Issue 5, 2021

Ultrasensitive chemiluminescence immunoassay with enhanced precision for the detection of cTnI amplified by acridinium ester-loaded microspheres and internally calibrated by magnetic fluorescent nanoparticles

Abstract

A novel enhanced chemiluminescent immunoassay (CLIA) for ultrasensitive and excellent precisive determination of cardiac troponin I (cTnI) was reported. The method made full use of poly[(N-isopropyl acrylamide)-co-(methacrylic acid)] (P(NIPAM-co-MAA)) microspheres as new potential signal enhancers and magnetic fluorescent nanoparticles as internal standards for better precision. This protocol involved a sandwich format, in which the antigen in the sample was captured by the immobilized antibodies on the surface of magnetic fluorescent beads and recognized by the other antibodies labeled with acridinium ester (AE)-loaded P(NIPAM-co-MAA) microspheres. The combination of the remarkable sensitivity of the enhanced CLIA method and the use of P(NIPAM-co-MAA) microspheres as anti-cTnI carriers for acridinium ester signal amplification provided an extremely sensitive limit of blank (LoB) at 0.097 pg mL−1, a limit of detection (LoD) at 0.116 pg mL−1, and a limit of quantitation (LoQ) at 0.606 pg mL−1, much greater than those achieved by the classical chemiluminescence immunoassay (CLIA, Getein). Moreover, the intra-day variable coefficient can be improved to 1.21–2.12%, and inter-day variability was 2.01–3.49% under the application of magnetic fluorescent beads as an internal standard. The sensitivity and precision have reached a high level, comparable with the current commercial detection kits. The results showed a good correlation with a commercial chemiluminescence assay (CLIA, Abbott), with a correlation coefficient of 0.9883. This proposed method has been successfully applied to the clinical determination of cTnI in the human serum.

Graphical abstract: Ultrasensitive chemiluminescence immunoassay with enhanced precision for the detection of cTnI amplified by acridinium ester-loaded microspheres and internally calibrated by magnetic fluorescent nanoparticles

Article information

Article type
Paper
Submitted
09 11月 2020
Accepted
16 1月 2021
First published
19 1月 2021

Nanoscale, 2021,13, 3275-3284

Ultrasensitive chemiluminescence immunoassay with enhanced precision for the detection of cTnI amplified by acridinium ester-loaded microspheres and internally calibrated by magnetic fluorescent nanoparticles

H. Zhao, Q. Lin, L. Huang, Y. Zhai, Y. Liu, Y. Deng, E. Su and N. He, Nanoscale, 2021, 13, 3275 DOI: 10.1039/D0NR08008J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements