A biomarker-responsive nanoprobe for detecting hepatic ischemia-reperfusion injury via optoacoustic/NIR-II fluorescence imaging

Zhuo Zeng , Junjie Chen , Lihe Sun , Fang Zeng * and Shuizhu Wu *
State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China. E-mail: mcfzeng@scut.edu.cn; shzhwu@scut.edu.cn

Received 8th November 2022 , Accepted 12th December 2022

First published on 13th December 2022


Abstract

A nanoprobe for detecting hepatic ischemia-reperfusion injury has been developed. Apparent optoacoustic and NIR-II fluorescent signals are given out upon the nanoprobe's response to the in situ biomarker H2O2 in the liver in the case of ischemia-reperfusion injury.


Hepatic ischemia-reperfusion injury (HIRI) is a primary cause of liver damage and a common major complication in liver surgeries including liver transplantation/engraftment and hepatic resection.1,2 HIRI is typified by an inflammatory response and is the key cause for early or late liver dysfunction resulting in a high incidence of chronic or acute rejection as well as ultimate failure after liver transplantation, which further exacerbates the acute shortage of livers available for life-saving transplantation.2,3 HIRI is a multifactorial and complex pathophysiological process that is often involved in adverse clinical outcomes.4 Excessive production of reactive oxygen species (ROS) has been recognized as the critical factor in the genesis of HIRI and the crucial pathophysiological mechanism in HIRI.4,5 ROS, in particular H2O2 as the most stable and abundant ROS member, overproduced during reperfusion would directly cause tissue damage and set in motion a cascade of harmful reactions that lead to inflammation, cell death or even organ failure.4–6 Consequently, hepatic H2O2 can be employed as the in situ endogenous biomarker for HIRI. Once HIRI can be identified in the early phase, effective preventative or therapeutic strategies can be adopted to minimize the injury induced by ischemia and reperfusion processes during and/or after liver operations. Therefore, effective non-invasive detection/diagnostic approaches are essential for the avoidance of HIRI and thus saving lives.

Fluorescence noninvasive imaging in the second near-infrared (NIR-II, 900–1700 nm) window can facilitate imaging with greater penetration depth and enhanced sensitivity owing to the reduced photon scattering and low auto-fluorescence of tissues in this wavelength range.7–11 Meanwhile, optoacoustic imaging is a non-invasive hybrid imaging modality, which combines the advantages of optical imaging and ultrasound imaging while avoiding the limitations of pure optical imaging.12–14 Among optoacoustic imaging methods, multispectral optoacoustic tomography imaging (also known as MSOT imaging) is a functional optoacoustic imaging method; owing to the excitation by multiwavelength laser pulses and the probe-specific spectral unmixing, the reconstructed MSOT images can depict the spatiotemporal distribution of the specific probe or contrast agent in biological samples based on the spectral identification of the probe or contrast agent; consequently, the 3D MSOT images (e.g., orthogonal-view 3D images) would facilitate the accurate determination of the precise locality and size of the lesion or infection.15–20 Aided by biomarker-responsive probes, the integration of NIR-II fluorescence imaging and MSOT imaging would constitute an effective means for high-quality bioimaging which ensures that the obtained results are corroboratory.

Boron-dipyrromethene (BODIPY) dyes possess high quantum yield and easy structural modification,21 but the large planar conjugation of BODIPY-based NIR-II dyes causes such primary limitations as low water solubility/dispersibility, which hamper their biological applications in aqueous milieu. Hence, a water soluble or dispersible biomarker-responsive probe based on NIR-II BODIPY-type dyes together with NIR-II fluorescence imaging and MSOT imaging would synchronously offer biomarker-activatable detection and accurate delineation of the disease sites. In view of the above considerations, herein we designed a biomarker (H2O2)-responsive nanoprobe BX-BOH@BSA for the detection and imaging of HIRI via NIR-II fluorescence and MSOT imaging. The biofriendly and hydrophilic albumin (bovine serum albumin: BSA) serves as the matrix for encapsulating the molecular probe BX-BOH to form the nanoprobe BX-BOH@BSA, which ensures sufficient water dispersibility and good biocompatibility for biological applications. The fluorescence of the nanoprobe itself (BX-BOH@BSA ) is rather weak; whereas the presence of H2O2 leads to the evident enhancement of the fluorescent and optoacoustic signals due to the removal of the methylphenyl boronate group and the subsequent transformation of quaternized pyridyl into the uncharged pyridyl group (Scheme 1). The nanoprobe has been utilized in detecting and imaging HIRI in a mouse model through responding to the biomarker H2O2 in the hepatic region.


image file: d2cc06031k-s1.tif
Scheme 1 Illustrative scheme for the nanoprobe BX-BOH@BSA's formation and its detection of HIRI via responding to H2O2 in a mouse model with optoacoustic and NIR-II fluorescence imaging.

The molecular probe BX-BOH was prepared according to the synthesis process in Scheme S1 (ESI). And the related characterization data (NMR and HRMS spectra) are presented in Fig. S1–S6 (ESI). The molecular probe BX-BOH was obtained with 4-(bromomethyl)phenyl boronic acid being incorporated onto the NIR-II dye BX through the N-alkylation reaction of the pyridine group, by which the strong electron-pulling group quaternized pyridyl was formed. This quaternized pyridyl group (electron-pulling) plays a fluorescence-quenching role due to the photoinduced electron transfer effect,22 while the xanthene derivative is the electron-pushing moiety, and the methylphenyl boronate acts as a H2O2 responsive group. With BSA as the matrix to encapsulate the molecular probe BX-BOH molecules in PBS, the nanoprobe BX-BOH@BSA was prepared. The particle size distribution of the nanoprobe BX-BOH@BSA and the activated nanoprobe BX@BSA was assessed by the dynamic light scattering method, and from Fig. S7 (ESI) it is clear that the hydrodynamic size of the BX-BOH@BSA and BX@BSA nanoparticles is about 25[thin space (1/6-em)]nm and 20 nm.

The nanoprobe BX-BOH@BSA'S spectral response toward H2O2 was first investigated in PBS (containing 5% DMSO, pH 7.4). As presented in Fig. 1A and B, the H2O2-concentration-dependent fluorescence “turn-on” response (900–1300 nm with peak at 938 nm) can be clearly observed. The nanoprobe BX-BOH@BSA's time-dependent fluorescence spectra exhibit that the response reaches the maximal level in around 80 min (Fig. S8, ESI). In addition, the nanoprobe BX-BOH@BSA's optoacoustic intensity displays the H2O2-concentration-dependent enhancement (Fig. S9, ESI), as the nanoprobe's absorption in the 650–950 nm range increases significantly upon responding to H2O2 (Fig. S10, ESI). The limit of detection of the nanoprobe for H2O2 is determined as 0.77 μM (3σ/k). The extinction coefficient and fluorescence quantum yield of the nanoprobe after the response is 6.7 × 102 mL g−1 cm−1 and 0.46% (the reference standard: quantum yield 0.5% of 1,2-dichloroethane). The similarities of the fluorescence and absorption spectra between the probe compound BX-BOH and the nanoprobe BX-BOH@BSA, together with the zeta potentials of BX-OH and BX-BOH@BSA being slightly positive and negative (−27.9 mV), respectively, support that the molecular probe BX-BOH molecules were successfully encapsulated in the BSA matrix (Fig. S10, ESI). It is indubitable from these spectral data that BX-BOH@BSA can detect H2O2 with turn-on optoacoustic and NIR-II fluorescent signals.


image file: d2cc06031k-f1.tif
Fig. 1 (A) NIR-II fluorescence spectra for BX-BOH@BSA (0.6 mg mL−1) without and with incubation with H2O2 in PBS (with 5% DMSO, pH 7.4). (B) Fluorescence intensity at 938 nm for BX-BOH@BSA (0.6 mg mL−1) without or with incubation with H2O2 in PBS (with 5% DMSO, pH 7.4) (n = 3). (C) NIR-II fluorescence spectra of BX-BOH, BX-BOH@BSA and BX-BOH@BSA + H2O2 upon reaction with H2O2 (90 μM), respectively. (D) HPLC chromatograms for BX-BOH, BX, and BX-BOH were treated with H2O2 for 40 min (MeOH is the mobile phase with 1.0 mL min−1 flow rate).

To corroborate the molecular probe BX-BOH's response mechanism for H2O2, HPLC measurements were performed. As shown in Fig. 1D, the values of the retention time for the chromophore BX and the probe compound BX-BOH are 6.48 and 2.00 min, respectively. After incubation with H2O2, the peak of retention time for the probe compound BX-BOH decreases, while the retention time peak corresponding to BX appears, which substantiates that the reaction of the probe compound with H2O2 produces the chromophore BX. Afterwards, the response selectivity of the nanoprobe BX-BOH@BSA was tested with some biologically-related substances (Fig. S11, ESI); it is clear to be seen that the nanoprobe BX-BOH@BSA'S response toward H2O2 has relatively good selectivity. Based on density functional theory (DFT) calculation for BX-BOH and BX (Table S1, ESI), the energy gap supports the slightly blue-shifted change of absorption due to the transformation from BX-BOH to BX induced by H2O2.

Before applying the nanoprobe BX-BOH@BSA in animal experiments, we investigated the nanoprobe BX-BOH@BSA's biosafety. In this regard, firstly, we adopted the commonly-used MTT assay; as presented in Fig. S12 (ESI), BX-BOH@BSA's cytotoxicities toward mouse fibroblast cells (L929 cells) are quite low. Secondly, healthy mice were randomly assigned to two groups (5 mice per group) with one group receiving i.v. injection of the nanoprobe BX-BOH@BSA and the other group receiving saline for 7 days. The mice's body weights were monitored daily for 7 days after the injection (Fig. S13, ESI). It is clear that no obvious changes or differences exist in the mice's body weights for these 7 days. Furthermore, 7 days after injection of the nanoprobe or saline, the mice's main organs (heart, spleen, liver, kidney and lung) were collected upon the mice being euthanized and the histological analysis was conducted via H&E staining (Fig. S14, ESI). The histological data unambiguously exhibit that no discernible damage to these main organs of the mice exists after 7 days’ injection of the nanoprobe BX-BOH@BSA. These results support that the nanoprobe BX-BOH@BSA's biosafety is relatively good, which is appropriate for in vivo experimental applications.

Afterwards, the nanoprobe BX-BOH@BSA was applied in a mouse model to detect and monitor HIRI. For this purpose, the HIRI mouse model was established by following the previously-reported method.23 And the experimental protocol is shown in Fig. S22A (ESI). In this experiment, four groups of healthy mice were used. Among them, the mice of the first group underwent ischemia for the time period of 30[thin space (1/6-em)]min, which was followed by 24[thin space (1/6-em)]h reperfusion (notated as “I/R: 30 min/24 h”). The mice of the second group underwent ischemia for the time period of 60[thin space (1/6-em)]min, which was followed by 24[thin space (1/6-em)]h reperfusion (notated as “I/R: 60 min/24 h”). The mice of the third group underwent 0[thin space (1/6-em)]min ischemia (the sham group, notated as “Sham”). The mice of the fourth group (notated as “NAC”) underwent ischemia for the time period of 60[thin space (1/6-em)]min which was followed by 24 h reperfusion and then were treated with an antioxidative drug N-acetylcysteine (NAC) (150 mg kg −1 body weight daily starting from 2 d prior to the ischemia procedure) according to the reported treatment method.24

Subsequently, the different groups of mice were i.v. injected with BX-BOH@BSA (4.0 mg kg−1) and NIR-II fluorescent imaging was carried out. It is clearly seen from Fig. 2B and C that for the sham group, only rather weak fluorescence exists in the mice's liver region at 90 min after the nanoprobe BX-BOH@BSA's injection; contrarily, for the ischemia groups, the mice's liver region shows much more significantly evident fluorescent signals at the same time points. In addition, for the mice undergoing longer time of ischemia (ischemia for 60[thin space (1/6-em)]min), stronger fluorescent signals can be observed, owing to more hepatic H2O2 generated by longer ischemia time followed by reperfusion. Notably, as for the mice receiving treatment with NAC, there exist much weaker fluorescence signals in comparison to the groups without NAC treatment, because NAC scavenges much H2O2. In addition, for all the groups, the livers’ ex vivo NIR-II fluorescent imaging data clearly show evident fluorescent signals which enhances the lengthening ischemia time (Fig. 2D and Fig. S15, ESI).


image file: d2cc06031k-f2.tif
Fig. 2 (A) Illustration of the experimental process for the HIRI mouse model. (B) NIR-II fluorescent images of the sham group (0[thin space (1/6-em)]min ischemia) and the HIRI model groups (with 30[thin space (1/6-em)]min or 60[thin space (1/6-em)]min ischemia followed by 24[thin space (1/6-em)]h reperfusion) at 0, 30, or 90 min after BX-BOH@BSA's i.v. injection (4.0 mg kg−1). Mice were in supine posture. The liver region is shown by the green dotted line. (C) Average NIR-II fluorescent intensities of the liver region (ROI shown by green dotted line) corresponding to the mice of (B) (n = 5). (D) Bright-field images (on the left) and NIR-II fluorescent images (on the right) of the mice's livers at 90 min after BX-BOH@BSA's i.v. injection (4.0 mg kg−1).

Furthermore, the main organs (such as heart, spleen, liver, kidney and lung) were gathered from all the groups for MSOT imaging (Fig. S21, ESI). Obviously, the optoacoustic signals exist in the liver, and the mice's liver of the “I/R: 30 min/24 h” group or “I/R: 60 min/24 h” group exhibits much stronger optoacoustic signals compared to other organs.

Furthermore, the nanoprobe BX-BOH@BSA was employed in MSOT imaging for detecting HIRI in the mice. The scanning range for MSOT imaging is shown in Fig. S16 (ESI). From the orthogonal-view 3D images that were obtained from MSOT imaging recorded at varied time points after BX-BOH@BSA's injection (Fig. S17–S20, S22A and S22B, ESI), it is apparent that for the sham group mice, there exist rather weak optoacoustic signals in the hepatic region in comparison with the HIRI model groups. As for the model groups in which the mice underwent ischemia for various time periods, the optoacoustic signals in the liver region become much stronger as the ischemia time is lengthened. Meanwhile, for the NAC group in which the model mice were treated with NAC, a much abated optoacoustic signal exists in the liver. These MSOT imaging data corroborate the data from NIR-II fluorescent imaging experiments, and from these 3D MSOT images, HIRI's site and size can be observed more intuitively.

Moreover, the alanine transaminase (ALT) and aspartate aminotransferase (AST) levels in the mice's blood were measured by using ELISA kits, so as to evaluate the liver injury from the commonly-practiced perspective of the liver function evaluation.25 As shown in Fig. S22C and D (ESI), for the model groups (mice underwent ischemia for either 30 min or 60 min), the mice's ALT and AST levels in the blood are obviously higher than those for the sham group; this is indeed the case especially for the “I/R: 60 min/24 h” group, and the high blood ALT and AST levels confirm the liver injuries caused by the ischemia-reperfusion processes. Additionally, the liver tissues’ histological evaluation (by H&E staining) was performed as well for the mice; as displayed in Fig. S22E (ESI), the histological analysis data exhibit that the phenomena of hepatocyte vacuolation and necrosis are observable for the HIRI model mice with the extent becoming more severe for the mice undergoing longer ischemia time. In contrast, the sham group and the NAC group exhibit relatively normal morphology in the liver tissue sections.

In summary, we have developed a biomarker-responsive NIR-II fluorescent and optoacoustic nanoprobe BX-BOH@BSA for detecting and imaging HIRI. The probe compound can be activated by hepatic H2O2, thus generating evident optoacoustic and NIR-II fluorescent signals owing to the methylphenyl boronate group being removed and the subsequent transformation of the quaternized pyridyl into an uncharged pyridyl group. The nanoprobe BX-BOH@BSA may work as a utilizable tool for detecting HIRI, and the approach could provide useful ways of contriving other biomarker-responsive probes.

Z. Zeng: conceptualization, investigation and writing original draft. J. Chen and L. Sun: investigation. F. Zeng and S. Z. Wu: conceptualization, funding acquisition, project administration, supervision, writing reviewing and editing.

This work was supported by NSFC (22274057 and 21875069) and the Fund of Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates (2019B030301003).

Conflicts of interest

There are no conflicts to declare.

Notes and references

  1. Y. Zhai, H. Petrowsky, J. C. Hong, R. W. Busuttil and J. W. Kupiec-Weglinski, Nat. Rev. Gastroenterol. Hepatol., 2013, 10, 79–89 CrossRef CAS PubMed.
  2. B. L. Woolbright and H. Jaeschke, Hepatology, 2016, 63, 1427–1429 CrossRef PubMed.
  3. D. Xu, M. Xu, X. Kong and Q. Xia, J. Hepatol., 2018, 69, 746–758 CrossRef PubMed.
  4. S. P. Monga, Nat. Med., 2018, 24, 6–7 CrossRef CAS PubMed.
  5. M. Cannistrà, M. Ruggiero, A. Zullo, G. Gallelli, S. Serafini, M. Maria, A. Naso, R. Grande, R. Serra and B. Nardo, Int. J. Surg., 2016, 33, S57–S70 CrossRef.
  6. M. Peiseler and F. Tacke, Hepatology, 2021, 74, 2888–2890 CrossRef.
  7. Z. Qin, T. Ren, H. Zhou, X. Zhang, L. He, Z. Li, X. Zhang and L. Yuan, Angew. Chem., Int. Ed., 2022, 61, e202201541 CAS.
  8. S. Zhu, R. Tian, A. L. Antaris, X. Chen and H. Dai, Adv. Mater., 2019, 31, 1900321 CrossRef.
  9. L. Chen, J. Chen, Y. Fang, F. Zeng and S. Wu, Chem. Commun., 2021, 57, 7842–7845 RSC.
  10. J. Chen, L. Chen, Y. Wu, Y. Fang, F. Zeng, S. Wu and Y. Zhao, Nat. Commun., 2021, 12, 6870 CrossRef CAS.
  11. W. Cheng, H. Chen, C. Liu, C. Ji, G. Ma and M. Yin, View, 2020, 1, 20200055 CrossRef.
  12. Q. Fu, R. Zhu, J. Song, H. Yang and X. Chen, Adv. Mater., 2019, 31, 1805875 Search PubMed.
  13. Y. Liu, L. Teng, B. Yin, H. Meng, X. Yin, S. Huan, G. Song and X. Zhang, Chem. Rev., 2022, 122, 6850–6918 CrossRef CAS.
  14. Y. Wu, F. Zeng, Y. Zhao and S. Wu, Chem. Soc. Rev., 2021, 50, 7924–7940 RSC.
  15. J. Ouyang, L. Sun, F. Zeng and S. Wu, Coord. Chem. Rev., 2022, 458, 214438 CrossRef CAS.
  16. J. Ouyang, L. Sun, Z. Zeng, C. Zeng, F. Zeng and S. Wu, Angew. Chem., Int. Ed., 2020, 59, 10111–10121 CrossRef CAS.
  17. Z. Zhao, C. B. Swartchick and J. Chan, Chem. Soc. Rev., 2022, 51, 829–868 RSC.
  18. L. Wu, Y. Ishigaki, W. Zeng, T. Harimoto, B. Yin, Y. Chen, S. Liao, Y. Liu, Y. Sun, X. Zhang, Y. Liu, Y. Liang, P. Sun, T. Suzuki, G. Song, Q. Fan and D. Ye, Nat. Commun., 2021, 12, 6145 CrossRef CAS PubMed.
  19. S. Lei, J. Zhang, N. T. Blum, M. Li, D. Zhang, W. Yin, F. Zhao, J. Lin and P. Huang, Nat. Commun., 2022, 13, 1298 CrossRef CAS PubMed.
  20. L. A. Kasatkina, C. Ma, M. E. Matlashov, T. Vu, M. Li, A. A. Kaberniuk, J. Yao and V. V. Verkhusha, Nat. Commun., 2022, 13, 2813 CrossRef CAS.
  21. X. Chen, Y. Wu, X. Ge, L. Lei, L. Niu, Q. Yang and L. Zheng, Biosens. Bioelectron., 2022, 214, 114510 CrossRef CAS PubMed.
  22. X. Lv, T. Han, Y. Wu, B. Zhang and W. Guo, Chem. Commun., 2021, 57, 9744–9747 RSC.
  23. J. Liu, W. Zhang, C. Zhou, M. Li, X. Wang, W. Zhang, Z. Liu, L. Wu, T. D. James, P. Li and B. Tang, J. Am. Chem. Soc., 2022, 144, 13586–13599 CrossRef CAS.
  24. Y. Sun, L. Pu, L. Lu, X. Wang, F. Zhang and J. Rao, World J. Gastroenterol., 2014, 20, 15289–15298 CrossRef CAS PubMed.
  25. J. Nano, M. Ghanbari, W. Wang, P. S. Vries, K. Dhana, T. Muka, A. G. Uitterlinden, J. B. J. Meurs, A. Hofman, O. H. Franco, Q. Pan, S. D. Murad and A. Dehghan, Gastroenterology, 2017, 153, 1096–1106 CrossRef CAS.

Footnote

Electronic supplementary information (ESI) available: Experimental procedures, the probe's synthetic route, NMR/mass spectra, absorption/fluorescence spectra, cell viabilities, H&E staining images, NIR-II fluorescence images and MSOT images. See DOI: https://doi.org/10.1039/d2cc06031k

This journal is © The Royal Society of Chemistry 2023