K. Lv, H. Wang, P. Zhang, P. Yi and J. Jiang, Sens. Actuators, B, 2017, 251, 533–541 CrossRef CAS.
  31. S. Shen, X. Zhao, X. Zhang, X. Liu, H. Wang, Y. Dai, J. Miao and B. Zhao, J. Mater. Chem. B, 2017, 5, 289–295 RSC.
  32. H. Wang, P. Zhang, Y. Hong, B. Zhao, P. Yi and J. Chen, Polym. Chem., 2017, 8, 5795–5802 RSC.
  33. P. Zhang, H. Wang, D. Zhang, X. Zeng, R. Zeng, L. Xiao, H. Tao, Y. Long, P. Yi and J. Chen, Sens. Actuators, B, 2018, 255, 2223–2231 CrossRef CAS.
  34. P. Zhang, H. Wang, Y. Hong, M. Yu, R. Zeng, Y. Long and J. Chen, Biosens. Bioelectron., 2018, 99, 318–324 CrossRef CAS.
  35. P. Zhang, X. Nie, M. Gao, F. Zeng, A. Qin, S. Wu and B. Z. Tang, Mater. Chem. Front., 2017, 1, 838–845 RSC.
  36. J. Liang, B. Z. Tang and B. Liu, Chem. Soc. Rev., 2015, 44, 2798–2811 RSC.
  37. J. Qian and B. Z. Tang, Chemistry, 2017, 3, 56–91 CrossRef CAS.
  38. D. Ding, K. Li, B. Liu and B. Z. Tang, Acc. Chem. Res., 2013, 46, 2441–2453 CrossRef CAS.
  39. H. Li, J. Chang, T. Hou and F. Li, J. Mater. Chem. B, 2016, 4, 198–201 RSC.
  40. W. Zhong, X. Zeng, J. Chen, Y. Hong, L. Xiao and P. Zhang, Polym. Chem., 2017, 8, 4849–4855 RSC.
  41. Z. Guo, A. Shao and W.-H. Zhu, J. Mater. Chem. C, 2016, 4, 640–2646 Search PubMed.
  42. A. Shao, Y. Xie, S. Zhu, Z. Guo, S. Zhu, J. Guo, P. Shi, T. D. James, H. Tian and W. H. Zhu, Angew. Chem., Int. Ed., 2015, 54, 7275–7280 CrossRef CAS PubMed.
  43. X. Zhang, K. Wang, M. Liu, X. Zhang, L. Tao, Y. Chen and Y. Wei, Nanoscale, 2015, 7, 11486–11508 RSC.
  44. D. Wang, J. Qian, W. Qin, A. Qin, B. Z. Tang and S. He, Sci. Rep., 2014, 4, 4279 CrossRef PubMed.
  45. G. Feng, W. Wu, S. Xu and B. Liu, ACS Appl. Mater. Interfaces, 2016, 8, 21193–21200 CrossRef CAS PubMed.
  46. Q. Ye, S. Chen, D. Zhu, X. Lu and Q. Lu, J. Mater. Chem. B, 2015, 3, 3091–3097 RSC.
  47. K. Li, Z. Zhu, P. Cai, R. Liu, N. Tomczak, D. Ding, J. Liu, W. Qin, Z. Zhao, Y. Hu, X. Chen, B. Z. Tang and B. Liu, Chem. Mater., 2013, 25, 4181–4187 CrossRef CAS.
  48. P. Zhang, Y. Hong, H. Wang, M. Yu, Y. Gao, R. Zeng, Y. Long and J. Chen, Polym. Chem., 2017, 8, 7271–7278 RSC.
  49. W. Xu, Z. Zeng, J.-H. Jiang, Y.-T. Chang and L. Yuan, Angew. Chem., Int. Ed., 2016, 55, 13658–13699 CrossRef CAS PubMed.
  50. C. Zhu, D. Huo, Q. Chen, J. Xue, S. Shen and Y. Xia, Adv. Mater., 2017, 1703702 CrossRef PubMed.
  51. F. Du, Y. Ming, F. Zeng, C. Yu and S. Wu, Nanotechnology, 2013, 24, 365101 CrossRef PubMed.
  52. X. Ma, Y. Wu, S. Jin, Y. Tian, X. Zhang, Y. Zhao, L. Yu and X.-J. Liang, ACS Nano, 2011, 5, 8629–8639 CrossRef CAS PubMed.
  53. Y. Hong, P. Zhang, H. Wang, M. Yu, Y. Gao and J. Chen, Sens. Actuators, B, 2018, 272, 340–347 CrossRef CAS.
  54. Y. Koide, Y. Urano, K. Hanaoka, T. Terai and T. Nagano, J. Am. Chem. Soc., 2011, 133, 5680–5682 CrossRef CAS PubMed.
  55. W. Zhang, W. Liu, P. Li, J. Kang, J. Wang, H. Wang and B. Tang, Chem. Commun., 2015, 51, 10150–10153 RSC.
  56. Z. Zhan, R. Liu, L. Chai, Q. Li, K. Zhang and Y. Lv, Anal. Chem., 2017, 89, 9544–9551 CrossRef CAS PubMed.
  57. Y. W. Jun, S. Sarkar, S. Singha, Y. J. Reo, H. R. Kim, J. Kim, Y. Chang and K. H. Ahn, Chem. Commun., 2017, 53, 10800–10803 RSC.

Footnote

Electronic supplementary information (ESI) available: Synthesis procedures, 1H NMR spectra, 13C NMR, MS, absorption spectrum, fluorescence spectra, AIE behaviour, detection limit, cell viability, etc. See DOI: 10.1039/c8qm00511g

This journal is © the Partner Organisations 2019