Issue 11, 2023

A single-stage anion exchange separation method for Cd isotopic analysis in geological and environmental samples by MC-ICP-MS

Abstract

AG-MP-1M anion exchange resin is commonly used to separate and purify Cd from geological and environmental samples. However, a second column using anion exchange, TRU Spec, or BPHA extraction resins is also required to further purify Cd from the residual Sn for high-precision Cd isotope ratio measurements. In this study, a new and efficient single-stage separation method using AG-MP-1M (100–200 mesh) anion exchange resin was developed to separate Cd from geological and environmental samples for high-precision Cd isotope ratio measurements. Most of the Sn (>99%) is effectively stripped from the resin using a 2 M HCl + 4 M HF mixed eluent, unlike commonly used separation protocols with AG-MP-1M anion exchange resin, which only removes ∼65% of the Sn using HCl eluent. Furthermore, potential residual Sn is retained on the resin by elution of 0.04 M HCl + 2 M HF and 0.005 M HCl + 2 M HF, which allows quantitative collection of the Cd fraction (∼99.5%) without Sn tailing. The single-stage purification procedure takes advantage of the different affinities of Sn on AG-MP-1M anion exchange resin at different HCl and HF concentrations in mixed HCl + HF solutions, which allows direct and effective separation of Cd from Sn and other complex sample matrices. We used this procedure and the double-spike MC-ICP-MS method to determine the δ114/110CdNIST SRM 3108 values for Mn nodule, igneous rock, shale, soil, and sediment reference materials, and obtained results that agree within analytical uncertainty with the values reported in previous studies. In addition, the δ114/110CdNIST SRM 3108 values of soil (GSS-1a), sediment (GSD-4a), and dolomite (GSR-12) standard reference materials are reported for the first time in this paper. The described purification procedure allows efficient and rapid Cd isotopic analysis in different types of geological and environmental samples.

Graphical abstract: A single-stage anion exchange separation method for Cd isotopic analysis in geological and environmental samples by MC-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
16 7月 2023
Accepted
19 9月 2023
First published
22 9月 2023

J. Anal. At. Spectrom., 2023,38, 2291-2301

A single-stage anion exchange separation method for Cd isotopic analysis in geological and environmental samples by MC-ICP-MS

Q. Zhong, L. Yin, J. Li, Y. Feng, N. Shen, B. Peng and Z. Wang, J. Anal. At. Spectrom., 2023, 38, 2291 DOI: 10.1039/D3JA00234A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements