Yongxiang
Hong
ab,
Hong
Wang
b,
Mingju
Xue
b,
Peisheng
Zhang
*bc,
Wanqiang
Liu
b,
Shu
Chen
b,
Rongjin
Zeng
b,
Jiaxi
Cui
de,
Yong
Gao
*a and
Jian
Chen
*b
aCollege of Chemistry and Key Laboratory of Polymeric Materials & Application Technology of Hunan Province, and Key Laboratory of Advanced Functional Polymeric Materials of College of Hunan Province, Xiangtan University, China. E-mail: gydx.1027@163.com
bKey Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, Hunan Provincial Key Laboratory of Controllable Preparation and Functional Application of Fine Polymers, Hunan Province College Key Laboratory of QSAR/QSPR, Hunan Provincial Key Lab of Advanced Materials for New Energy Storage and Conversion, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, China. E-mail: cj0066@gmail.com; pshzhang07@gmail.com
cState Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082, P. R. China
dINM-Leibniz Institute for New Materials Campus D2 2, 66123 Saarbrícken, Germany
eInstitute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu, Sichuan 610054, China
First published on 4th December 2018
Rational design of novel ratiometric and targetable fluorescent probes for selective imaging of lysosomal hypochlorous acid (HClO) is conducive to investigating the function of HClO in pathophysiological processes. Herein, we for the first time combine 1-pyrenecarboxaldehyde (with a π–π stacking effect) and 2-methylquinoline derivatives to synthesize an aggregation-induced-emission (AIE) probe (SA-C2-PCD) for ratiometric detection of HClO in living cells. Subsequently, a kind of novel lysosome-targetable AIE dot (AIED-Lyso) with dual emission features is prepared via a simple co-precipitation of a lysosome-targeting surfactant MAA-CO720, an amphiphilic block copolymer PEO113-b-PS46 and the HClO-responsive probe (SA-C2-PCD). The free AIED-Lyso shows only strong red AIE fluorescence without addition of HClO. However, when exposed to HClO, a strong oxidizing agent, the SA-C2-PCD would release 1-pyrenecarboxaldehyde that aggregates through π–π stacking interaction in aqueous solutions, inducing a distinct fluorescence change from red to blue. Interestingly, the as-prepared AIED-Lyso displays good water dispersity, high selectivity and sensitivity (∼70.4 nM), strong anti-interference ability, prominent long-term fluorescence stability (>10 weeks), and low cytotoxicity, and it can be successfully applied to visually detect endogenous lysosomal HClO in live cells.
The recently developed fluorescence method has the merits of simple operation, rapid real-time analysis, and high spatial and temporal resolution, and has received extensive attention and significant development.10–18 To date, a series of small molecule-based fluorescent probes for optically sensing HClO have been fabricated.19–22 However, most of them show a single fluorescence signal that often varies with other factors such as microenvironment, sensor concentration, photobleaching, and excitation intensity and thus the reliability could be low.23–25 In contrast, signals containing two well-resolved emissions (ratiometric) from fluorescent probes can effectively increase the accuracy.26–31 However, most of the strategies currently available are built on the use of conventional small molecule-based ratiometric probes which usually show the undesirable aggregation-induced quenching (ACQ) phenomenon in aqueous solutions, significantly confining their detection performance.32–34 In addition, the self-absorption effect of these reported conventional small fluorescent probes due to their small Stokes shift also leads to fluorescence self-annihilation.35
Currently, aggregation-induced-emission (AIE) based fluorophores, which were first developed by Tang and co-workers, are proving to be effective probes avoiding the ACQ effect.36–42 In particular, the AIE dots developed very recently are widely used as novel fluorescent probes in the field of sensing and imaging in living cancer cells due to their outstanding merits such as stable dispersity in water, large Stokes shift, intense fluorescence, prominent photostability, good biocompatibility, etc.43–47 However, to the best of our knowledge, no lysosome-targetable AIE dots for ratiometric detection of lysosomal HClO have been reported yet.
In this study, we report on the construction of lysosome-targetable AIE dots (AIED-Lyso) for ratiometric imaging of lysosomal HClO. Our AIE dots are made via a simple co-precipitation of a lysosome-targetable surfactant MAA-CO720, an amphiphilic block copolymer PEO113-b-PS46 and a HClO-responsive probe (SA-C2-PCD), as shown in Scheme 1. In our design, in the presence of strong oxidant HClO, the double bond of SA-C2-PCD would break to reduce its red AIE fluorescence and also generate 1-pyrenecarboxaldehyde. This new-born chromophore would induce a progressively enhanced blue fluorescence due to intermolecular π–π stacking interaction. The as-prepared AIED-Lyso with good biocompatibility can mainly locate in lysosomes, and monitor endogenous HClO in lysosomes.
Scheme 1 Ratiometric imaging of endogenous HClO in lysosomes using lysosome-targetable AIE dots (AIED-Lyso). |
The synthesis of SA-C2-PCD and MAA-CO720 is described in Schemes S1 and S2 (ESI†). All the intermediates and the final product were characterized by 1H NMR, 13C NMR and mass spectroscopy (Fig. S1–S5, ESI†).
Well-dispersed AIED-Lyso was synthesized via a co-precipitation strategy (Scheme 1) in which all these components were dissolved in THF at first and then co-precipitated in water to form nanoparticles. The core of the nanoparticles is composed of hydrophobic compositions including SA-C2-PCD, PS, and nonylphenyl groups, while the shell is made from hydrophilic PEO groups. In this structure, the morphoyl terminal groups can not only improve water solubility, but also specifically locate at lysosomes. The obtained AIED-Lyso are spherical with an average diameter of 30 nm (checked by transmission electron microscope (TEM) and dynamic light scattering (DLS), Fig. 1A and B). For the fluorescence long-term stability test, the diluted AIED-Lyso dispersion was sealed and stored in the dark under an ambient temperature. Then an aliquot was drawn out for the fluorescence test every week. As shown in Fig. S6 (ESI†), the fluorescence intensity ratio (F475/F620) of the diluted AIED-Lyso sample without and with HClO changed seldom even after storing for 10 weeks, implying its remarkable long-term stability of fluorescence. In addition, the average diameter of the AIED-Lyso dispersion at different time slots was provided (Fig. S7, ESI†). No obvious size changes in the AIED-Lyso dispersion were observed even after storing for 10 weeks, indicating the admirable stability of our nanoprobe.
We then investigated the responsiveness of AIED-Lyso to HClO. Note that AIED-Lyso itself exhibited an obvious absorption peak at 440 nm in the solution state. When HClO was added, the peak at 440 nm gradually declined, accompanied by the formation of an increasing new absorption peak centered at 350 nm (Fig. S9, ESI†). Simultaneously, as shown in Fig. 2A and B (Fig. S10, ESI†), obvious blue-shift from 620 nm to 475 nm was observed in the emission spectra, suggesting a reliable ratiometric detection mode. Moreover, the fluorescence intensity ratio (F475/F620) varies linearly with HClO concentration (0–5 μM) with a detection limit of 70.4 nM (Fig. S11, ESI†).
Fig. 2C shows the time response of the nanoprobe toward HClO. The F475/F620 ratio changed after HClO was added into the AIED-Lyso solution for only one min, implying a rapid detection feature. Fig. 2D describes the effect of pH on the fluorescence intensity ratio (F475/F620) in the absence and presence of HClO. Without HClO, AIED-Lyso exhibits good stability from pH 3.0 to 9.0. In contrast, the addition of HClO (20 μM) induces an obvious enhancement of F475/F620 from pH 3.0 to 6.0, suggesting the wide adaptive range of AIED-Lyso in acidic environments including lysosomes.
To evaluate the selectivity of AIED-Lyso, the F475/F620 ratio of AIED-Lyso solution was examined in the presence of HClO or other biologically relevant molecules including anions, reactive oxygen species (ROS) and thiols (Fig. 3A). Except for HClO, other biologically relevant molecules did not induce obvious variation in F475/F620. Moreover, a negligible interfering effect on the F475/F620 ratio of AIED-Lyso was found when HClO and other biologically relevant molecules were added together (Fig. 3B). All these results indicated that AIED-Lyso can selectively detect HClO in complex biological environments.
On the basis of the fluorescent response of SA-C2-PCD toward HClO, we anticipated that the strongly oxidized HClO can first oxidize the double bond between the SA-C2 moiety and pyrene moiety, then gradually hydrolyze into SA-C2-CHO and pyrene-CHO (Scheme S3, ESI†). The newly produced pyrene-CHO would form excimers in aqueous solution.27 Therefore, the change in the F475/F620 ratio can be linked to the response of SA-C2-PCD toward HClO, as shown in Fig. 2A. This proposed response mechanism was further confirmed by MS measurements. As expected, the mass peak at 730.4 m/z which corresponds to the nanoprobe SA-C2-PCD was replaced by mass peaks at 531.3 m/z and 231.1 m/z that correspond to SA-C2-CHO and pyrene-CHO, respectively (Fig. S12A and B, ESI†). These results supported the proposed reaction mechanism (Scheme S3, ESI†).
It has been well documented that small molecule-based probes with a morpholine moiety mainly accumulate in lysosomes;21,49 meanwhile, the intracellular uptake of nanoparticles is generally performed by the endocytosis strategy and they are often located in lysosomes.50–53 To increase the lysosomal targeting ability, we introduce morpholine groups onto the surface of the nanoparticles to sense HClO in lysosomes. To conduct the colocalization studies, HeLa cells were treated with both AIED-Lyso and LysoTracker Green (a commercial lysosomal tracker), and the results are given in Fig. 4. The red emission of AIED-Lyso fully overlapped with the green fluorescence of LysoTracker Green and the Pearson's R value was calculated to be 0.96 between our nanoprobe (shown in Red channel) and LysoTracker Green (shown in Green channel), which is far beyond the threshold of >0.5 required for correlation, indicating that AIED-Lyso mainly localized in lysosomes and can specifically monitor HClO in lysosomes.
AIED-Lyso was subsequently used for ratiometric imaging of exogenous HClO levels in HeLa cells. As shown in Fig. 5, HeLa cells treated with only AIED-Lyso provide strong red fluorescence and a low ratio of emission intensity (blue/red) (Fig. 5E, I and M). When the cells pre-treated with AIED-Lyso were exposed to different concentrations of HClO (10 μM, 20 μM and 30 μM), the blue fluorescence was obviously enhanced (Fig. 5J, K and L), accompanied by a decrease in red fluorescence (Fig. 5F, G and H). Accordingly, the ratio of emission intensity (blue/red) is also significantly enhanced (Fig. 5N, O and P). These results suggest that AIED-Lyso can be applied for ratiometric imaging of exogenous HClO in living cells. It was noted that the living cells were complicated systems, and the intracellular uptake of HClO was lower than the initial concentration. In addition, the intracellular reducing substances (e.g. GSH) can consume some of the HClO. Thus, a relatively high HClO concentration (10–30 μM) was applied to the cells in order to make the nanoprobe facile for ratiometric imaging of exogenous HClO levels in HeLa cells.
Finally, we imaged endogenous HClO in living cells. It has been well documented that endogenous HClO can be produced from RAW264.7 cells by treating them with lipopolysaccharide (LPS) and phorbol myristate acetate (PMA).54,55 As illustrated in Fig. 6, the RAW264.7 cells incubated with only AIED-Lyso showed bright red fluorescence with a low ratio of emission intensity (blue/red) (Fig. 6D, G and J). After stimulating with LPS and PMA, the RAW264.7 cells treated with AIED-Lyso revealed an obvious decrease in red fluorescence but a significant enhancement in blue fluorescence with a high ratio of emission intensity (blue/red) (Fig. 6E, H and K). To further confirm that the intracellular fluorescence emission changes were triggered by the endogenous HClO, N-acetylcysteine (NAC) was added as an effective ROS scavenger to reduce the cellular HClO level.56,57 As shown in Fig. 6F, I and L, when the RAW264.7 cells were incubated with LPS, PMA and NAC, the blue fluorescence was suppressed, whereas the red fluorescence was recovered to some extent. The above results demonstrated that AIED-Lyso can serve as a ratiometric nanoprobe to visualize the endogenously generated HClO in RAW264.7 cells.