Towards low-cost bioanalytical tools for sarcosine assays for cancer diagnostics

Abstract

Sarcosine is an amino acid that has been listed as a new indicator for prostate cancer. We present here two low-cost tools with the potential to detect this biomarker excreted in urine. The first one is a paper-based microfluidic device manufactured by wax printing technology in which an enzymatic assay is performed. The enzymatic assay comprises two coupled enzymatic reactions between sarcosine oxidase and horseradish peroxidase, with the ABTS redox indicator oxidized when sarcosine is present in the sample. This enzymatic assay on paper could be used as a preliminary screening method and presents a linear range up to 1 mmol L−1, with a sensitivity of 21.2 A.U. (mmol L−1)−1; LOD = 0.21 mmol L−1; LOQ = 0.61 mmol L−1 and r2 = 0.8898. The second bioanalytical approach consists of a capillary electrophoresis method with capacitively coupled contactless conductivity detection (CE-C4D). This method proved to be useful to separate sarcosine from 12 amino acids typically found in normal human urine using 10 mmol L−1 of triethylamine (TEA) as the background electrolyte. This method could be used as a follow-up method after the initial screening and presented a stable baseline, LOD = 0.034 mmol L−1 and LOQ = 0.069 mmol L−1. Migration time reproducibility (RSD) for intraday and inter-day assays was smaller than 0.6% and 4.4%, respectively. Both tools were able to analyze this potential tumor marker for prostate cancer, with capabilities of miniaturization and low-cost, essential characteristics for point-of-care testing (POCT) technology. Paper-based devices are inexpensive and simple, making them ideal for screening tests and telemedicine, while separation by CE-C4D presents high sensitivity and throughput, useful characteristics for exploratory studies.

Graphical abstract: Towards low-cost bioanalytical tools for sarcosine assays for cancer diagnostics

Article information

Article type
Communication
Submitted
29 六月 2016
Accepted
13 九月 2016
First published
15 九月 2016

Anal. Methods, 2016,8, 7312-7318

Towards low-cost bioanalytical tools for sarcosine assays for cancer diagnostics

T. Mazzu-Nascimento, P. A. Gomes Carneiro Leão, J. R. Catai, G. G. Morbioli and E. Carrilho, Anal. Methods, 2016, 8, 7312 DOI: 10.1039/C6AY01848C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements