Isotope ratio mapping by means of laser ablation-single collector-ICP-mass spectrometry: Zn tracer studies in thin sections of Daphnia magna

Abstract

In this paper, the possibilities of LA-single collector-ICP-mass spectrometry for obtaining isotope ratio images of thin sections of Daphnia magna specimens exposed to isotopically enriched Zn tracers were evaluated. Zn was selected considering its importance in ecotoxicological studies. All aspects of the analytical methodology deployed were carefully studied and optimized for obtaining the best isotope ratio precision and accuracy. The development of this methodological approach consisted of: (i) evaluation of the performance of two different medium mass resolution exit slits, a conventional one providing a mass resolution of mm ≈ 4000 and triangular shaped peaks, and another (wider) one, offering a lower mass resolution (mm ≈ 2000), but providing enhanced ion transmission and flat-topped peaks; (ii) the use of a wet plasma for improving plasma robustness; (iii) thorough optimization of the ablation conditions (such as laser spot size, repetition rate, scan speed and laser fluence) and data acquisition parameters (such as scan mode, the number of nuclides monitored, mass window, the number of samples per peak and dwell times); and (iv) adequate data treatment including the use of the moving average of 5 individual values. With the methodology developed, isotope ratio images with 30 micrometer spatial resolution scale were obtained for exposed and unexposed Daphnia magna individuals. The typical overall uncertainty of the measurements was approximately 5% RSD for the 66Zn/64Zn and 68Zn/64Zn ratios, which can be considered as satisfactory taking into account that the amount of Zn present per 30 μm × 30 μm pixel only reached a few picograms in the most favourable cases (giving rise to 10 000–20 000 counts per s for 64Zn). These results open the possibility for tracer studies with stable isotopes to be carried out using single collector instrumentation, a much more widespread analytical technique than multi-collector ICP-MS.

Graphical abstract: Isotope ratio mapping by means of laser ablation-single collector-ICP-mass spectrometry: Zn tracer studies in thin sections of Daphnia magna

Article information

Article type
Paper
Submitted
14 Mac 2013
Accepted
01 Mei 2013
First published
02 Mei 2013

J. Anal. At. Spectrom., 2013,28, 1005-1015

Isotope ratio mapping by means of laser ablation-single collector-ICP-mass spectrometry: Zn tracer studies in thin sections of Daphnia magna

M. R. Flórez, M. Aramendía, M. Resano, A. C. Lapeña, L. Balcaen and F. Vanhaecke, J. Anal. At. Spectrom., 2013, 28, 1005 DOI: 10.1039/C3JA50087J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements