Rapid determination of chemical losses in a microplate bioassay using fluorescence spectroscopy

Abstract

The increase in production and innovation of chemicals that humans interface with has enhanced the need for rapid toxicity testing of new and existing chemicals. This need, along with efforts to reduce animal testing, has led to the development of high-throughput bioassays typically conducted in microplates. These bioassays offer time and resource advantages over traditional animal models; however, significant chemical losses can occur in microplates. Current methods for measuring chemical losses in microplates require extensive sample preparation and highly sensitive instruments. We propose the use of fluorescence spectroscopy to measure chemical losses in high-throughput bioassays as a low resource alternative to the existing methods. A fluorescent plate reader was used to develop methods for quantifying the aqueous concentrations of two chemicals, 2-hydroxynaphthalene and acridine, in microwells of a 96-well microplate. A high-throughput, 5 day embryonic zebrafish bioassay was used as the model bioassay for method development. Chemical losses were attributed to a combination of photodegradation, sorption, and uptake by the zebrafish embryos, kinetics of which were derived from a pseudo-first order model. Chemical uptake amount was calculated to be approximately 50% and 21% of the total chemical amount added for 2-hydroxynaphthalene and acridine, respectively. Unexpected cranial deformities were observed in the embryonic zebrafish, suggesting further investigation of potential additive toxicity of the ultraviolet radiation exposure from fluorescence measurements and chemical exposure is needed. Nonetheless, this novel method provides a rapid, low resource approach to measuring chemical losses in microplates that can be extended to a variety of autofluorescent chemicals and microplate-based bioassays.

Graphical abstract: Rapid determination of chemical losses in a microplate bioassay using fluorescence spectroscopy

Supplementary files

Article information

Article type
Paper
Submitted
30 okt 2024
Accepted
03 dec 2024
First published
10 dec 2024

Anal. Methods, 2025,17, 514-524

Rapid determination of chemical losses in a microplate bioassay using fluorescence spectroscopy

J. M. Huizenga, L. Truong and L. Semprini, Anal. Methods, 2025, 17, 514 DOI: 10.1039/D4AY01980F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements