Issue 46, 2022

Covalent organic framework linked with amination luminol derivative as enhanced ECL luminophore for ultrasensitive analysis of cytochrome c

Abstract

Cytochrome c (cyt c) plays a critical role in mitochondrial respiratory chain, whose absence is detrimental to electron transport and reduce adenosine triphosphate. For ultrasensitive detection of cyt c, sheet-like covalent organic frameworks (COFs) were prepared by orderly accumulation of 1,3,5-benzenetricarboxaldehyde (BTA) and p-phenylenediamine (PDA), and further grafted with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) – an electrochemiluminescence (ECL) emitter. Specifically, the morphology and structure of the COFs-ABEI were mainly characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) analysis, and X-ray photoelectron spectroscopy (XPS). In parallel, the optical properties of the emitter were certified by UV-vis absorbance spectroscopy, Fourier infrared spectroscopy (FTIR), fluorescence (FL), and ECL measurements, showing 2.25-time enhanced ECL efficiency over pure ABEI, coupled by illustrating the interfacial electron transport mechanism. On the above foundation, a label-free “signal off” ECL biosensor was constructed by virtue of the specific immune recognition between the aptamer of the target cyt c with its capture DNA (cDNA) anchored on the biosensing platform, exhibiting a wider linear range of 1.00 fg mL−1–0.10 ng mL−1 (R2 = 0.998) and a lower limit of detection (LOD) down to 0.73 fg mL−1. This work offers some constructive guidelines for sensitive bioassays of disease-related biomarkers in the clinical field.

Graphical abstract: Covalent organic framework linked with amination luminol derivative as enhanced ECL luminophore for ultrasensitive analysis of cytochrome c

Supplementary files

Article information

Article type
Paper
Submitted
28 Лип 2022
Accepted
21 Жов 2022
First published
23 Лис 2022

Anal. Methods, 2022,14, 4767-4774

Covalent organic framework linked with amination luminol derivative as enhanced ECL luminophore for ultrasensitive analysis of cytochrome c

L. Shen, Y. Wang, H. Shan, J. Chen, A. Wang, W. Liu, P. Yuan and J. Feng, Anal. Methods, 2022, 14, 4767 DOI: 10.1039/D2AY01208A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements