Issue 10, 2015

Determination of rare earth elements in graphite by solid sampling electrothermal vaporization-inductively coupled plasma mass spectrometry

Abstract

A method is proposed for the determination of trace rare earth elements (REEs) in graphite by solid sampling electrothermal vaporization-inductively coupled mass spectrometry (ETV-ICP-MS). The operating parameters of the ETV system such as gas flow-rate, heating program, the use of a modifier gas (Freon R-12) as well as sample mass were evaluated. The determination of REE in graphite samples was performed by directly weighing a solid sample (0.5 to 2.5 mg) on the graphite platform of the ETV system. Calibration was carried out using aqueous standards. According to the results, the presence of the modifier gas (Freon R-12) promoted an enhancement of vaporization for all analytes, besides the reduction of the vaporization temperature (about 500 °C lower). The accuracy was evaluated by an analyte recovery experiment and also by comparison of results with those obtained by microwave-assisted extraction (MAE) with further determination of REE by ICP-MS equipped with an ultrasonic nebulizer (USN-ICP-MS). Agreement was observed between the results obtained by ETV-ICP-MS and MAE with USN-ICP-MS analysis for most of the elements. Analyte recovery ranged from 100.3 to 118.7% and the obtained RSDs were always lower than 24%. The limits of detection were at the ng g−1 level and were similar to those obtained by USN-ICP-MS with previous sample preparation by MAE. The proposed method was suitable for direct determination of REE in graphite. In addition, direct analysis of graphite by ETV-ICP-MS avoided the laborious sample preparation step of graphite and the use of concentrated acids for digestion, minimizing interferences in the determination step by ICP-MS.

Graphical abstract: Determination of rare earth elements in graphite by solid sampling electrothermal vaporization-inductively coupled plasma mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
10 apr 2015
Accepted
22 mai 2015
First published
11 jun 2015

J. Anal. At. Spectrom., 2015,30, 2048-2055

Determination of rare earth elements in graphite by solid sampling electrothermal vaporization-inductively coupled plasma mass spectrometry

P. A. Mello, M. F. Pedrotti, S. M. Cruz, E. I. Muller, V. L. Dressler and E. M. M. Flores, J. Anal. At. Spectrom., 2015, 30, 2048 DOI: 10.1039/C5JA00136F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements