Iron isotopic analysis of finger-prick and venous blood by multi-collector inductively coupled plasma-mass spectrometry after volumetric absorptive microsampling

Abstract

High-precision isotopic analysis of Fe in blood is currently assessed as a complementary approach to achieve a better understanding of human Fe metabolism and for diagnosis of diseases. Volumetric absorptive microsampling (VAMS) is a recently introduced technique that allows the straightforward collection of a well-defined volume of blood by dipping an absorbent polymeric tip into it. In this work, the use of VAMS was evaluated for high-precision isotopic analysis of whole blood Fe by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Fe concentrations in whole blood sampled using VAMS were determined by single-collector sector-field ICP-MS. A variety of solvents were evaluated for extraction of Fe from the VAMS-device (Mitra™). Fe was quantitatively extracted from the absorbent using 1 mL of Milli-Q water. The extracted material was subsequently subjected to acid digestion and to a miniaturized chromatographic procedure for isolation of Fe from the blood matrix. The Fe isotopic compositions and concentrations of paired finger-prick and venous blood samples collected at the same time from six individuals were compared. No significant differences were found between the two blood types. The proposed methodology significantly increases the sample throughput and facilitates sample acquisition for Fe isotopic analysis in clinical applications.

Graphical abstract: Iron isotopic analysis of finger-prick and venous blood by multi-collector inductively coupled plasma-mass spectrometry after volumetric absorptive microsampling

Supplementary files

Article information

Article type
Paper
Submitted
29 Okt 2016
Accepted
23 Dis 2016
First published
23 Dis 2016

J. Anal. At. Spectrom., 2017,32, 314-321

Iron isotopic analysis of finger-prick and venous blood by multi-collector inductively coupled plasma-mass spectrometry after volumetric absorptive microsampling

Y. Anoshkina, M. Costas-Rodríguez and F. Vanhaecke, J. Anal. At. Spectrom., 2017, 32, 314 DOI: 10.1039/C6JA00394J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements