Issue 8, 2011

Mass spectrometric imaging of elements in biological tissues by new BrainMet technique—laser microdissectioninductively coupled plasma mass spectrometry (LMD-ICP-MS)

Abstract

Bioimaging of elements in biological tissues is a fast growing technology in the life sciences since it provides direct information on the metal distribution which is involved in metabolism in all kinds of organisms. In the present study, we proposed a novel mass spectrometric imaging technique, laser microdissection inductively coupled plasma mass spectrometry (LMD-ICP-MS), which is intended to investigate elemental distribution in small areas of biological tissue with high spatial resolution down to the low-micrometre range and below. The LMD-ICP-MS technique combines a laser microdissection apparatus (LMD) with sensitive quadrupole-based inductively coupled plasma mass spectrometry (ICP-QMS) to utilize the tightly focused laser beam in LMD for the ablation of sample materials which then are analyzed by ICP-QMS. The laser beam with a 1 μm spot diameter was used to ablate the material from a Cu-spiked brain tissue slice, and corresponding ion intensities of elements of interest (for instance, 13C+ and 63Cu+) were observed by ICP-QMS along the scan. First images of metals and selected non-metals were obtained using the new LMD-ICP-MS imaging technique on small regions of the brain standard slice. Inhomogeneous distribution of the materials (via the image of 13C+) and elements (via the images of 23Na+, 24Mg+, 31P+, 56Fe+, 63Cu+, 64Zn+) in the scanned regions was revealed by LMD-ICP-MS imaging with a spatial resolution of 30 μm, 15 μm, and 8 μm, respectively. Additionally, images of P, Mg, K and Fe with a lateral resolution of 4 μm in a region of a mouse brain slice were obtained by imaging LMD-ICP-MS. Quantification in LMD-ICP-MS was possible via calibration curves generated by a set of synthetic brain standards similar to the procedure in laser ablation ICP-MS. Further studies with respect to the performance of LMD-ICP-MS and the optimization of experimental parameters when using laser beams with smaller spot sizes in LMD will be carried out in developing the LMD-ICP-MS imaging technique.

Graphical abstract: Mass spectrometric imaging of elements in biological tissues by new BrainMet technique—laser microdissection inductively coupled plasma mass spectrometry (LMD-ICP-MS)

Article information

Article type
Paper
Submitted
21 มี.ค. 2554
Accepted
06 ก.ค. 2554
First published
12 ก.ค. 2554

J. Anal. At. Spectrom., 2011,26, 1653-1659

Mass spectrometric imaging of elements in biological tissues by new BrainMet technique—laser microdissection inductively coupled plasma mass spectrometry (LMD-ICP-MS)

B. Wu, S. Niehren and J. S. Becker, J. Anal. At. Spectrom., 2011, 26, 1653 DOI: 10.1039/C1JA10106D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements