Issue 9, 2022

Analytical feasibility of a new reference material (IRMM-524A Fe metal) for the in situ Fe isotopic analysis of pyrite and ilmenite without matrix effects by femtosecond LA-MC-ICP-MS

Abstract

Nowadays, in situ Fe isotopic analysis is facing a dilemma that the conventional reference material of IRMM-014 for isotope ratio normalization is commercially unavailable and is unable to meet the needs of laboratories. In this study, the other Fe metal (IRMM-524A), instead of the nearly exhausted IRMM-014, has been systematically checked to be a potential reference material for the Fe isotopic analysis by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry (fs LA-MC-ICP-MS). A total of 136 analyses on IRMM-524A were directly calibrated against IRMM-014 using fs LA-MC-ICP-MS during eight analytical sessions. The result shows that the IRMM-524A Fe metal is relatively homogeneous, with average values of 0.01 ± 0.13‰ and −0.02 ± 0.19‰ (2SD, n = 136) for δ56Fe and δ57Fe, respectively, which are identical to the published values obtained by solution nebulizer (SN)-MC-ICP-MS within analytical uncertainties. Fe isotopic compositions of two in-house standards (Balmat pyrite, PZH12-24 ilmenite) and four natural samples (NKAu01 pyrite, PZH12-16 ilmenite, PZH12-18 ilmenite, and Moosilauke ilmenite) measured by fs LA-MC-ICP-MS relative to IRMM-524A or IRMM-014 are identical within analytical uncertainties. In addition, five of the samples (Balmat pyrite, PZH12-24 ilmenite, NKAu01 pyrite, PZH12-16 ilmenite, and PZH12-18 ilmenite) have homogeneous Fe isotopic compositions and yield an external reproducibility of 0.12‰ to 0.16‰ for δ56Fe values for different sections within three years. Thus, the IRMM-524A Fe metal and other five samples can be used as reference material and secondary standards for quality assurance for non-matrix-matched Fe isotopic analysis of pyrite and ilmenite by fs LA-MC-ICP-MS.

Graphical abstract: Analytical feasibility of a new reference material (IRMM-524A Fe metal) for the in situ Fe isotopic analysis of pyrite and ilmenite without matrix effects by femtosecond LA-MC-ICP-MS

Article information

Article type
Paper
Submitted
05 máj 2022
Accepted
29 jún 2022
First published
30 jún 2022

J. Anal. At. Spectrom., 2022,37, 1835-1845

Analytical feasibility of a new reference material (IRMM-524A Fe metal) for the in situ Fe isotopic analysis of pyrite and ilmenite without matrix effects by femtosecond LA-MC-ICP-MS

L. Xu, J. Yang, H. Wang, L. Xie, Y. Yang, C. Huang and S. Wu, J. Anal. At. Spectrom., 2022, 37, 1835 DOI: 10.1039/D2JA00151A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements