Issue 10, 2024

Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction

Abstract

In this work, a highly sensitive Nd isotopic analysis method by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) with ultrasound nebulization-dielectric barrier discharge (UNDBD) vapor generation as sample introduction is developed. The sensitivities of Nd isotopes determined by UNDBD are enhanced about 4.5 fold and 1.5 fold compared to conventional wet plasma and dry plasma, respectively, attributed to the generation of volatile Nd species during the dielectric barrier discharge (DBD) induced vapor generation process. Fractionation of Nd isotopes in UNDBD exhibits a mass-dependent characteristic, enabling successful correction of the 143Nd/144Nd ratio using the 146Nd/144Nd ratio with an exponential law. The minimum Nd concentration and volume required per analysis by UNDBD-MC-ICP-MS can be as low as 0.5 μg L−1 and 600 μL, thereby minimizing the sampling volume for Nd isotopic analysis in open seawater to 0.7 L. Interferences from residual major ions in seawater, present at mg L−1 level after pretreatment, are found to be negligible for Nd isotopic analysis by UNDBD-MC-ICP-MS. The long-term external precision (2RSD) for 143Nd/144Nd with 1 μg L−1 of Nd using this method is calculated as 64 ppm. The accuracy of 143Nd/144Nd determined by this method has been successfully validated by Nd isotopic standard solutions of GSB 04-3258-2015 and GBW04440. The Nd isotopic ratios determined in several seawater samples by UNDBD are in agreement with results obtained by the dry plasma method. UNDBD demonstrates both higher sensitivity and precision for Nd isotopic analysis compared to wet plasma and dry plasma sample introduction methods, making it more suitable for analyzing open seawater samples with low Nd concentrations and less sampling volume.

Graphical abstract: Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction

Supplementary files

Article information

Article type
Paper
Submitted
26 ⵎⴰⵕ 2024
Accepted
16 ⵢⵓⵍ 2024
First published
24 ⵢⵓⵍ 2024

J. Anal. At. Spectrom., 2024,39, 2395-2401

Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction

D. Li, G. Cui, S. Chen, Y. Qiao, Q. Liu, J. Zhang and Q. He, J. Anal. At. Spectrom., 2024, 39, 2395 DOI: 10.1039/D4JA00106K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements