Issue 7, 2014

Characterization of calcified reference materials for assessing the reliability of manganese determinations in teeth and bone

Abstract

As interest increases in human biomonitoring for exposure to manganese (Mn) via analysis of bone and teeth, there is a growing need for calcified reference materials (RMs) certified for Mn content. Here, several existing calcified RMs and synthesized hydroxyapatite (HA) RMs were digested with acid and subsequently analyzed for Mn by graphite furnace atomic absorption spectrometry (GFAAS) and dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS). Based on GFAAS and DRC-ICP-MS results, mean values and expanded uncertainties were assigned to four New York State (NYS) Bone RMs (05-01 through 05-04), and six synthesized HA standards. Consensus values and expanded uncertainties for Mn content were assigned to NIST SRM 1400 Bone Ash (16.5 ± 2.3 μg g−1) and NIST SRM 1486 Bone Meal (1.1 ± 0.5 μg g−1) by combining GFAAS and DRC-ICP-MS results with literature values. These powdered RMs were also prepared for solid sampling techniques by pressing them into pellets for subsequent analysis by laser ablation (LA-) ICP-MS. The “dilution” effect from adding a chemical binder to the pellets was quantified by both GFAAS and DRC-ICP-MS, and the decrease in Mn mass fraction was found to be proportional to the amount of binder added. The distribution of Mn across the RM pellets was determined by LA-ICP-MS to assess homogeneity and suitability for use as solid standards. The bone RMs were more heterogeneous than the synthesized HA RMs, but the latter may be a less optimal matrix-match due to the absence of organic material.

Graphical abstract: Characterization of calcified reference materials for assessing the reliability of manganese determinations in teeth and bone

Article information

Article type
Paper
Submitted
07 fev 2014
Accepted
04 abr 2014
First published
15 abr 2014

J. Anal. At. Spectrom., 2014,29, 1243-1251

Author version available

Characterization of calcified reference materials for assessing the reliability of manganese determinations in teeth and bone

M. L. Praamsma and P. J. Parsons, J. Anal. At. Spectrom., 2014, 29, 1243 DOI: 10.1039/C4JA00049H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements