Issue 8, 2013

Forensic analysis of glass by μ-XRF, SN-ICP-MS, LA-ICP-MS and LA-ICP-OES: evaluation of the performance of different criteria for comparing elemental composition

Abstract

Four interlaboratory tests were designed to evaluate the performance of match criteria for forensic comparisons of elemental composition of glass by μ-XRF, solution nebulization SN-ICP-MS, LA-ICP-OES and LA-ICP-MS. A total of 24 analysts in 18 laboratories participated in the tests. Glass specimens were selected to study the capabilities of the techniques to discriminate glass produced in the same manufacturing plant at different time intervals and to associate samples that originated from a single source. The assessment of the effectiveness of several match criteria included: confidence interval (±6s, ±5s, ±4s, ±3s, ±2s), modified confidence interval, t-test, range overlap, and Hotelling's T2. Error rates are reported for each of these criteria. Recommended match criteria were those found to produce the lowest combinations of type 1 and type 2 error rates. Performance of the studied match criteria was dependent on the homogeneity of the glass sources, the repeatability between analytical measurements, and the number of elements that were measured. The best results for μ-XRF data were obtained using spectral overlay followed by a ±3s confidence interval or range overlap. For ICP-based measurements, a wider match criterion, such as a modified confidence interval based on a fixed minimum relative standard deviation (±4s, >3–5% RSD), is recommended due to the inherent precision of those methods (typically <1–5% RSD) and the greater number of elements measured. Glass samples that were manufactured in different plants, or at the same plant weeks or months apart, were readily differentiated by elemental composition when analyzed by these sensitive methods.

Graphical abstract: Forensic analysis of glass by μ-XRF, SN-ICP-MS, LA-ICP-MS and LA-ICP-OES: evaluation of the performance of different criteria for comparing elemental composition

Article information

Article type
Paper
Submitted
06 apr 2013
Accepted
10 jún 2013
First published
11 jún 2013

J. Anal. At. Spectrom., 2013,28, 1270-1282

Forensic analysis of glass by μ-XRF, SN-ICP-MS, LA-ICP-MS and LA-ICP-OES: evaluation of the performance of different criteria for comparing elemental composition

T. Trejos, R. Koons, P. Weis, S. Becker, T. Berman, C. Dalpe, M. Duecking, J. Buscaglia, T. Eckert-Lumsdon, T. Ernst, C. Hanlon, A. Heydon, K. Mooney, R. Nelson, K. Olsson, E. Schenk, C. Palenik, E. C. Pollock, D. Rudell, S. Ryland, A. Tarifa, M. Valadez, A. van Es, V. Zdanowicz and J. Almirall, J. Anal. At. Spectrom., 2013, 28, 1270 DOI: 10.1039/C3JA50128K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements