Studying localized corrosion using liquid cell transmission electron microscopy†
Abstract
Localized corrosion of Cu and Al thin films exposed to aqueous NaCl solutions was studied using liquid cell transmission electron microscopy (LCTEM). We demonstrate that potentiostatic control can be used to initiate pitting and that local compositional changes, due to focused ion beam implantation of Au+ ions, can modify the corrosion susceptibility of Al films.
- This article is part of the themed collection: Structure and Catalyst Particles from In-situ Electron Microscopy