A metering rotary nanopump for microfluidic systems
Abstract
We describe the design, fabrication, and testing of a microfabricated metering rotary nanopump for the purpose of driving fluid flow in microfluidic devices. The miniature peristaltic
Maintenance work is planned from 09:00 BST to 12:00 BST on Saturday 28th September 2024.
During this time the performance of our website may be affected - searches may run slowly, some pages may be temporarily unavailable, and you may be unable to access content. If this happens, please try refreshing your web browser or try waiting two to three minutes before trying again.
We apologise for any inconvenience this might cause and thank you for your patience.
* Corresponding authors
a
Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, VU Station B, Nashville, TN, USA
E-mail:
kevin.t.seale@vanderbilt.edu
Fax: +1 615 3224977
Tel: +1 615 3434124
b College of Medicine, Texas A&M University System Health Science Center, College Station, TX, USA
c Department of Physics, Sewanee: The University of the South, Sewanee, TN, USA
d Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
e Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, USA
f Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
g Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN, USA
We describe the design, fabrication, and testing of a microfabricated metering rotary nanopump for the purpose of driving fluid flow in microfluidic devices. The miniature peristaltic
S. G. Darby, M. R. Moore, T. A. Friedlander, D. K. Schaffer, R. S. Reiserer, J. P. Wikswo and K. T. Seale, Lab Chip, 2010, 10, 3218 DOI: 10.1039/C0LC00087F
To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.
If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.
If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.
Read more about how to correctly acknowledge RSC content.
Fetching data from CrossRef.
This may take some time to load.
Loading related content