This review covers developments in ‘Atomic Spectrometry’. It covers atomic emission, absorption, fluorescence and mass spectrometry, but excludes material on speciation and coupled techniques which is included in a separate review. It should be read in conjunction with the previous review1 and the other related reviews in the series.2–6 A critical approach to the selection of material has been adopted, with only novel developments in instrumentation, techniques and methodology being included. One of the major developments which has gained traction over the past few years is the use of elemental tagging for the relative and absolute quantification of biological molecules using ICP-MS. This has advanced to the stage where it is now routinely used as an assay technique. A number of variations on this approach have also been developed in order to improve sensitivity by amplification of the signal, particularly for polynucleotide analysis. Single particle analysis by ICP-MS and ICP-AES has been used to gain some valuable insights into the atomisation and ionisation processes occurring in the ICP, as well as providing a means of quantification of nanoparticles. The dielectric barrier discharge (DBD) has attracted interest as a compact, low-power, microplasma source for MS and AES, following the trend for all things miniature, as well as for direct analysis of liquids. The use of MC-ICP-MS is the driver behind advances in the isotope ratio analysis of natural stable isotopes of metallic elements. Double spiking is an expanding method to neutralise instrumental and procedural mass-dependent fractionation in both stable and radiogenic isotope systems. An overlap is emerging between the measurement of uranium isotope variation in natural systems and the U isotope determination for the nuclear forensic or monitoring/safeguarding fields. Coincident analytical techniques between these fields is likely to produce useful advances in the analysis of nuclear materials.
Building on their previous work, Su et al.9 have incorporated non-functionalised PVC tubing as the SPE medium for online analysis of living rat brain microdialysates using ICP-MS. The lab-on-a-valve (LOV) system was designed to operate by taking segmented flow samples of microdialysate and adjusting the pH by 1 + 3 dilution with 40 mM phosphate buffer to optimise absorption of metal ions onto orange/green PVC peristaltic tubing (48 cm long × 0.38 mm i.d.). Elution was achieved with 0.2% nitric acid. The flow-rate was only 20 μL min−1 so a micro-flow nebuliser was necessary for ICP-MS detection. In this way, using segmented flow preconcentration, temporal changes in Co, Cu, Mn, Ni and Zn concentration could be measured in vivo at sub μg L−1 levels. This reviewer must confess to being somewhat surprised by the efficacy of PVC tubing as an SPE medium, however, the authors obtained spike recoveries of between 88 and 107%. In a second paper10 the same authors adopted a similar approach, but using a minicolumn packed with PVC beads instead of bare tubing. They used the system to monitor the permeability of the blood–brain barrier to MMA, DMA, molybdate and MeHg.
Magnetic nanoparticles (MNPs) have been widely used as substrates for SPE due to the ease with which they can be used to separate the analyte from the matrix after preconcentration. The field was reviewed (88 references) by Wierucka and Biziuk11 who outlined the process and tabulated applications with respect to analyte, MNP coating, technique, LOD etc. A variety of substances have been used to coat MNPs (e.g. silica, alumina, manganese oxide graphene, divinylbenzene, polyamidoamines, surfactants and IPs). In this vein, Najafi et al.12 coated an MNP with an IIP to act as an SPE substrate for the determination of Hg. The Fe3O4 MNPs were first vinyl functionalised by reaction with 3-vinyletriethoxy silane, then imprinted by reaction with Hg(V-Pic)2·2NO3, ethylene glycol dimethylacrylate and azobisisobutyronitrile. Then, 0.1 mol L−1 HCl and 0.1 mol L−1 EDTA was used to remove the Hg ions, leaving the IIP template. A variety of fish digests were analysed by preconcentration and matrix separation using the IIP-MNPs to yield recoveries of between 98 and 102% and an LOD of 0.03 ng mL−1. There are many other reports of SPE using MNPs, but this is a nice example of combining two established technologies in a novel way.
The quantification of polynucleotides particularly lends itself to this type of analysis. For example, Bruckner et al.14 developed a ligation-mediated amplification method for determination of DNA. The tagging reagent was a maleimide-functionalised chelating agent (1,4,7,10-tetraazacyclo-dodecane N,N′,N′′,N′′′-tetra acetic acid, DOTA) complexed with Tb (DOTA–mal–Tb). This reporter molecule is widely used to label oligonucleotides complementary to target DNA sequences, the so-called reporter probe. The target DNA was hybridised with both the reporter probe and another probe, called the capture probe, which had been labelled with biotin. Separation of the hybridised target from excess reagent was then effected in wells coated with streptavidin, by means of the streptavidin–biotin affinity, and subsequent washing. The target complexes were eluted by denaturing in hot nitric acid (or alternatively by using a restriction enzyme) and quantified using ICP-MS to achieve an LOD of 7.2 fmol. This basic assay was modified to include an amplification step in which the reporter and capture probes were ligated together after hybridisation with the target DNA, using DNA ligase, to form a single strand. This strand was detached from the original target DNA by raising the temperature to 94 °C. The temperature was then lowered to 37 °C and the cycle repeated sixteen times, resulting in 6000-fold amplification of the original target DNA sequence in a ligase chain reaction. Subsequent separation and quantification was as before, resulting in an LOD of 2.6 amol, equivalent to 1.6 × 106 copies of the target DNA.
Luo et al.15 developed another approach like this, except using magnetic nanoparticle (MNP) labelled capture probes to effect separation, and reporter probes labelled with a variety of lanthanides to enable a multiplexed assay. This resulted in method detection limits of 28, 48 and 19 amol for the HIV/AIDS viral sequences HIV, HAV and HBV respectively, with recoveries of between 94.2 to 109.1%. They also investigated the rolling circle amplification (RCA) method to improve sensitivity. This works by creating a long strand of DNA attached to the original MNP-labelled target sequence, containing multiple 20 base pair (bp) repeat sequences. Lanthanide labelled reporter probes with complementary 20 bp sequences can then be hybridised, separated from excess reagent, and quantified by ICP-MS. Using this method, they achieved 190-fold signal enhancement for 165Ho, suggesting that 190 rounds were performed after 2 h of amplification. The MDL for HBV was determined to be 90 zmol. A very similar approach, using RCA and MNP capture probes, was developed by He et al.,16 except that they used reporter probes labelled with Au nanoparticles rather than DOTA–Ln complexes. They achieved an LOD of 0.1 fmol L−1 for a synthetic oligonucleotide. Two other papers17,18 describe variations on the aforementioned methods, but without the amplification step. The important point to note is that the amplification step has been the major novel development to emerge since last year's review. This should result in levels of detection which are useful for clinical diagnosis.
It is also necessary to separate the hybridised target molecule from excess reagents. This is usually achieved by using a capture probe, as described in the aforementioned articles. However, this is not possible for the determination of short strands of microRNA, which are only 20–24 nucleotides long, because it is not possible to attach both a capture and reporter probes to such short lengths with high specificity. De Bang et al.19 got around this problem by separating the miRNA targets using gel electrophoresis. They then used a northern blotting procedure to hybridise the separated fragments with complementary DOTA–mal–Ln labelled DNA reporter probes which were an exact match for the target RNA sequences. This yielded LODs of 0.12 ng (18 fmol) and 0.01 ng (1.5 fmol) of miRNA, using LA-ICP-MS and radioactive detection (32P) respectively. The authors speculated that this could be improved by better separation of the excess Ln reagents to eliminate background noise; though evidently this technique would also benefit from an amplification step.
Quantification of proteins is possible either via determination of an endogenous element such as S, P, Fe or Se or by labelling with an elemental tag. Further, the use of IDA offers great accuracy and precision but requires that isotopically labelled analogues of the target molecules are available. This can be achieved either by synthesis of an isotopically enriched analogue of the protein, or by labelling with an isotopically enriched tag.
Schwarz et al.20 have reviewed (90 references) the use of DOTA as a chelating complex for labelling proteins and peptides with metals for the purpose of quantification. They usefully cover the main chemistries available for conjugation of DOTA with proteins, attachment of antibodies for immunoassays, and chelation of the lanthanides with DOTA. They also cover separation and purification steps and the measurement process using ICP-MS, including LA. For anyone wanting to get up to speed on this particular application this is a very concise and useful review. Another review (88 references) by He et al.21 throws its net wider by covering applications of HPLC-ICP-MS using organo-mercury, iodine, ferrocene and metal–chelate complexes. This is probably less useful for the researcher wanting to learn how to apply the technique than the former review because it suffers from being neither comprehensive nor detailed enough. A third review by Campanella and Bramanti22 covers both detection of endogenous metals covalently bound to proteins and elemental labelling. With 248 references, this is clearly the most comprehensive of the three reviews and overviews the different types of chromatographic methods for protein separation, and methods of detection including AAS, ICP-MS, ICP-OES and AFS. Sections are devoted to the determination of proteins containing endogenous Cu, Fe, Se and metallothioneins, and labelling using Hg, I, metallocenes and metal–chelate complexes. The literature is cross-referenced in tables according to ‘sample type’, ‘labelling tag’, ‘separation technique’ and ‘detector’.
If IDA is to be used for quantification of a protein containing an endogenous metal then spiking with an enriched isotope can be performed in one of two ways: either using an inorganic salt; or a synthetically produced isotopically enriched analogue of the target molecule. If the method involves a separation step, such as in LC-ICP-MS, these approaches are referred to a ‘species non specific’ and ‘species specific’ IDA respectively. Konz et al.23 synthesised isotopically enriched 57Fe–ferritin by incorporation of (NH4)257Fe(II)(SO4)2 into apo-ferritin, resulting in Fe:ferritin ratios of about 2200 Fe atoms per ferritin molecule with 92.6% abundance of 57Fe. Analysis by TEM indicated that Fe was incorporated within the protein core as an iron oxide nanoparticle with a diameter of 6.8 nm. Species specific IDA of the standards was performed using SEC-ICP-MS and post-column IDA of S. One of the problems with this approach is that the Fe:ferritin ratio varies, so the same group investigated an alternative approach.24 This involved a sandwich immunoassay with electrogenerated chemiluminescence (ECL) and ICP-MS detection to establish the Fe–ferritin:Ru stoichiometry (1:23), which was required for accurate quantitation. Ferritin was tagged with antibody–[Ru(bpy)3]2+ reporter and antibody–biotin–streptavidin–MNP capture probes. Detection of the[Ru(bpy)3]2 moiety was then performed by both ECL and IDA-FI-ICP-MS using 99Ru as the spike. The method was validated by determination of NIBSC 94/572 ferritin reference material at pmol L−1 levels, with between 85 and 95% recovery.
The preceding discussion well illustrates the problem of not knowing the exact metal:protein stoichiometry in a protein containing an endogenous metal, and the solution now adopted by many workers of using elemental tags for quantification. The tagging approach is attractive because it is based on available technology which has been adapted for this purpose. Liang et al.25 have developed a ‘click chemistry’ approach to simultaneously measure the activity of, and quantify, the enzyme P450 3A4 (CYP3A4). A hexynylated 17α-ethynylestradiol activity-based probe was used to label the CYP3A4 molecule, and also conjugated, via an alkyne group, with an azido-DOTA–Eu complex. In this way, the activity of the enzyme could be assayed via the activity probe, and quantification performed by species unspecific ID-ICP-MS using 153Eu, to achieve an LOD of 20.3 fmol. The method was validated by determination of CYP3A4 in human liver microsome samples to be 1.04 ± 0.05 μM compared with the value of 1 μM given by the producer.
El-Khatib et al.26 developed an Ln–DOTA–dimedone tagging reagent which is specific for peptides and proteins containing sulfenic acid (SA). They also used a lanthanide labelled metal coded affinity tag, with an iodoacetamide conjugation group specific for thiols, (Ln–MeCAT–IA) in a dual labelling strategy for absolute and relative quantification of the proteins using ICP-MS. They proposed that this could be a useful method for the direct comparison of thiol groups and SA for monitoring oxidation in biological samples in the pmol to amol range. Yan et al.27 have used an element-tagged photo-cleavable biotinylated chemical ‘hub’ for absolute quantification and identification of proteins by ICP-MS and ES-MS. The reagent in question comprised: a sulfonyl fluoride guiding group to imbue specificity towards the hydroxyl group of serine residues in serine proteases; Eu–DOTA for quantification by ICP-MS; biotin for separation on streptavidin-coated beads; and a photo-cleavable o-nitrobenzyl ether linker to release the captured protein for ES-MS identification. Clearly, there are an immense number of variations of the tagging techniques which have yet to be reported.
Many of the tagging methods used for quantification of biological molecules are based on immunoassays, a topic which has been comprehensively reviewed by Liu et al.28 They covered the basic theory of immunoassay and the advantages of using metal tags in conjunction with ICP-MS detection. In particular they reviewed the use of nanoparticles and polymeric chelating tags used for signal amplification, the multiplexing advantage, and its use in cell cytometry. The review has approximately 200 references and applications tabulated with respect to analyte, immunoreaction type, elemental tag and LOD. Another review (94 references) by Bjornson et al.29 focussed on applications of cell cytometry using metal tagging in the clinical area. They concluded that improvements in sensitivity, sample flow rate and recovery are still required, but multi-dimensional, single-cell mass cytometry should have a dramatic effect on drug development and therapies.
An immunoassay method for glycoproteins has been developed by Peng et al.30 They used Con A, a glucose and mannose selective MNP–lectin, to capture haptoglobin (HP), hemopexin (HPX) and ovalbumin (OVA), which were then immune-labelled with antibody–polymer multielement tags (Cd, Hg, Pb) for signal amplification and multiplexed detection. Separation of the MNP-immuno-complex from excess reagent was achieved in a magnetic field, then quantified using ICP-MS. LODs of 0.032, 0.027 and 0.13 ng mL−1 were obtained for HP, HPX and OVA respectively. The method was used to determine glycoproteins in real human serum with recoveries of over 97%. An immunoassay for Jurkat T was developed by Zhang et al.31 using MNP-antiCD3 capture probes, Au-NP–antiCD2 reporter probes, and ICP-MS detection. By taking advantage of the amplifying effect of the Au-NP the LOD was 86 cells, which is comparable with electrochemical detection but faster. It is clear that the use of elemental tagging immunoassays with ICP-MS detection has exploded over the review period, and is now competing with conventional molecular mass spectrometry in many biological and clinical applications, which is a great advance for the technology and probably not foreseen when ICP-MS was being developed. Numerous other applications using the same basic format have been published for the quantification of antibodies,32 HIV-1 p24 antigen,33 cytochromes,34 and various biomarkers.35,36
Single particle inductively coupled plasma mass spectrometry (sp-ICP-MS) is an emergent method for detecting, characterising, and quantifying nanoparticles. An introduction to the technique is provided by Laborda et al.38 Despite the somewhat limited number of published applications to date, the relatively simple instrumental requirements, the low detection levels attainable, and the possibility to detect both the presence of dissolved and particulate forms of an element make this methodology very promising in the nanoscience areas. This is reflected in the number of research papers in the area that have been published during the period covered by this review. Linsinger et al. reported on the results of an international intercomparison of particle-size determination by sp-ICP-MS.39 Concentrated monodisperse Ag nanoparticle suspensions with particle diameters of 20, 40 and 100 nm and a blank solution were sent to 23 laboratories in Europe, the USA and Canada. Laboratories prepared eight nanoparticle preparations in two food simulants (distilled water; 10% ethanol) and reported median particle size, Ag particle mass concentration and Ag particle number concentrations. Average repeatability (r) and reproducibility (R) standard deviation for the median particle diameter were 1 and 14 nm, respectively. Relative precision was poorer for Ag particle number concentrations (RSD (r) = 11%; RSD (R) = 78%). The improvements on the method were identified as software tools for evaluation, hardware options for shorter dwell times, calibration standards for determining nebuliser efficiency and further experience by laboratories. However, the results of this study certainly demonstrate the suitability of sp-ICP-MS for the detection and quantification of certain kinds of nanoparticles. Liu et al. carried out a study on sp-ICP-MS for Au nanoparticles from 10 to 200 nm.40 The study concluded that a major improvement in quality of the data results from optimisation of dwell time, with the optimal dwell time (limiting split particle events, particle coincidences and false positives) being 10 ms. Transient features of single particle events were temporally resolved on a quadrupole ICP-MS system using a sufficiently short dwell time (0.1 ms). The linear dynamic size range of the ICP-MS system under standard (highest) sensitivity conditions was 10 to 70 nm but could be further extended to 200 nm by operating in less sensitive modes. Hineman and Stephan also investigated the effect of dwell time on sp-ICP-MS data acquisition quality.41 They noted that nanoparticle events in the plasma are less than 0.5 ms in duration whilst current conventional quadrupole-based ICP-MS instruments are limited to instrument dwell times in the millisecond range and have data acquisition overheads that adversely affects data quality. Novel instrument settings and data processing techniques were used to explore the benefits of continuous data acquisition rates as fast as 105 Hz (or 10 ms dwell times). The authors provided data on the different effects that data acquisition rate has on the quality of data that can be obtained by sp-ICP-MS. The effect of varying the dwell time and its influence on particle integration, particle counting, particle sizing, and background signal was discussed. The relatively poor accuracy obtained in measurement of size and number concentration by sp-ICP-MS was addressed by Tuoriniemi et al.42 The relative contributions of different types of noise to the overall uncertainty during sp-ICP-MS measurements of Ag and Au nanoparticle dispersions were quantified showing that the accuracy of sp-ICP-MS is mainly limited by the uncertainty in nebulisation efficiency. This uncertainty was improved by correcting for analyte partitioning effects during nebulisation. The calculated Ag and Au nanoparticle sizes were in close agreement with sizes determined by SEM. The duration of the particle events was measured, which allowed correction for incomplete particle events and detector dead time, and determination of the effective dwell time for particle counting. The number concentration measured with sp-ICP-MS agreed with that measured by counting particles deposited on filters, and calculated from the mass concentration of the analyte.
Several novel methods of CVG have been reported over the period of the review. Lopez-Molinera et al.45 have investigated the kinetics of the generation of volatile halides of AsIII, GeIV, SbIII–V and SeIV–VI. The method utilised concentrated sulfuric acid to generate volatile fluoride, chloride and bromide species on injection of solutions of analyte and halide. The most rapidly evolved species were AsIII chloride, SeVI bromide and SbV bromide, with appearance times of <1.0 min. Some dependency on halide composition was noted, with chloride species vaporised at medium to high chloride concentrations whereas bromide and fluoride species required low halide concentrations. The sensitivity of ICP-OES detection was dependent on the speed of the reaction and the relative bond strengths of the different halides. Species formed by GeIV and AsIII with chloride, and SbV and SeVI with bromide exhibited the greatest analytical potential. This type of reaction was made use of in a completely opposite sense by Reddy et al.46 who used chlorine gas, generated in situ, to volatilise a Ge matrix as Ge–chloride for the determination of trace impurities by ICP-OES. It was necessary to hold the temperature at 120 °C to ensure complete volatilisation of the matrix. It should be noted that both of the aforementioned methods have significant health and safety concerns, requiring the use of concentrated sulfuric acid and generation of chlorine gas respectively.
Sun et al.47 reported a headspace, liquid-phase, micro-sublimation method for the determination of B by ICP-OES. In a simple procedure, 100 μL of NaOH absorption solvent was placed in the bottom of a 0.5 mL conical tube. 100 μL of sample solution was placed in the lid, the tube capped, and inverted on a hotplate at 70 °C. After 10 h the absorption solvent was analysed for B. They obtained an LOD of 0.008 μg mL−1 and applied the technique to the determination of B in plants and waters, with recoveries of between 98.7 and 105.8%. Another novel development was reported by Rastogi et al.48 who synthesised Cu–bovine serum albumin (Cu–BSA) nanoparticles and used them for cold vapour generation of Hg. The vapour generation reaction was performed in a 1 m PTFE reaction coil maintained at 90 °C, and was thought to be due to reduction of Hg2+ by elemental Cu0. LODs of 2.8 pg and 4.1 pg for iHg and MeHg respectively were obtained using ICP-MS.
Hydrogen plasma assisted CVG of As, Sb, Se and Te has been proposed by Yang et al.49 as a green method because it obviates the need for chemical reagents. In this method, samples were nebulised in the conventional manner in a stream of argon, then passed through the 16 W, hydrogen dielectric barrier discharge (DBD) to generate hydrides, and detected using AFS. The authors speculated that species such as H, H+, H2+ and H3+ were generated in the plasma and acted as reducing agents. After optimisation for argon and hydrogen flow rates, LODs for As, Sb, Se and Te were 0.6, 1.4, 1.2 and 1.0 ng respectively.
Photochemical vapour generation (PVG) is an attractive alternative to CVG because it potentially uses fewer reagents, with formic acid usually being the only reductant necessary. Some researchers have added photocatalysts such as TiO2 to improve the efficiency of PVG. Shih et al.50 developed a photocatalyst device fabricated from poly(methyl methacrylate) and coated with nano-TiO2. The advantage of this is that is does not require repeated loading of the TiO2 substrate. The device, which was only 150 × 28 × 4 mm, was used for PVG of SeIV and SeVI using formic acid (25 mM) as the reagent and UV irradiation (40 W at 365 nm). Coupling with ICP-MS yielded LODs of 0.043 and 0.042 μg L−1 respectively. In contrast, Yang et al.51 used a slurry of TiO2 nanoparticles onto which were absorbed the SeIV and SeVI analytes, with subsequent UV irradiation in the presence of formic acid. In this case the LOD was lower at ∼0.8 ng L−1 but this was using AFS detection. Clearly, immobilization of TiO2 would be the preferred method for future development in order to minimize reagent consumption.
Huang et al.52 combined electrokinetic extraction (EKE) and electrochemical vapour generation (EVG) in a single device for the determination of As species by AFS. The integrated cell was fabricated from two PTFE tubes, linked together to form an ‘H’ shape, with one arm containing a graphite working electrode and the other a Pt auxiliary electrode. In operation the whole cell was immersed in 200 mL of sample to perform the initial EKE, then subsequently removed for EVG, but the exact procedure is not described particularly clearly in the paper. An LOD of 0.020 mg L−1 was obtained for AsV and recoveries for water samples ranged from 98 to 104%.
Micro-hollow cathode GD-OES can be used for analysis of liquid samples as demonstrated by Vander Wal et al. for hydrocarbon determination.58 The same authors applied pulsed mode to analyse? solid materials in the form of dry powders.59 Both molecular and elemental information were obtained from a range of organic materials and fertilizers. Relative intensities of common spectral signatures were used to distinguish biological agents from common benign organic materials. The micro detection system has potential as a portable hazardous materials sensor.
The application of LA-ICP-MS to elemental bioimaging was reviewed by Becker et al.62 The capability of the technique to quantify trace elements and isotopes within tissue sections with a spatial resolution ranging about 10–100 μm offers major applications in the areas of brain and cancer research, animal model validation, drug development and plant science. Improvements in ablation systems, operation and cell design enabled progressively better spatial resolutions down to 1 μm. Blaske et al. applied the technique to the analysis of nanosilver-coated bone implants.63 This work demonstrated that only the high sensitivity and low detection limits of LA-ICP-MS make this determination possible.
Quantitative analysis of biological tissues can be problematic due to variable sample conditions and changing instrumental parameters during measurement time using LA-ICP-MS. Bonta et al. addressed this problem using gold thin films for internal standardisation.64 The gold standardisation was found to compensate for instrumental drifts, matrix related ablation differences and day-to-day signal changes. The RSD of the measurements was around 15% before standardisation and less than 5% using gold standardisation and quantitative information was obtained for samples with previously? unknown analyte concentrations. LODs in the range of hundreds of ng g−1 were achieved. Another approach to internal standardisation and calibration for bioimaging using LA-ICP-MS was proposed by Hoesl et al.65 The procedure was based on printing metal spiked inks onto the top of thin layer samples using an ink-jet printer. The ink was spiked with indium as an internal standard and homogenously printed over the entire membrane prior to LA-ICP-MS detection. An RSD of 2% was achieved. For the printed calibration standard LODs of <4 fmol for different metals and relative process standard deviations of 1–2% were obtained.
The relatively long measurement time required for chemical imaging of relatively large sample areas using LA-ICP-MS was addressed by Wang et al.66 A low dispersion sample chamber (tube cell) was developed to improve the imaging capabilities by reducing the single LA shot duration to 30 ms (full width at 1% maximum). The tube cell is based on a constant laminar flow and a well-controlled delivery of the laser-ablated aerosol into the transport system, leading to minimised tailing of the aerosol washout and helping to separate the signals even at repetition rates as high as 20–30 Hz. To demonstrate the improved imaging capabilities, microstructured metallic thin film patterns were analysed at a spatial resolution of a few micrometers. The LA-ICP-MS results obtained were comparable to synchrotron-based micro-X-ray fluorescence (SR-microXRF). The novel laser LA cell was used to image the distribution of a metal-tagged biomarker in a thin section of breast cancer tissue. Spatial resolution of subcellular (similar to 1 μm) orders was obtained, the level required for morphological assessment in cancer diagnostics.
LA of samples directly into the formed liquid microjunction of a continuous flow surface sampling probe/electrospray ionisation emitter was investigated as a tool for molecular and elemental detection and mass spectrometry imaging.67 The ability to efficiently capture and ionise ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and Ag ion solvent clusters formed from LA of electropolymerised polyaniline and Ag thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 μm was illustrated by using laminated inked patterns on a microscope slide. The data collected demonstrate at least an order of magnitude signal enhancement compared to the noncontact, laser ablation droplet capture-based surface sampling/ionisation approaches previously reported.
A lower cost alternative to conventional laser ablation, using a diode laser, was applied to whole blood analysis by Foltynova et al.68 DLTV-ICP-MS is suitable for quantitative elemental analysis of low volume liquid samples and uses low-cost components: a diode laser, a laboratory-built cell and a strip of filter paper. The aerosol generation by DLTV was carried out in a simple cell made up of a glass tube, a near infrared continuous-wave diode laser and a common syringe pump. The cell is characterised by minimal dead volume, which reduces turbulent flow and provides very fast wash-out. The paper substrate can hold up to 24 samples; an analysis time per sample of similar to 4.7 s was achieved. The device performance was optimised, compared to a commercial ablation system and applied to the determination of lead and cadmium in whole human blood without any sample treatment. A prearranged calibration set was printed on the paper strip using a piezoelectric dispenser.
A novel variation on the plasma-in-solution concept has been developed by Shirafuji et al.72 They constructed a device which had, concentrically, a metal electrode, a dielectric rod-shaped silica pumice (20 mm o.d.), and a glass tube. Argon (1.1 L min−1) was passed through the centre of the electrode then emerged from the pumice as small gas bubbles (much like a degassing stone) into deionised water. Application of a square-wave voltage waveform (amplitude 5 kV, frequency 20 kHz, pulse width 1.2 μs) between the central electrode and a grounding electrode on the outside surface of the glass tube resulted in plasma formation in the bubbles. Time-resolved spectral analysis yielded Trot = 2000 K and Tvib = 3000 K at t = 140 ns, and Trot = 2000 K and Tvib = 7000 K at t = 340 ns. These results reflected the slowness of vibrational compared with rotational relaxation, and the authors note that Tvib is considered to show similar behaviour to Te. Although not used for analytical spectroscopy the device clearly has this potential, with the multiple bubble approach increasing the intensity of emission from the sample medium.
Finally, no discussion of new instrumentation would be complete without mention of a piece of kit designed for being shot into space. Riedo et al.73 have evaluated an LA-MS system for planetary exploration in which the laser beam is directed and focussed into a reflectron TOF-MS where the sample is ablated and ionised in situ. The optimised system was evaluated by Pb isotopic analysis of NIST SRM 98, yielding relative accuracies of e.g. 0.4 per mil for 208Pb and 7.6 per mil for 204Pb at concentrations above 100 ppm. By the authors own admission, elements/isotopes with low abundances had values in the percent range, though further improvements in detector sensitivity and elimination of noise may improve this.
Weiss et al.77 developed a transition rate model of Mn excitation in argon, neon and argon–hydrogen Grimm GDs. The model took into account the rate of population and depopulation of excited states by summing up transition rates of all observed transitions from and into certain energy levels. The authors reached a number of interesting conclusions regarding the excitation and ionisation processes in the GD, and the formation of metastable states of Mn. Chief amongst these was that the Mn(II) emission spectrum most likely arose from asymmetric charge transfer with argon and neon ions and possibly Penning ionisation of manganese atoms and Mn(I) metastables; in the Mn(II) quintet system, transitions from higher lying levels populate some metastable levels; and cascade de-excitation of higher energy levels plays a significant role in the population of lower energy levels from which significant emission occurs. It seems obvious that the excitation and de-excitation rates must be taken into account in order to gain a complete picture of the excited state population, however as the authors point out, considerable experimental work was necessary to accurately identify Mn(I) and Mn(II) lines and obtain accurate emission spectra and ‘true’ line intensities over the spectral range observed.
Yubero et al.78 developed a method of measuring Tgas in a microwave discharge using van der Waals broadening of the Na(I) 588.99 nm line. The more commonly used Ar and Hβ lines are quenched in plasmas containing nitrogen, so this method would be of use for plasmas formed in air or other gases.
Borovinskaya et al.79 have continued their interesting and revealing studies of particle behaviour in ICP-MS. They imaged multielement analyte emission from individual droplets passing along the central channel of the ICP using a side-on spectrometer with CCD detector. Droplets were introduced using a microdroplet dispenser and their emission images correlated with transient signals measured using TOFMS. The basic criterion was the temporal shift in the intensity maximum for a particular ion compared with 89Y+ (which had the earliest occurrence time) obtained by Gaussian fitting of the emission profiles. They found that particles travelling off-axis exhibited greater temporal separation in analyte signal maxima. This was caused by element-dependent fractionation as the vaporised analytes diffused towards the central axis, where the radial velocity gradient continuously separated them in space from the unvaporised droplet residue. Further confirmation of this theory was lent by calculation of the radial velocity profiles of plasma gases and correlation between analyte boiling point and temporal shift, with more volatile analytes being more greatly affected. Another consequence was that the direction of the radial velocity gradient also influenced the order of appearance of the analyte signals for elements of different volatility. This study is a good example of careful observations allied with theoretical calculations, and gives important insights into analyte behaviour in the ICP, particularly for single particle analysis. The same group simultaneously published80 a more detailed computational fluid dynamics study of gas flow and rotational motion in the ICP torch, presumably used to inform the aforementioned paper. The model took into account the three concentric argon gas flows through the ICP torch and sampler cone, held at a fixed depth of 10 mm, and power coupling into the plasma. The plasma species Ar, Ar+, Ar2+ and e− were also included in the model. The main thrust of the research was to optimise conditions of gas flow and power in order to reduce the backward flow of auxiliary gas and to maximise its flow through the region of maximum power coupling. Needless to say, they found that there was an interdependency between the three gas flows, power, and injector tube diameter, and concluded that control of the carrier gas flow rate was the most critical parameter. However, they tempered this with the warning that analyte signal intensity (and presumably interference effects) will also be affected and needs to be taken into account, which is a subject for further investigations. Such models are a useful addition to the diagnostic arsenal for studying the behaviour of the ICP and, allied with empirical observations, yield important insights for the development and optimisation of ion sources for both ICP-MS and ICP-OES.
The DBD has attracted interest as a compact, low-power, microplasma source for MS and AES, following the trend for all things miniature. Shelley et al.81 undertook a diagnostic study in an attempt to better characterise it, using TOF-MS to gain an insight into the temporal formation of ions. They generated a pulsed plasma using a He gas flow of 550 mL min−1 and a 6 kVp–p waveform. Stable operation was achieved at frequencies between 2 and 500 Hz with sine, triangle, sawtooth, and square waves. The intensity and nature of the various ions varied, unsurprisingly, over the course of the pulse. The authors extrapolated conclusions about ion formation from these temporal profiles, based on the coincidence of reagent and analyte ion peaks, but the results were rather sparse and hence inconclusive. Another study of a helium DBD by Horvatic et al.82 focussed on methods to determine Tgas and ne using the Lorentzian width of Hα, Hβ and He lines. They found that Tgas was constant across the capillary and was the same as the room temperature (∼320 K), at atmospheric pressure 6.5 kV and 21.5 kHz operating conditions. They were also able to elucidate broadening parameters of the H lines caused by neutral He to be: γνHe(Hα) = 1.56 × 10−9 cm3 s−1 and γνHe(Hβ) = 3.16 × 10−9 cm3 s−1.
This was a quiet year for furnace fundamentals with only two publications reporting original research. Gupta et al. studied the observed suppression of analyte absorbance in ETAAS in the presence of uranium and thorium matrices.83 Arrhenius plots demonstrated that atom formation was similar in aqueous solution and in the studied matrices. SEM studies, however, confirmed that the interaction of the uranium and thorium with the graphite surface resulted in formation of an uneven surface which affects the atomisation efficiency resulting in a reduced absorption signal. Rogulsky et al.84 used mathematical modelling to predict the mechanism of palladium modifiers in ETAAS.84 The results of the study suggest a desorption mechanism for dissipation of palladium with a direct reaction between palladium and the analyte.
Publications on the use of PMs in ETAAS were reviewed.85 The most commonly used PMs: thermally stable carbides, PGMs, and their mixtures were characterised. The sample types considered included organic solutions, suspensions and solid samples, materials after acid decomposition, and natural and drinking water. Results of physicochemical studies of sorbent modifiers were also discussed.
Molecular absorption spectroscopy (MAS), originally developed in the 1970s, is a technique to determine non-metals in flames and graphite furnaces by monitoring the absorbance of diatomic molecules. Early studies employed low resolution instruments designed for line source atomic absorption, which provided a limited choice of analytical wavelengths, insufficient spectral resolution, and spectral interferences. However, the development of HR-CS-AAS instrumentation has allowed the analysis of challenging samples for non-metals as well as some difficult elements to determine by AAS, such as Al and P. Butcher provided a review covering the theory and the analytical considerations for MAS.86 The benefits of HR-CS AAS instrumentation are defined and significant work in the field highlighted.
Spectroscopic interferences are typically avoided by choosing alternate lines (in ICP-AES) or isotopes (in ICP-MS). Other methods which have been proposed over the years include interference correction (both ICP-AES and ICP-MS) and the use of doubly charged or oxide ions (ICP-MS). More recently, interferences in ICP-MS have been reduced by using some form of reaction cell in tandem with the mass spectrometer. Boting et al.89 have developed a novel approach for interference avoidance by using a reaction cell between two quadrupoles to investigate the exothermic asymmetric charge transfer reaction A+ + O2 → O2+ + A between O2 reaction gas and metastable species of the relevant analyte ions. Using this triple quadrupole system to isolate specific analyte m/z, they observed a linear relationship between the O2+ signal and the concentration of As, Au, B, Be, Br, Cl, I, P and Se, making this a viable technique for the avoidance of spectral interferences on the ions of these elements. They confirmed that the observed signal at m/z of 32 was caused by 16O2+ by repeating the same experiment using isotopically enriched (97%) 18O2. It should be noted that the authors state that the reaction is only exothermic between O2 and the metastable species of the ions studied (otherwise it is endothermic). This fact should be borne in mind when considering the results of Chiba and Narukawa90 who studied the effect of O2 reaction gas on the formation of oxides of As species. They calculated that the reaction As+ + O2 → O2+ + As is endothermic, but that the As+ + O2 → O2+ + AsO+ + O reaction is exothermic, and favoured to the extent of almost 100% conversion. Hence, they observed the formation of AsO+ as a result of introducing O2 in the reaction cell, rather than the formation of O2+. Presumably the particular experimental set-up and reaction conditions have an influence on the relative rates of these competing reactions, and the different observations of these two groups?
The advent of ‘triple quadrupole’ ICP-MS has allowed the analyst to exercise much greater selectivity both pre- and post-reaction cell, thereby allowing a greater range of reaction chemistries to be utilised. Bolea-Fernandez et al.91 have taken advantage of this and used methyl fluoride (10%) with He (90%) as reaction gas to convert Al, Co, Cr, Mn, Ni, Ti, and V into a variety of product ions with lower interferences. Hence, they were able to perform an interference-free, multi-element determination of these metals in biological fluids with LODs below 10 ng mL−1.
The overall detection efficiency of any LIBS system is a function of wavelength; therefore, the instrument must be carefully calibrated over a wide wavelength range. Quartz tungsten halogen lamps are widely used as spectral irradiance and radiance standards due to their continuous smooth emission from 250 to 2400 nm. However, these devices call for expensive recalibration after a certain number of working hours. As an alternative and easy-to-implement way of calibrating the response, Li et al.101 reported the use of the well-known Ar branching ratio. They showed that this method, in a laser-induced argon plasma, provided results fitting well (e.g. similar calibration uncertainty) with those obtained using a standard quartz tungsten halogen lamp and the argon branching ratio method in an argon-filled hollow cathode lamp.
Antenna-coupled microwave-assisted LIBS was studied by Tampo et al.104 to enhance the emission intensity in an attempt to solve the issue of sensitivity reduction in super-high resolution spectrometers, which are required for nuclear fuel analysis. The pulsed microwave input temporally sustained plasma emissions of excited Gd ions for a period of around 300 ms (10 times longer than without microwave coupling). By integrating the temporal emission of excited Gd ions, a 50-fold increase in emission intensity was achieved. Likewise, Liu et al.105 investigated flame-enhanced LIBS to improve the sensitivity and spectral resolution by generating a laser-induced plasma in the blue outer envelope of a neutral oxy-acetylene flame. In particular, a high-temperature and low-density plasma was generated, providing enhanced emission line intensity and narrowed lines in the LIBS analysis of low alloy steel targets.
Novel LIBS methods were also investigated to improve the determination of halogen elements, which provide some difficulties due to their high ionisation potential. For example, Álvarez et al.106 investigated the development of a LIBS method to determine the fluorite (CaF2) mass-content of powdered ore samples. This method was based on the LIBS detection of different CaF molecular bands in ambient air conditions, and it was shown as an alternative to the use of atomic fluorine emission lines (e.g. F(I) at 685.60 nm) in a helium atmosphere. Zhang et al.107 investigated iodine detection of CH3I in buffer gases of N2, using low pressure LIBS under different experimental conditions. In particular, it was demonstrated that it was possible to achieve a low detection limit (about 60 ppb) for iodine in N2, using low pressure (700 Pa) ns-LIBS and integrating the iodine emission signal at 183 nm.
The capabilities of LIBS for 2D and 3D analysis were investigated by several authors. In particular, Beresko et al.108 demonstrated the possibility of performing 3D multielemental chemical maps of complex-shaped surfaces without any additional equipment for the determination of the best focal position. Direct monitoring of the LIBS signal intensity was used to correct the focusing lens-to-sample distance. This method allowed the scanning of surfaces with large height fluctuations (i.e. mm) without the need of any additional devices, and improved the measurement reproducibility. LIBS might be also applied for depth profiling of thin coatings due to the possibility of achieving very shallow ablation depth per pulse (e.g. a few nm per pulse). Nevertheless, the depth resolution might be much higher than the ablation depth per pulse due to non-uniform emitted spectra over several laser shots. In this context, Banerjee and Fedosejevs109 investigated whether the observed spectrum obtained for single laser shot ablation reflects the average composition of all the material ablated, or whether materials close to the top surface contribute more to the emission. Their results showed that plasma formed at the surface layer exhibited a strong LIBS signature while the deeper melted layer contributed very little to the single shot LIBS signal. Therefore, the emission spectra did not necessarily reflect the actual average depth profile composition in single shot LIBS.
The LIBS technique is known to be able to provide quantitative analysis. Nevertheless, strong matrix effects can degrade the precision and accuracy. In this context, Glaus and Hahn110 reported the application of double-pulse laser ablation (DP-LA) to improve the analyte response and the achievable precisions of LA-LIBS, which is an analytical method that minimises sample matrix effects. Two coaxial laser beams were directed at the ablation site and the analytical signals were then collected from a LIBS plasma downstream of the ablation site. This enhanced ablation yield and produced, to some extent, a finer aerosol structure which was more efficiently vaporised and dissociated in the analytical LIBS plasma. A linear response was observed for Mn across the different matrices (except for Al samples), allowing for non-matrix-matched calibrations. Furthermore, D'Andrea et al.111 developed an approach based on ANN for LIBS quantitative analysis. A preliminary step of dimension reduction was used to achieve the desired accuracy while minimising the complexity of the approximating neural model. In particular, the number of input variables (e.g. intensities of spectral lines) was reduced to the minimum using forward feature selection. Acceptable values of trueness accuracy and precision for the analysis of bronze alloys were achieved in a way that the analysis could be easily automated. It was considered that this quantification method has great potential for the continuous monitoring of the composition of large numbers of metal samples in industrial applications.
An improved method to measure the isotopic ratio of boron samples with high precision was investigated by Sarkar et al.112 using laser ablation molecular isotopic spectrometry (LAMIS). Different spectral normalization and pre-treatment procedures were applied to the raw spectra and analyzed by PLSR. First order differentiation of the spectra followed by normalizing with respect to the highest value was found to give optimum precision. A precision of 9‰ (2σ) on the boron isotopic ratio was achieved using 1000 single shot LAMIS spectral accumulation.
In relation to LIBS analysis under water, Hou et al.113 investigated the analysis of natural seawater at different pressures (from 0.1 to 40 MPa) in order to demonstrate the potential of this technique for in situ analysis at 4000 m depth in the ocean. Plasma emission was found to be slightly dependent on the ambient pressure during the early stage of plasma but the external pressure significantly affected plasma emission during the late stage. In the same context, SP-LIBS and DP-LIBS with a collinear laser beam orientation were investigated by Lawrence-Snyder et al.114 for high-pressure bulk aqueous solutions (up to 50 bar). In SP-LIBS the plasma forms in a static liquid environment while the DP-LIBS plasma forms in a dynamic bubble environment which is significantly influenced by solution pressure. The results showed that DP -LIBS emission intensity was directly proportional to the size of the laser-induced bubble, at all evaluated pressures. Nevertheless, high solution pressures confined the expanding bubble to a greater extent, causing the bubble to collapse earlier (decreasing the bubble lifetime), which in turn prevented the bubble from reaching the maximum volume observed at lower pressures.
An extremely sensitive and simple fiber loop-cavity ringdown spectroscopy setup was designed by Berberoglu and Altan,117 using a pulsed nanosecond laser source working near 1535 nm (e.g. C-band window). The system sensitivity was found to be of the order of 0.01 dB after extracting the characteristic macrobend loss curve of a standard single mode fiber (SMF-28). It was claimed that this simplified CRDS system might have a great potential in versatile applications (e.g. detection of some trace gases like ammonia) where quick results are necessary without the system complexity.
Resistors of different magnitudes are becoming a must-have accessory for Faraday cup amplifiers on multi-collector mass spectrometers. Standard-issue 1011 Ω resistors are capable of translating ion beams between 5 × 1013 A and 4.5 × 1010 A. However, for simultaneous measurement of large and small magnitude isotopes a lower order resistor (e.g. 1010 Ω) for the larger beam may be appropriate, especially where sample size is unrestricted. Higher precision on large magnitude ratios, for example 238U:234 or 235U with limited analyte, can potentially be achieved using a higher impedance resistor (e.g. 1012 Ω). Development and testing of newly manufactured 1013 Ω resistors were documented by Koornneef et al.,120 which in theory have 10 times lower noise levels than the 1011 Ω variant. Trials using Sr and Nd loads of 10 pg via TIMS indicated that 87Sr:86Sr and 143Nd:144Nd could be resolved to the fourth decimal place of their ratios (i.e. ±3.3‰). A cautionary note raised by these authors is that at such sample concentrations, the level of procedural blank becomes of paramount importance to the accuracy of the measured isotope ratio.
Ireland et al.121 introduced a new all-Teflon HPLC system. This was developed in response to the need for an automated chromatographic system that combined fine-scale gradients in acid strength and permitted highly concentrated acids. Potential applications in the geoscience field include Ni–Mg separation for Ni–60Fe studies and separation of individual multi-isotopic REEs.
Yin et al.124 experimented with AMS measurement of uranium in 5 ng samples. They reported a consistent agreement of measured 234,235,236U:238U relative to certified ratios for internal standards, with ratios spanning four orders of magnitude. AMS is commonly used for U and Pu analysis, but Christl et al.125 examined the potential for extending analysis to the higher actinides: Am and Cm. Their results indicated that detection limits for 241Am and the Cm isotopes were in the range 1 fg to 100 ag respectively, potentially opening the AMS technique to bioassay applications. A 237Np measurement protocol by AMS was outlined by Wang et al.,126 with sensitivity reported as <10−11 on 237Np:238U.
Post Fukushima, 134Cs:137Cs has been used as a tracer of environmental contamination. However, the short half-life of 134Cs encouraged Zheng et al.127 to examine the use of 135Cs:137Cs as an alternative for longer-term monitoring. A protocol that involved ammonium molybdophosphate Cs adsorption, chromatographic separation and ICP-MS/MS was used for 135Cs and 137Cs measurement. The reported detection limits, 0.01 pg mL−1 and 0.006 pg mL−1 respectively, are the lowest for any ICP-MS study to date.
Detection of anthropogenic nuclear isotopes at picogram levels is often an expensive and prolonged procedure. Ezerinskis et al.128 described a method to evaluate the abundance of 129I using ion chromatography combined with ICP-SFMS. Their procedure proved reliable for quantification of 129I with a detection limit of 0.7 pg g−1. Uranium isotope measurement of micrometre-scale particles was the subject of a study by Hubert et al.129 A femtosecond laser-ICP-MS combination optimised for laser shot repetition rate produced reproducibility of 238U:235U better than 4% from <200 pg U. Individual 1 μm plutonium particles have been analysed via HR-ICP-MS by Miyamoto et al.130 with the objective of measuring the time since last Pu purification. HR-ICP-MS and a 243Am spike were used to determine the age, which could be constrained between uncertainties of 2 and 6 months. This is thought to provide suitable constraints on environmental samples in nuclear safeguard inspections.
Uranium isotope ratio measurement by TIMS was revived by Quemet et al.,131 who used a total evaporation method. Their results indicated that reproducibility for 234U:238U and 235U:238U was better than 0.5% and 0.1% respectively, on sample sizes of 50 ng.
Recent investigation into the natural variations of uranium isotope ratios was continued by Uvarova et al.132 Their study examined the δ234U and δ238U systematics of uranium ore deposits using 233–236U double spike and MC-ICP-MS. δ234U ratios should be in secular equilibrium (δ234U ∼ 0‰) and deviations from this were attributed to recent (<2.5 Ma) leaching or addition of 234U. Isotope fractionation of 238U:235U was identified amongst the ores from different types of deposits, and was found to vary in response to the redox state of the depositional environment and the isotopic signature of the metallogenic source material. An application of these was suggested as the use of δ238U as an indicator of ore-grade with a trend to lighter ratios in proximity to the redox centre. Murphy et al.133 examined natural uranium isotope variation in groundwaters and mineralised sediments in the proximity of a sandstone-hosted uranium ore deposit. 238U:235U variation between 2‰ and 5‰ in the water was attributed to a unidirectional kinetic isotope fractionation. A progressive shift to lighter isotope compositions in the water was associated with precipitation of uranium-bearing minerals.
Taylor et al.135 provided a re-assessment of the precision of lead isotope measurement by multi-collector mass spectrometry, and examined methods for further enhancement in the future. Four methods of mass fractionation correction were assessed: constant f, Tl-spiking, double/triple-spiking and sample-standard bracketing. Of these, the poly spiking methodologies clearly provided the highest quality data (±0.01% on 206Pb:204Pb). Beyond this, the paper examined the prospects for enhancing the measurement precision of Pb isotopes in Earth sciences via multiple analysis and high impedance resistors in the detection system. This potential was demonstrated using the isotopic averages of several rock units from a single volcano. Average values from all units were found to lie on a remarkably tight trend, not apparent from individual analyses. An outcome could be well constrained mixing lines with tightly defined end member isotope compositions. Dronov and Schram136 provided a method for improved Pb and Sr isotope measurement using quadrupole ICP-MS. By measuring a stepped concentration series of an element, isotope ratios were formulated as the gradient of the line between the two varying isotope signals. Results were presented as per mil deviation from a reference material, and indicated that reproducibility was ±0.07% for 207Pb:206Pb ratios.
In situ measurement of isotope ratios on planetary surfaces requires a suitably miniaturised analytical system, capable of useful precision. Riedo et al.73 described the results for Pb isotope measurement via laser ionisation followed by a reflector-type time-of-flight mass analyser. Measurement precision of 0.02% for 207Pb:206Pb was determined for NIST SRM 981 and galena analysis, which compares favourably with non-double spike TIMS analysis.
Dating of mineral phases using U–Pb systematics is a continuously improving field, exemplified by Chew et al.137 These authors have evaluated accessory mineral U–Pb geochronology by LA-ICP-MS using apatite and titanite of known ages. The novel aspect of their method was the approach to common Pb correction using the Iolite data reduction software. This allowed for variable amounts of common Pb in the accessory phase, and produced uncertainties ±1% for apatite ages between 30 and 500 Ma.
Determination of 143Nd:144Nd in the same analysis as Sm:Nd can be completed by IDA if a correction is made for isotopic overlaps from the added spike. However, Cheong et al.138 have assessed the potential for combined 143Nd:144Nd–Sm:Nd measurement to be made by MC-ICP-MS without recourse to spiking: Sm:Nd being calibrated externally by standard sample bracketing. Results for RMs agreed well with recommended values provided a matrix-matched external standard was used in place of an aqueous standard solution.
Producing higher precision isotope ratios with diminishing elemental concentrations is a motive for achieving increased sensitivity. As such, Crocket et al.139 have re-invigorated the measurement of Nd isotopes in oxide form via TIMS with the aim of improving the isotopic characterisation of fossil corals. Using Eichrom RE-spec and Ln-spec separations followed by focussed filament loading, ion beams of 6 × 1012 A ng−1 were achieved. Interferences from other rare earth oxides were removed using 16O:17O:18O systematics for their laboratory. External reproducibility of coral 143Nd:144Nd was determined as ±16 ppm (2 s) with between 10 and 30 ng sample loads.
Konter and Storm140 tackled the sticky problem of 87Sr:86Sr measurement by MC-ICP-MS. TIMS remains the method of choice to measure this radiogenic isotope ratio due to 84Kr and 86Kr isobaric interferences in plasma-based systems. The authors developed a within-run deconvolution of 84Kr from 84Sr in order to estimate 86Kr on 86Sr and then an exponential Sr mass fractionation correction. Long-term precision of NIST SRM 987 87Sr:86Sr was ±16 × 10−6, which compares favourably with typical TIMS reproducibility.
Faraday cups equipped with amplifiers other than the “standard issue” 1011 Ω variant are expanding the possibilities of measuring samples with low concentrations of the element of interest or with large magnitude isotope ratios. Liu and Pearson141 provided an assessment of the use of 1012 Ω amplifiers in measuring Os isotope ratios as oxides on N-TIMS. A useful function of this study is a clear evaluation of the amount of Os required to generate a particular ion beam size and, in turn, the expected reproducibility error under these conditions. Errors of better than 50 ppm on the 187Os:188Os and 186Os:188Os were generated from 1–3 ng loads, with little degradation in data quality down to 0.1 ng Os.
Like more traditional stable isotope elements (O, S, C etc.), understanding the processes that drive mass dependent and mass independent fractionation requires an appreciation of chemical physics. This was the subject of a timely review by Eiler et al.142 who assessed our current knowledge base in this field using examples taken from the O, Sand C isotope systems.
An interlaboratory comparison of boron isotope measurement was the focus of a study by Foster et al.143 Data from a coherent set of samples was reported from two negative ion TIMS and two MC-ICP-MS instruments in different laboratories. Low-matrix samples, i.e. effectively pure boron, produced comparable δ11B between the laboratories, with differences falling within the range of measurement uncertainty for the laboratories. However, CaCO3−rich samples gave a spread of δ11B which was larger than the expressed uncertainty. Despite this, the high-matrix samples measured in individual laboratories were found to have consistent δ11B offset. This indicated that determinations made within each laboratory would preserve the relative δ11B differences between samples.
A direct injection nebulisation system linked to MC-ICP-MS was used by Louvat et al.144 to assess boron isotope analysis. A key advantage of this method was the high sample throughput, short wash-out time and continuous peristaltic pump operation, meaning tighter sample-standard bracketing and greater instrument stability between analyses. Repeatability for boric acid solutions was <±0.1‰ at 2 s, but was found to be ±0.2‰ for natural samples processed through chemical separation.
Separation of boron from silicate samples using a micro-sublimation technique was investigated by Pi et al.145 Concentrated NaCl solution was added to dissolved silicate rocks, which significantly reduced the Si content of the vapour phase while preserving a high B recovery. Excluding a chromatographic separation of B also reduces the acid-derived procedural blank.
Berman et al.146 provided a perspective on oxygen isotope analysis by Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). For water standards this technique was demonstrated to have a similar precision to conventional mass spectrometric analysis. However, it has a major advantage in completing isotope measurement on liquid water without conversion. Rapid, multiple analysis of δ17O and δ18O enabled reproducible values for 17O-excess (where 17O-excess = ln{δ17O + 1} − 0.528ln{δ18O + 1}), potentially expanding the use of this parameter in studies of the water cycle, atmospheric convection, and climate modelling. Initial measurements of D:H, δ17O and δ18O in water were reported by Wu et al.147 using a compact isotope ratio laser spectrometer. These workers predicted further improvements in the precision of this instrumentation with refinement to the sample introduction system and control of temperature drift in the gas cell.
A timely review of Mg isotope analysis via MC-ICP-MS by An and Huang148 examined the properties of the four main commercial instruments, assessed the chemical isolation techniques, and summarised the key isobaric interferences that can plague Mg isotope determinations. Of most interest is the tabulated and graphical compilation of Mg isotope data for RMs and rock standards in which the compiled data is traceable to a specific publication and measurement laboratory. This review is particularly pertinent as it provides a partial answer to the request of Brand et al.149 for new anchor values for stable isotope delta parameters for secondary isotopic RMs, particularly for the heavier (>20 amu) elements. Issues with Mg isotope measurement were investigated by Teng and Yang150 who used two MC-ICP-MS instruments in their study. Influence of matrix-matching between samples and standards, host acid molarity and Mg concentration were all found to have an influence on δ26Mg; effects that were found to be considerably different between the two instruments. Wet plasma sample introduction was found to have a reduced matrix effect compared to a dry plasma system.
Using MC-ICP-MS to determine sulfur isotope ratios is hampered by an array of isobaric interferences from double charged and polyatomic species. Lin et al.151 overcame these issues using a medium mass resolution (m/Δm ∼ 3000) and matrix matched standards. This approach enabled highly reproducible δ34S to be measured on water samples (including seawater) without chemical purification.
Lehn et al.152 reported a best practice method for measuring δ44/40Ca by TIMS using a 43Ca–42Ca double spike. Optimisation modelling of double spike mixing proportions and measurement parameters was tested on standards. Results indicated an external reproducibility of ±0.04‰ (2σSD), which is a two to ten-fold improvement on previous double spike TIMS methods.
High-resolution titanium isotope systematics were the subject of a study by Millet and Dauphas153 using MC-ICP-MS in conjunction with a 49–47Ti double spike. An interesting facet of their double spike analysis is the recognition of Ti isotope fractionation during chemical purification via the difference noted with bracketed standard-sample β factors. However, the addition of double spike prior to sample preparation reliably accounted for this effect. Precision of the method is reported as 0.02‰ for δ49Ti, with data quoted relative to a new isotope reference standard: OL-Ti.
Interference from oxides and nitrides is a particular issue with the accurate determination of 53Cr and 54Cr systematics. Schiller et al.154 reported a four-step column chromatographic procedure of Cr isolation prior to measurement. Isobaric interferences from 40Ar16O and 40Ar14N were minimised by sample desolvation where trifluoro-methane (CHF3) is used as a supplementary gas and by using a Jet sampler cone and skimmer H-cone in a MC-ICP-MS. The largest 52Cr signal was monitored using a 1010 Ω resistor to allow >50 V beam intensities, while a 1012 Ω variant was used for the small 49Ti and 56Fe signals. Results indicated that reproducibility was better than 54Cr ±5.8 × 10−6 although more sample was required than during traditional TIMS analysis.
Iron isotope compositions of minerals determined by laser ablation MC-ICP-MS was the focus of a study by d'Abzac et al.155 These workers captured particles of natural magnetite, siderite, pyrrhotite and pyrite induced by a femtosecond laser, for imaging and Fe isotope measurement by solution nebulisation. Results are particularly interesting as each mineral produced a different distribution of 56Fe:54Fe with respect to particle size. Larger particles generally had heavier-biased Fe than smaller, but mass difference/size distributions were found to be mineral-specific, e.g. pyrite showed much less laser-induced fractionation relative to magnetite. Differences between the mass fractionation behaviour of ablated mineral species is ascribed to the timing of element condensation in the laser-induced plasma: sulfur-bearing minerals such as pyrite restrict the early condensation of Fe and suppress Fe isotope fractionation.
The problem of measuring Cu and Fe isotope compositions on samples with low concentrations of these elements has been tackled by Costas-Rodriguez et al.156 Essentially a standard addition principle was used in mixing a known isotope ratio solution with the sample solution, both of known Cu concentration. Resulting mixed δ65Cu values for the sample agreed with the Cu isotope ratio determined by conventional bracketing techniques at higher sample concentration.
Cu and Fe isotopes were separated in a single-step chromatographic procedure by Liu et al.157 prior to MC-ICP-MS analysis. The authors documented a long-term reproducibility of better than ±0.05‰ for both δ65Cu and δ56Fe and used the procedure to evaluate the Fe and Cu isotopic characteristics of igneous rock standards. Fe isotopes of these rocks were found to be relatively uniform whereas δ65Cu had a range of 0.4‰. This range extended from ∼0 δ65Cu for BIR-1 (Icelandic basalt), through to +0.3 for BCR-2 (Colombia River basalt) and to +0.4 for GBW07122 (China amphibolite).
Petit et al.158 examined the effects of residual Ti and Cr, remaining after anion-exchange separation, on MC-ICP-MS copper isotope measurement. Experiments showed that Cu and Zn isotope ratios were affected by synthetic and rock matrices which modified the amount and proportion of spectral interferences from Ti and Cr oxides and hydroxides. Their results indicated that Cu:Ti:Cr need to be equal to or lower than 1000:10:3, following chromatography, to negate these effects.
High precision Zn isotope measurement in humans was the subject of a study by Larner et al.159 Blood samples were analysed to trace uptake of 68Zn from ZnO nanoparticles in sunscreen. The results indicated that stable isotope labelling combined with MC-ICP-MS is a robust method for tracing metals in biological matrices.
Selenium isotopes in organic-rich shales were measured by Stueken et al.160 using MC-ICP-MS. Double spiking adjustment of mass fractionation is common practice for Se isotope systematics, but this study investigated a standard-sample bracketing correction. The advantages of bracketing were that five of the six Se isotopes could be determined, enabling a multi-isotope examination of mass-independent fractionation and isobaric interference. A potential disadvantage of standard-sample bracketing recognised by the authors was that the precision is slightly worse than double spiking. Additionally, as the bracketing technique requires a full recovery of selenium through chemistry, this study also recommended modifications to the digestion and chemical separation procedure.
Neymark et al.161 documented the determination of stable strontium isotope variation in natural materials by TIMS. A 207–204Sr double spike corrected for chemical and instrumental mass fractionation, resulting in δ88:86Sr reproducibility better than 0.02‰. Results from biogenic materials revealed the widest range in δ88:86Sr recorded to date (∼2.4‰).
Mayer and Wieser162 determined an absolute isotopic composition for molybdenum in an SRM. This was achieved by gravimetrically and instrumentally calibrating the absolute ratios of a 92–98Mo double spike. In turn, this spike was mixed with NIST SRM 3134 to determine all Mo isotope ratios and the atomic weight interval of this standard by MC-ICP-MS. Molybdenum isotope fractionation during chromatography has been examined by Malinovsky and Vanhaecke163 with a view to assessing the potential for refining the purity of enriched isotope fractions. Anion exchange column separation of Mo solutions demonstrated a heavy Mo isotopic bias at the front of the absorption band during elution. However, the calculated column distance required to produce a workable enrichment in Mo isotopes – an increase from 98.2% to 99.9% was found to be >400 m. Results also indicated that all Mo isotopes behave in a mass-dependent manner during the chromatographic process.
Te is a rare element in the Earth's crust, but has a much higher cosmic abundance; hence studies of Te isotopics tend to concentrate on meteorites. Fukami and Yokoyama164 presented a refined method for the chemical separation of Te and the determination of isotope ratios by TIMS. Around 250 ng of Te was ionised in analyses of standards, with detector normalisation completed using a multi-dynamic routine. Several meteorites and a terrestrial lava sample were measured to test the techniques, which demonstrated that δTe was identical in all analyses. Fornadel et al.165 have also investigated the chemical separation and isotope measurement of Te, this time using MC-ICP-MS. This study examined the stable isotope systematics of Te metal and tellurides in ores from Australia and USA using MC-ICP-MS. Around 1 μg Te was aspirated in each analysis. Findings indicated that the Te isotopes across all of the samples studied had δ130:125Te in the range −1.0 to 0.6‰ (±0.1‰), with some individual mines spanning 0.5 delta units.
Isotope fractionation during column chemistry was tested by Miyazki et al.166 who examined the possibility of high-precision stable isotope measurement of barium. These authors did not identify any Ba isotope fractionation on column recovery of 89% within the bounds of the measurement uncertainty (δ137:134Ba ± 0.025‰). Mass dependent fractionation during MC-ICP-MS analysis was corrected using a 130–135Ba double spike and mass-independent fractionation was accounted for by standard-sample bracketing. The δ137:134Ba precision documented in this study is a factor of five better than achieved previously and was sufficient to identify differences between three igneous rock reference standards (JB-2, JA-2 and BHVO-2).
A new element to be assessed as a stable isotope tracer of natural processes is Nd. Initial analytical methods for Nd stable isotope measurement by MC-ICP-MS without the use of double spiking have been presented by Ma et al.167 Their work examined the chromatographic and instrumental pitfalls of Nd measurement; namely achieving maximum recovery during isolation and correcting for mass fractionation and isobaric interferences. Results indicated that standard-sample bracketing methodology produced errors on ε146Nd and ε148Nd of <0.2 and 0.5 respectively (2SD). Rock standards were found to have ε146Nd ranging from −2.65 for a stream sediment (JSD-1) through to +2.12 for a granodiorite (JG-1a).
2D | Two dimensional |
3D | Three dimensional |
AA | Atomic absorption |
AAS | Atomic absorption spectrometry |
AES | Atomic emission spectrometry |
AF | Atomic fluorescence |
AFS | Atomic fluorescence spectrometry |
AMS | Accelerator mass spectrometry |
ANN | Artificial neural network. |
BCR | Community bureau of reference |
CCD | Charge coupled detector |
CCP | Capacitively coupled plasma |
CRM | Certified reference material |
CRS | Cavity ringdown spectroscopy |
CS | Continuum source |
CV | Cold vapour |
CVG | Chemical vapour generation |
DBD | Dielectric barrier discharge |
DC | Direct current |
DLTV | Diode laser thermal vaporisation |
DMA | Dimethylarsinic (include oxidation state if known) |
DOTA | 1,4,7,10-Tetraazacyclo-dodecane N,N′,N′′,N′′′-tetra acetic acid |
DPLA? | Double-pulse laser ablation |
ES-MS | Electrospray mass spectrometry |
ETV | Electrothermal vaporisation |
ETV-AAS | Electrothermal vaporisation atomic absorption spectrometry |
ETV-ICP-MS | Electrothermal vaporisation inductively coupled plasma mass spectrometry |
EVG | Electrochemical vapour generation |
FHG | Fourth harmonic generator |
FID | Flame ionisation detection |
FTS | Fourier transform spectrometry |
GD | Glow discharge |
GD-MS | Glow discharge mass spectrometry |
GF-AAS | Graphite furnace atomic absorption spectrometry |
HPLC-ICP-MS | High performance liquid chromatography inductively coupled plasma mass spectrometry |
HR | High resolution |
ICP | Inductively coupled plasma |
ICP-AES | Inductively coupled plasma atomic emission spectrometry |
ICP-MS | Inductively coupled plasma mass spectrometry |
ICP-OES | Inductively coupled plasma optical emission spectrometry |
ICP-QMS | Inductively coupled plasma quadrupole mass spectrometry |
ICP-TOF-MS | Inductively coupled plasma time-of-flight mass spectrometry |
ID | Isotope dilution |
IDA | Isotope dilution analysis |
ID-ICP-MS | Isotope dilution inductively coupled plasma mass spectrometry |
ID-MS | Isotope dilution mass spectrometry |
iHg | Inorganic mercury |
IL | Ionic liquid |
IRMS | Isotope ratio mass spectrometry |
KED | Kinetic energy distribution |
LA | Laser ablation |
LA-ICP-MS | Laser ablation inductively coupled plasma mass spectrometry |
LA-MC-ICP-MS | Laser ablation multi-collector inductively coupled plasma mass spectrometry |
LAMIS | Laser ablation molecular isotopic spectrometry |
LA-SF-ICP-MS | Laser ablation sector field inductively coupled plasma mass spectrometry |
LC | Liquid chromatography |
LDGD | Liquid phase diaphragm glow discharge |
LIBS | Laser induced breakdown spectroscopy |
LIF | Laser induced fluorescence |
LOD | Limit of detection |
LOV | Lab-on-a-valve |
MAS | Molecular absorption spectroscopy |
MC-ICP-MS | Multi-collector inductively coupled plasma mass spectrometry |
MeHg | Methyl mercury |
MIP | Microwave induced plasma |
MMA | Monomethylarsenic |
MNP | Magnetic nanoparticle |
Nd:YAG | Neodymium doped:yttrium aluminum garnet |
n e | Electron number density |
NELIBS | Nanoparticle enhanced LIBS |
NP | Nanoparticles |
Od | Outer diameter |
OPA | Optical parametric amplifier |
PGM | Platinum group metals |
PLS | Partial least squares |
PLSR | Partial least squares regression |
PM | Permanent modifiers |
ppb | Parts per billion (10−9) |
ppm | Parts per million (10−6) |
ppq | Parts per quadrillion (10−15) |
ppt | Parts per trillion (10−12) |
PVG | Photochemical vapour generation |
Q | Quadrupole |
QCL | Quantum cascade laser |
SF | Sector field |
SHS | Spatial heterodyne spectrometer |
SIMS | Secondary ion mass spectrometry |
Sp | Single particle |
SPME | Solid phase microextraction |
T e | Electron temperature |
T gas | Gas temperature |
TIMS | Thermal ionization mass spectrometry |
T ion | Ionisation temperature |
TOF | Time-of-flight |
TP-LIF | Two photon laser induced fluorescence |
TS | Thomson scattering |
UV | Ultraviolet |
VG | Vapour generation |
VNIR | Visible and near infrared reflectance |
VOC | Volatile organic carbon |
This journal is © The Royal Society of Chemistry 2015 |