Issue 13, 2023

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Abstract

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

Graphical abstract: Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Supplementary files

Article information

Article type
Paper
Submitted
01 mar 2023
Accepted
26 máj 2023
First published
30 máj 2023

Lab Chip, 2023,23, 3016-3033

Author version available

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

D. Doppler, M. Sonker, A. Egatz-Gomez, A. Grieco, S. Zaare, R. Jernigan, J. D. Meza-Aguilar, M. T. Rabbani, A. Manna, R. C. Alvarez, K. Karpos, J. Cruz Villarreal, G. Nelson, J. Yang, J. Carrion, K. Morin, G. K. Ketawala, A. L. Pey, M. A. Ruiz-Fresneda, J. L. Pacheco-Garcia, J. A. Hermoso, R. Nazari, R. Sierra, M. S. Hunter, A. Batyuk, C. J. Kupitz, R. E. Sublett, S. Lisova, V. Mariani, S. Boutet, R. Fromme, T. D. Grant, S. Botha, P. Fromme, R. A. Kirian, J. M. Martin-Garcia and A. Ros, Lab Chip, 2023, 23, 3016 DOI: 10.1039/D3LC00176H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements