Michael B.
Rooney‡
a,
Benjamin P.
MacLeod‡
ab,
Ryan
Oldford
a,
Zachary J.
Thompson
e,
Kolby L.
White
e,
Justin
Tungjunyatham
e,
Brian J.
Stankiewicz
e and
Curtis P.
Berlinguette
*abcd
aDepartment of Chemistry, The University of British Columbia, 2036 Main Mall, Vancouver, British Columbia, Canada V6T 1Z1. E-mail: cberling@chem.ubc.ca
bStewart Blusson Quantum Matter Institute, The University of British Columbia, 2355 East Mall, Vancouver, British Columbia, Canada V6T 1Z4
cDepartment of Chemical & Biological Engineering, The University of British Columbia, 2360 East Mall, Vancouver, British Columbia, Canada V6T 1Z3
dCanadian Institute for Advanced Research (CIFAR), MaRS Innovation Centre, 661 University Ave. Suite 505, Toronto, Ontario, Canada M5G 1M1
e3M Company, 3M Center, Maplewood, Minnesota 55144, USA
First published on 7th June 2022
We report a self-driving laboratory for adhesive material optimization. This autonomous laboratory combines a robot for preparing and testing adhesive bonds with a Bayesian optimizer to rapidly improve adhesive formulations. This system uses a single robot to perform a complex sequence of eight tasks including surface preparation, test specimen assembly, and bond strength evaluation. To enable automated strength testing, we developed an automated pull test method that correlates linearly with a single-lap-joint shear test method. This work demonstrates how flexible automation accelerates complex, multi-step experimental workflows for which commercial automation solutions are not available.
New adhesives are developed by iteratively preparing and testing experimental formulations. The overall adhesive development process is time-consuming because the number of possible formulations is large and multiple test specimens must be made and broken to characterize each formulation. One of the most common adhesive characterization methods is the single-lap-joint shear test (“lap shear” – e.g. ASTM D10026), where the test specimen consists of two rectangular coupons of material bonded together in an overlapping geometry (Fig. 1). The shear stress required to separate these coupons is a measure of the adhesive bond strength.6 The preparation of reliable and reproducible lap shear specimens requires a researcher to manually clean and abrade the coupons, deposit adhesive on them, close the joints, and fixture them in place for curing. The researcher must then wait hours to days for the specimens to cure before testing them. This testing is typically done by manually loading specimens into a universal tester one at a time. Although autosampling universal testers exist,7 they do not eliminate the time-consuming manual preparation of test specimens. This specimen preparation bottleneck limits the rate at which new formulations can be tested. The cognitive challenge of optimizing a multi-component formulation also slows the development of new adhesives. Here we describe a self-driving robotic laboratory which addresses both the rate of adhesive specimen testing and the challenge of choosing which formulations to test.
Our self-driving laboratory uses a robot to automatically create and test adhesive specimens. This robot employs a dolly pull-off test,8–10 which we show correlates with manual lap shear tests. The robot operator is only responsible for the initial stocking of consumables and dispensing the adhesive. Once set up, the laboratory can run without direct supervision and test up to 50 independent samples before restocking. Our robot significantly reduces the existing manual labor requirement of specimen creation and offers precise control over the time between forming and testing the bond.
We combined this robot with a Bayesian optimizer to enable the autonomous optimization of an adhesive formulation (Fig. 2). Bayesian optimizers iteratively search for input parameters that maximize an outcome and have previously been used to guide manual optimization of adhesive formulations.11 Autonomous workflows that combine optimizers with robotic experiments to optimize formulations are nascent12,13 and have not yet been reported for adhesives research. To demonstrate the capabilities of our self-driving laboratory, we used it to maximize the bond strength of a two-part epoxy by optimizing the resin to hardener ratio.
To prepare the robotic platform for operation, it was first manually stocked with dollies and test plates. The software was then configured to run the desired test. The workflow presented here used commercially available aluminum dollies with 10 mm or 20 mm diameter bond areas (Defelsko Corporation). Up to 50 dollies could be placed within reach of the robot on two dolly trays (25 dollies each). Test plates were waterjet cut from ¼ inch-thick 6061 aluminum sheets. Two alignment holes in each test plate facilitated accurate fixturing on the robotic platform. Other consumable items requiring periodic restocking included: a foam brush, isopropanol bath, abrasive pad, and abrasive tool.
The first step in the workflow was the automated cleaning of both the dollies and the test plates (Fig. 3c–f). The bottom face of each dolly was abraded by rapidly rotating the dolly (using the robot arm's gripper rotation) while in contact with an abrasive pad. The dolly was dipped in an isopropyl alcohol (IPA) bath to clean away the dust generated by the abrasion step and dried in a stream of compressed N2 gas. Digital photographs of the dolly's bottom face were taken at the camera station (BFS-U3-120S4C-CS, Teledyne FLIR LLC) before and after cleaning, and saved with all workflow data. The test plates were abraded by a medium coarse rotating abrasive disk tool which was held by the robot's rotating gripper and pressed downward onto the test plate. The distance between the gripper and test plate was manually adjusted until test plates were visibly cleaned of contaminants, and a consistent surface finish was observed. The robot arm did not have force feedback, however the downward force applied by the abrasive tool to the test plate was estimated to be 20 N. Accumulated dust and abrasion particulates were brushed clean with a disposable foam brush wetted with IPA. The foam brush was automatically cleaned by sonication in an IPA bath (PC3, L & R Manufacturing), then dried with a stream of N2 compressed gas. After cleaning both the dollies and the test plates, the robot assembled each specimen by picking up a dolly, dipping it in adhesive, and then placing it onto the test plate. Up to 25 specimens in a 5 × 5 pattern could be placed on each test plate. The adhesives to be tested are stored in trays adjacent to the test plates on the robotic platform. Each tray contained up to 5 adhesive formulations to test. Each formulation was stored in a disposable weigh boat and contained enough adhesive for up to 5 specimens. To set bond thickness, glass spacer beads (Envirospheres, E-SPHERES SL Grade SLG, mean particle size 0.130 mm) were manually mixed into the adhesive at 0.5% of the total adhesive mass. When the robot is ready to begin assembling specimens, the robot prompts the operator to manually dispense the adhesives to be tested into the weigh boats. For the two-part epoxies studied here (3M™ Scotch-Weld™ Epoxy Adhesive DP190 Gray and 3M™ Scotch-Weld™ Epoxy Adhesive DP420 Black), we experimentally determined that approximately 0.33 g of adhesive is needed per specimen. The robot arm dipped the dolly into the adhesive, performed pre-set movements to minimize dripping, and placed the dolly on the test plate. The robot placed each dolly on the test plate at a fixed height set to ensure the dolly firmly contacted the plate before being released by the gripper. The robotic system offers precise control over the time between bond formation and strength measurement. The bond strength measurements were performed one specimen at a time after a predetermined curing period.
The robot measured the adhesive bond strengths using a commercial pull-off adhesion tester (PosiTest ATA20, DeFelsko, Fig. 4b). This tester consists of a hydraulic actuator and a quick-release collar configured to pull a dolly away from a test plate with up to 7.55 kN of force. This tool was originally designed for manual use, so we modified it in order to automate its functions, and to enable it to be picked up by the robot (Fig. 4b and S2†). A 3D-printed chassis along with pneumatic pistons were added to the testing tool to actuate the internal collar. A longer metal handle was added to the tester tool to provide a cylindrical feature for the robot to grip. These modifications enabled fully automated docking, testing, and ejection of dollies. After locking on to a dolly, the test head increased the force at a rate of approximately 300 N s−1 until the bond failed. The normal force required to break the bond between the dolly and plate was recorded for each specimen. After performing the pull-off test, the robot captured an image of the adhesive failure surface on the dolly's bottom face. The robot then ejected the dolly into a discard bin, and reset the test head. This pull test took approximately 2 minutes, and was repeated for each dolly on the test plate.
Fig. 4 Robotic platform used to automatically create and test adhesive specimens. (a) The robot, stations, and tools used to execute the automated workflow (see also Fig. S1†). This system can create up to 50 test specimens from up to 10 unique formulations before the consumables (adhesives, dollies and test plates) need to be replenished. (b) Detailed view of the hydraulic strength testing tool used by the robot to measure bond strength. A variety of custom components added to the strength testing tool to enable automated operation are shown (see also Fig. S2†). (c) The sequence of operations performed by the system. After data is obtained by the robot, a Bayesian optimization algorithm is used to design the next batch of formulations to test. |
Fig. 5 Correlation between automated (pull-off) and manual (lap shear) adhesive strength tests. Bond strength data was obtained using triplicate pull-off tests executed by our robotic system, triplicate manual lap shear tests for 3M™ Scotch-Weld™ Epoxy Adhesive DP190 Gray, and referenced lap shear data for 3M™ Scotch-Weld™ Epoxy Adhesive DP420.17 Both adhesives were tested over a range of curing conditions (2–6 hours for 3M™ Scotch-Weld™ Epoxy Adhesive DP420, 1–5 days for 3M™ Scotch-Weld™ Epoxy Adhesive DP190 Gray) to assess the adhesive strength correlation over a wider range of values. Horizontal and vertical error bars indicate standard deviations of the recorded stresses across replicate samples. |
3M™ Scotch-Weld™ Epoxy Adhesive DP190 Gray is a flexible epoxy. Flexible epoxies provide an elastic bond that enables some movement between the adherends without failure. We compared pull-off tests for this epoxy to manual lap shear tests performed in our laboratory. These lap shear tests used 4 × 1 × 0.0625 inch aluminum coupons that were prepared by sandblasting followed by wiping with isopropanol before assembly with a 0.5 inch overlap using 0.003 inch diameter glass beads to control the bond thickness. The correlation slope between the tensile stress of the pull-off test and the shear stress of the lap shear tests was 2.29 over the range of cure conditions tested. 3M™ Scotch-Weld™ Epoxy Adhesive DP420 Black is a toughened epoxy. Toughened epoxies provide a more rigid but impact and fatigue-resistant bond. We compared pull-off tests for this epoxy to manual lap shear data from the material technical data sheet.17 The correlation slope was 0.72 (Fig. 5).
Correlations for both epoxy adhesives exhibited high degrees of linearity (R2 = 0.99 for 3M™ Scotch-Weld™ Epoxy Adhesive DP190 Gray; R2 = 0.99 for 3M™ Scotch-Weld™ Epoxy Adhesive DP420 Black). We attribute the differences in correlation slope to the very different mechanical properties of the two adhesives (flexible vs. toughened) and the different lap shear procedures employed (our manual preparation and testing of lap shear samples vs. datasheet reported values). These results show that the pull-off test is suitable for comparing the relative strengths of a given type of adhesive and can track rate-of-strength build as a function of cure time.
To demonstrate the capabilities of our self-driving laboratory, we used it to maximize the bond strength of an adhesive formulation. We performed this optimization by coupling our automated workflow to a Bayesian optimizer.15,16 Bayesian optimizers combine a surrogate model with an acquisition function. The surrogate model predicts the response of an experiment to the manipulated variables. The acquisition function determines which experiment(s) should be performed next to optimize the outcome of the experiment. The Bayesian optimization performed here manipulated the ratio of resin to hardener in a two-part epoxy system to maximize the strength as measured using the robotic pull-off test. We expressed this manipulated variable as a resin fraction R = massresin/(massresin + masshardner) to obtain a variable ranging from 0 to 1. The resin and hardener used in the formulation were taken from a commercially available two-part epoxy (3M™ Scotch-Weld™ Epoxy Adhesive DP420 Black).
We leveraged the ability of the robotic system to test multiple formulations in parallel by employing the AX Bayesian optimization package which supports batchwise acquisition of data from the experiment using the q-noisy expected improvement (qNEI) acquisition function.18,19 Once a batch of formulations was requested by this optimizer, formulations with the requested resin fraction were prepared by manually weighing individual components into a weigh boat on a digital weigh scale. The formulations were then mixed by hand with a stir stick before being loaded onto the robotic platform. This step was followed by completely automated specimen preparation, curing for 3 h, and testing. The resulting data is used to update the optimizer's surrogate model and a new batch of formulations is requested, beginning the next round of the optimization.
Each round of the optimization involved testing a batch of five formulations in triplicate (Fig. 6 and Tables S4–S7†). The resin fractions for the five formulations tested in the first round were selected using a scrambled sobol sequence. The resulting data was used to initialize the Gaussian process surrogate model used by the optimizer. The sobol sequence and surrogate function used the default settings implemented in the AX Bayesian optimization package.18 The resin fractions for subsequent rounds were selected by the optimizer using the qNEI acquisition function. Dolly images acquired after the pull-off tests showed wet-looking residual material consistent with incompletely cured adhesive for resin ratios below 0.2 or above 0.7. The images of dollies with resin ratios between 0.2 and 0.7 showed dry-looking residual material consistent with cured adhesive. The region containing the optimal resin fraction to maximize strength was very clearly defined after four rounds of optimization. In the particular experimental optimization campaign shown here, the formulation with the highest strength was identified in round 1 by random chance. Simulated optimization campaigns using the same optimizer configuration as the real-world experiments showed that when the optimum formulation is not identified in round 1, the optimizer will converge on the optimal formulation in subsequent rounds (see Fig. S4†). These results demonstrate that our self-driving laboratory can find an optimal resin fraction for maximizing the tensile strength of a 2-part epoxy. This self-driving lab could be adapted to the optimization of more complex formulations.
For example, increased ambient lab temperatures in optimization round 4 increased the curing rate, resulting in increased strength at the same epoxy fraction (compare Fig. 4c with Fig. 4d). A temperature-controlled curing environment would mitigate this problem. We note that the samples in this study were cured for less time than specified in the technical datasheet.
Consistent surface preparation is critical to obtaining repeatable bond strength data. While we manually changed the abrasion tools and pads employed in our setup at regular intervals to maintain consistent surface preparation, a more advanced system might automatically use fresh abrasion media on a schedule. Alternatively, fresh adhesive media could be adaptively requested by the system in response to feedback from automated surface quality assurance measurements.
In this study, we manually developed a dip and place routine that minimized unwanted dripping of adhesives. To facilitate working with new adhesives having different fluid characteristics, automatic optimization of the dip and place routine using feedback (e.g., from a weigh scale or machine vision) would be beneficial.
Our robotic system automatically photographs the bottom surface of every dolly after testing. These images could be automatically processed with machine vision to help classify the bond failure mode or categorize morphological defects.20 This information could be used to alert the researcher if an outlier occurred.
While we presented a single-parameter, single-objective optimization here, this optimization could be extended to incorporate multiple manipulated variables or multiple optimization objectives. Such extensions would be synergistic with hardware upgrades.12,16 For example, incorporating an oven into the robot would enable the optimization of thermal curing protocols. Expert knowledge (such as the range of resin ratios likely to yield high strength) or bond strength estimates based on simulations21 could also be incorporated to increase the efficiency of the Bayesian optimization.22,23
This work shows how flexible automation can enable materials scientists to automate complex, multi-step experimental workflows for which commercial automation solutions are not available.24 Self-driving laboratories will empower human experts to rapidly develop high performance adhesives and other complex formulated materials.