Issue 3, 2023

Combined sewer overflows: relating event duration monitoring data to wastewater systems' capacity in England

Abstract

Water pollution caused by the frequent use of combined sewer overflows (CSOs) has been attracting increased media and political coverage in England as in other places in the world. Considering that each of the country's 14 346 CSOs has been assessed for their environmental risk potential, as defined by the Environment Agency, and they have each been permitted to act as a storm overflow is indicative of a more systemic problem than currently perceived. While looking at the duration and frequency of discharges from individual CSOs not much can be said about their causes nor about what needs to be done to reduce them, here through an extensive investigation of event duration monitoring (EDM) data for 2021 and 2020, CSO spills are shown to be an issue across all sewerage companies related to how they operate their systems. By analysing EDM data considering the type and location of CSOs, and the sewerage networks they are connected to, our findings reveal the chronic under capacity of the English wastewater systems as a fundamental cause behind the increased frequency and duration of CSO spills. Other than pumping stations, 82% of the CSOs with the maximum spill duration per system were located at storm tanks and inlets of treatment works and had on average significantly higher spill durations in systems with insufficient hydraulic capacity both in 2020 and 2021, suggesting that CSOs are used to protect the works under peak dry weather flow conditions. Such frequent, and in some cases independent of rainfall, use of CSOs, could have detrimental effects for the receiving environment, as well as put thousands of water users at risk.

Graphical abstract: Combined sewer overflows: relating event duration monitoring data to wastewater systems' capacity in England

Supplementary files

Article information

Article type
Paper
Submitted
17 8月 2022
Accepted
10 1月 2023
First published
13 1月 2023
This article is Open Access
Creative Commons BY license

Environ. Sci.: Water Res. Technol., 2023,9, 707-722

Combined sewer overflows: relating event duration monitoring data to wastewater systems' capacity in England

T. Giakoumis and N. Voulvoulis, Environ. Sci.: Water Res. Technol., 2023, 9, 707 DOI: 10.1039/D2EW00637E

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements