Issue 8, 2020

Multiplexed detection of biomarkers in lateral-flow immunoassays

Abstract

Multiplexed detection of biomarkers, i.e., simultaneous detection of multiple biomarkers in a single assay, is a process of great advantages including enhanced diagnostic precision, improved diagnostic efficiency, reduced diagnostic cost, and alleviated pain of patients. A typical lateral-flow immunoassay (LFIA) is a widely used paper-based immunochromatographic test strip designed to detect a target biomarker through two common formats: sandwich assay and competitive assay. In order to obtain qualitative or quantitative results, a probe with unique optical or magnetic properties is usually employed to characterize the concentration of the target biomarker. The typical LFIA is suitable for point-of-care testing due to its simplicity, portability, cost-effectiveness, and rapid detection of a target biomarker. However, detection of a single biomarker in the typical LFIA is not favorable for high throughput analysis. Therefore, multiplexed detection of biomarkers in LFIAs has been extensively studied in recent years for high throughput analysis. To accomplish multiplexed detection of biomarkers in LFIAs, the most frequently used structure is a test strip with multiple test lines (TLs), where each TL can detect a specific biomarker. An alternative structure, i.e., a multi-channel structure with multiple test strips, where each test strip has one TL for detecting a specific biomarker, is employed for multiplexed detection of biomarkers. Sometimes, a single test strip with only one TL containing different receptors, where each detection receptor corresponds to a specific biomarker, is another structure applied for multiplexed detection of biomarkers. This paper reviews three common structures for multiplexed detection of biomarkers in LFIAs, i.e., a test strip with multiple TLs, a multi-channel structure with multiple test strips, and a test strip with a single TL. Based on the three common structures, different signal detection strategies that include colorimetric detection, fluorescence detection, surface-enhanced Raman scattering detection, and magnetic detection, along with performance and perspectives are discussed.

Graphical abstract: Multiplexed detection of biomarkers in lateral-flow immunoassays

Article information

Article type
Minireview
Submitted
09 Ara 2019
Accepted
02 Mar 2020
First published
03 Mar 2020

Analyst, 2020,145, 2828-2840

Multiplexed detection of biomarkers in lateral-flow immunoassays

L. Huang, S. Tian, W. Zhao, K. Liu, X. Ma and J. Guo, Analyst, 2020, 145, 2828 DOI: 10.1039/C9AN02485A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements