Issue 45, 2015

Self-powered flexible pressure sensors with vertically well-aligned piezoelectric nanowire arrays for monitoring vital signs

Abstract

Human vital signs such as the heartbeat and respiration are important physiological parameters for public health care. Precisely monitoring these very minute and complex time-dependent signals in a simple, low-cost way is still a challenge. This study shows a novel fabrication of vertically well-aligned piezoelectric nanowire arrays with preferential polarization orientation as highly sensitive self-powered sensors for monitoring vital signs. The process realizes in situ poling of the P(VDF-TrFE) nanowires within the nanopores of the anodized aluminium oxide (AAO) template to yield a preferential alignment of both nanowires and the polymer chains required for superior sensitivity in one step. The resulting self-powered flexible sensor shows high sensitivity, good stability and strong power-generating performance. Under bending conditions, the device exhibits a maximum voltage of ∼4.8 V and a current density of ∼0.11 μA cm−2. The fabricated self-powered sensor shows a linear relationship of output voltage versus compressive force with a high sensitivity, and the piezoelectric voltage of the P(VDF-TrFE) nanowire array is enhanced 9 times that of conventional spin-coated bulk films. Furthermore, the highly sensitive vertically well-aligned nanowire array can be applied as a self-powered sensor for detecting some tiny human activities including breath, heartbeat pulse, and finger movements, which may possibly serve for medical diagnostics as sensors, robotics and smart electronic devices.

Graphical abstract: Self-powered flexible pressure sensors with vertically well-aligned piezoelectric nanowire arrays for monitoring vital signs

Supplementary files

Article information

Article type
Paper
Submitted
17 ⵢⵓⵍ 2015
Accepted
22 ⵛⵓⵜ 2015
First published
23 ⵛⵓⵜ 2015

J. Mater. Chem. C, 2015,3, 11806-11814

Author version available

Self-powered flexible pressure sensors with vertically well-aligned piezoelectric nanowire arrays for monitoring vital signs

X. Chen, J. Shao, N. An, X. Li, H. Tian, C. Xu and Y. Ding, J. Mater. Chem. C, 2015, 3, 11806 DOI: 10.1039/C5TC02173A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements