Issue 7, 2016

Br isotope determination via the monitoring of CaBr transitions using high-resolution continuum source graphite furnace molecular absorption spectrometry. Potential for direct determination of Br in solid samples using isotope dilution

Abstract

This work investigates the possibility of obtaining Br isotopic information by generating a gaseous diatomic molecule in a graphite furnace and monitoring its absorption spectrum using a high-resolution continuum source device (HR CS GFMAS). Different metals (Al, Ba, and Ca) were investigated to produce this diatomic molecule and the most promising results, both in terms of isotopic shift and sensitivity, were obtained with Ca, thus leaving CaBr as the target species. The results demonstrate that, unlike what occurs when monitoring atomic spectra, which are characterized by very small isotopic shifts that can hardly be detected, using HR CS GFMAS it is feasible to observe several molecular transitions corresponding to Ca79Br and Ca81Br that are spectrally resolved (i.e. they act like two different molecules absorbing at different wavelengths), and can be simultaneously quantified. The method developed relies on the addition of both Pd and Ca (as a chemical modifier and molecule forming agent, respectively), the selection of peak height values and the use of IBC-m (iterative baseline correction for the monitoring of molecules) for setting the baseline. This method enables accurate Br isotopic analysis in 10 mg L−1 solutions with precision values around 2.5% RSD, without requiring any method for mass bias correction. Moreover, it is also demonstrated how the use of isotope dilution for calibration can help in circumventing severe chemical interferences (e.g., deriving from the presence of high amounts of Cl) when aiming at the direct determination of Br in solid samples by HR CS GFMAS. The accuracy of the method was evaluated via analysis of two different reference materials, poly(vinyl chloride) and tomato leaves.

Graphical abstract: Br isotope determination via the monitoring of CaBr transitions using high-resolution continuum source graphite furnace molecular absorption spectrometry. Potential for direct determination of Br in solid samples using isotope dilution

Article information

Article type
Paper
Submitted
22 Март. 2016
Accepted
25 Апр. 2016
First published
26 Апр. 2016

J. Anal. At. Spectrom., 2016,31, 1381-1390

Br isotope determination via the monitoring of CaBr transitions using high-resolution continuum source graphite furnace molecular absorption spectrometry. Potential for direct determination of Br in solid samples using isotope dilution

F. V. Nakadi, M. A. M. S. da Veiga, M. Aramendía, E. García-Ruiz and M. Resano, J. Anal. At. Spectrom., 2016, 31, 1381 DOI: 10.1039/C6JA00114A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements