Quantitative analysis of carbohydrate residues in Dextran 40 from various sources: A comparative study using high performance liquid chromatography coupled with charged aerosol detector

Abstract

Dextran 40, a typical high molecular weight carbohydrate drug refined through fermentation, is widely used in the clinical field in injectable form. The final product obtained through fermentation may contain by-products such as fructose and residual sucrose, which carry a risk of adverse reactions. Current quality standards do not effectively control for the possible presence of carbohydrate residues, and methods for detecting such residues are lacking. This gap in quality control is present in the vast majority of existing carbohydrate drugs. This study established and compared liquid chromatography methods equipped with three different detectors (RID, MS, CAD), selecting a convenient, rapid, and efficient HILIC-CAD method. This method combines the high sensitivity of HILIC-MS method with the high throughput of HILIC-RID method, using porous silica as the stationary phase and a highly-precision charged aerosol detector in tandem, achieving rapid separation and quantification of fructose and sucrose. Additionally, pre-treatment optimization was conducted to eliminate the impact of dextran 40 on the detection of fructose and sucrose. The method has been validated, showing good repeatability, recovery, robustness, and linearity, capable of quantifying carbohydrate residues at approximately 3.3 ppm. This study compared the residual levels of fructose and sucrose in dextran 40 obtained from different purification processes, analyzing key purification operations that influence the extent of carbohydrate residues. These findings provide a reference for optimizing the production process of dextran 40, ensuring the quality of the drug and public drug safety. Furthermore, the approach used in this study for detecting carbohydrate residues is applicable to the quality control of other carbohydrate drugs produced via fermentation.

Article information

Article type
Paper
Submitted
13 12月 2024
Accepted
19 1月 2025
First published
21 1月 2025
This article is Open Access
Creative Commons BY-NC license

Anal. Methods, 2025, Accepted Manuscript

Quantitative analysis of carbohydrate residues in Dextran 40 from various sources: A comparative study using high performance liquid chromatography coupled with charged aerosol detector

S. xie, Z. Jin, Y. Huang and Q. Huang, Anal. Methods, 2025, Accepted Manuscript , DOI: 10.1039/D4AY02242D

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements