Issue 20, 2015

A two-phase approach to fourier transform ion mobility time-of-flight mass spectrometry

Abstract

It is well known that the duty cycle of common drift-tube ion mobility experiments is often below 1%. However, multiplexing approaches such as Fourier and Hadamard pulsing schemes have been shown to independently enhance the throughput of ion mobility spectrometry (IMS) experiments to levels that approach 50%. While challenges remain to their broad scale implementation we describe a new Fourier transform (FT) IMS experiment that is directly compatible with standard drift tube ion mobility mass spectrometers (DT-IMMS). Compared to previous FT-IMS experiments, our new approach requires only a single gate and circumvents the need for signal apodization by combining data from two frequency pulsing sequences 180° out of phase. Assessment of our initial results highlights an increase in signal-to-noise (SNR) relative to both previous implementations FT-IMS experiments and signal averaged (SA) experiments. For select tetraalkylammonium salts SNR improvements of more than one order of magnitude are routinely possible. To explore the performance metrics associated with the technique a number of experimental variables were systematically altered including frequency sweep range, sweep time, and data acquisition time. Using this experimental design we present the key aspects, considerations, and minimum resources necessary for other IMS researchers to incorporate this operational mode into their research. The two-phase FT-IMMS technique offers a tractable mechanism to enhance sensitivity for IMMS measurements and its broad-scale adoption by IMMS researchers promises to enhance the acquisition speed for mobility measurements using hybrid instrumentation.

Graphical abstract: A two-phase approach to fourier transform ion mobility time-of-flight mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
11 máj 2015
Accepted
05 aug 2015
First published
06 aug 2015

Analyst, 2015,140, 6862-6870

Author version available

A two-phase approach to fourier transform ion mobility time-of-flight mass spectrometry

B. H. Clowers, W. F. Siems, Z. Yu and A. L. Davis, Analyst, 2015, 140, 6862 DOI: 10.1039/C5AN00941C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements