Issue 8, 2011

Minor elements determination and evaluation of diffusion/segregation effects on ultra-thin layers using pulsed-RF-GD-TOFMS

Abstract

Depth profile analyses of ultra-thin layers and their interfaces are investigated, using an innovative Pulsed-radiofrequency Glow Discharge Time-of-Flight Mass Spectrometer (pulsed-rf-GD-TOFMS), to obtain information about the presence of minor elements and to evaluate segregation/diffusion processes at the interfaces. A series of ultra-thin Nb/Al1−xCox bilayers, deposited on Si wafers by dc-magnetron sputtering, is analyzed. An Al1−xCox layer is first deposited on the Si substrate with controlled constant thickness (tAlCo = 6 nm), and different stoichiometries (Co atomic concentration, x = 0, 0.015, 0.035, 0.045, 0.09, 0.35). Then, a Nb layer is deposited on top of the AlCo one, with a thickness tNb = 50 nm that is also kept constant along the whole series. Qualitative depth profiles of those layered sandwich-type samples are determined using our pulsed-rf-GD-TOFMS setup, indicating segregation of Al and Co and diffusion of Co into the Si substrate, as a function of the Co atomic concentration in the AlCo internal layer. Additionally, a linear calibration curve was achieved plotting the Co atomic concentration versus the total integrated Co ion signal, allowing the Co quantification in ultra-thin layers (∼6 nm). Moreover, Secondary Ion Mass Spectrometry (SIMS) was used as a reference technique to validate the high analytical potential of pulsed-rf-GD-TOFMS for the analysis of ultra-thin layers and interfaces. The comparative analytical performance of both techniques is discussed.

Graphical abstract: Minor elements determination and evaluation of diffusion/segregation effects on ultra-thin layers using pulsed-RF-GD-TOFMS

Article information

Article type
Paper
Submitted
25 fev 2011
Accepted
03 mai 2011
First published
25 mai 2011

J. Anal. At. Spectrom., 2011,26, 1604-1609

Minor elements determination and evaluation of diffusion/segregation effects on ultra-thin layers using pulsed-RF-GD-TOFMS

J. Pisonero, A. Licciardello, A. Hierro-Rodríguez, C. Quirós, A. Sanz-Medel and N. Bordel, J. Anal. At. Spectrom., 2011, 26, 1604 DOI: 10.1039/C1JA10075K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements