Analytical method for total chromium and nickel in urine using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) in kinetic energy discrimination (KED) mode

Abstract

Biomonitoring and emergency response measurements are an important aspect of the Division of Laboratory Sciences of the National Center for Environmental Health, Centers for Disease Control and Prevention (CDC). The continuing advancement in instrumentation allows for enhancements to existing analytical methods. Prior to this work, chromium and nickel were analyzed on a sector field inductively coupled plasma-mass spectrometer (SF-ICP-MS). This type of instrumentation provides the necessary sensitivity, selectivity, accuracy, and precision but due to the higher complexity of instrumentation and operation, it is not preferred for routine high throughput biomonitoring needs. Instead a quadrupole based method has been developed on a PerkinElmer NexION™ 300D ICP-MS. The instrument is operated using 6.0 mL min−1 helium as the collision cell gas and in kinetic energy discrimination mode, interferences are successfully removed for the analysis of 52Cr (40Ar12C and 35Cl16O1H) and 60Ni (44Ca16O). The limits of detection are 0.162 μg L−1 Cr and 0.248 μg L−1 Ni. Method accuracy using NIST SRM 2668 level 1 (1.08 μg L−1 Cr and 2.31 μg L−1 Ni) and level 2 (27.7 μg L−1 Cr and 115 μg L−1 Ni) was within the 95% confidence intervals reported in the NIST certificate. Among-run precision is less than 10% RSDs (N = 20) for in house quality control and NIST SRM urine samples. While the limits of detection (LOD) for the new quadrupole ICP-UCT-MS with KED method are similar to the SF-ICP-MS method, better measurement precision is observed for the quadrupole method. The new method presented provides fast, accurate, and more precise results on a less complex and more robust ICP-MS platform.

Graphical abstract: Analytical method for total chromium and nickel in urine using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) in kinetic energy discrimination (KED) mode

Supplementary files

Article information

Article type
Paper
Submitted
31 八月 2013
Accepted
14 十月 2013
First published
22 十月 2013

J. Anal. At. Spectrom., 2014,29, 297-303

Analytical method for total chromium and nickel in urine using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) in kinetic energy discrimination (KED) mode

C. D. Quarles, D. R. Jones, J. M. Jarrett, G. Shakirova, Y. Pan, K. L. Caldwell and R. L. Jones, J. Anal. At. Spectrom., 2014, 29, 297 DOI: 10.1039/C3JA50272D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements