Fluorescence spectroscopy holds promise as a rapid tracer of performance in decentralized wastewater treatment systems (DEWATS) that may reduce the monitoring burden on communities. In this study, we examined changes in chemical oxygen demand (COD), fluorescence-based indices, and parallel factor analysis (PARAFAC) modeled components under normal operation and during periods of disturbance at the time of scum removal in real decentralized treatment settings and in laboratory simulated wastewater treatment with an anaerobic baffled reactor (ABR). Amino acid-like peaks T and B and PARAFAC component C2 (with excitation/emission peak at 281/335 nm) decreased from influent to effluent due to preferential degradation of labile organic compounds, and the C2 decrease was significantly correlated (p < 0.01) with COD removal. The humification index (HIX) increased by ∼190% on average from influent to effluent during normal operation of all of the anaerobic and aerobic DEWATS evaluated in this study, further supporting the preferential removal of labile constituents during treatment. Meanwhile, a newly identified component, C3, with excitation between 410 and 420 nm and emission at 470 nm, increased under normal operation and may represent the formation of coenzyme 420 during biodegradation. Disturbance during scum removal disrupted preferential removal of peak T and resulted in a much lower change in HIX (only 24% increase) from influent to effluent. Recirculation of effluent into the influent stream was found to greatly reduce scum formation in lab-based ABRs while still maintaining a high removal of COD and peak T and producing substantial increase in HIX. The fluorescence-based indices were found to be robust indicators for tracking performance issues in DEWATS.
Water impactFluorescence indicators, including tryptophan-like and F420-like fluorophores and humification index, tracked degradation of labile organic matter in lab-scale and real world, community-scale anaerobic baffled reactors (ABRs). Recirculation of effluent in ABRs alleviated scum buildup and minimally impacted performance. The establishment of rapidly measured fluorescence indicators can reduce the burden of wastewater monitoring in decentralized systems. |
There is also a motivation to better understand the use of fluorescence spectroscopy as a monitoring tool in decentralized settings. In many decentralized settings, anaerobic treatment systems are preferred because they tend to require low capital costs, low maintenance (compared to centralized, aerobic treatment facilities), low energy, and low sludge generation; although they are not able to achieve nutrient removal without additional polishing or treatment steps. While the use of fluorescence-based metrics for evaluating organic matter removal should be similar in decentralized and centralized wastewater treatment systems, there are both operational (e.g., variable hydraulic loading rates) and process-level (e.g., greater reliance on anaerobic processes) differences that motivate further study into how fluorescence-based metrics track the transformation of organic constituents in decentralized systems. Mladenov et al.5 compared changes in fluorescence peak intensities with COD removal efficiencies in a decentralized system using an anaerobic baffled reactor–anaerobic filter–constructed wetland (ABR–AF–CW) treatment train in South Africa and found that tryptophan-like fluorescence could serve as a surrogate for soluble COD (sCOD). Fluorescence-based sensors could provide early warning of failures or performance issues; however, this has been explored to a lesser extent in community or household scale wastewater treatment systems.
Although the compartmentalized configuration of ABRs makes them more resilient to shock loads, variable flow conditions, and other disturbance,6 the treatment efficiency of anaerobic wastewater treatment systems, including ABRs, can be severely impacted by scum formation,7 which may be monitored using fluorescence-based metrics. Disturbance from the buildup of fats, oils, and grease (FOG) in scum layers was recently shown to negatively impact performance of an ABR–anaerobic filter (AF) system treating domestic wastewater from a community of ∼80 homes in Durban, South Africa (Pietruschka, pers. comm.). In the ABR–AF system in South Africa, scum was observed to accumulate nearly 25 cm in one week, and its buildup necessitated weekly descumming. Manual scum removal, performed by technicians scraping and scooping scum layers, also may represent a disturbance to sludge blanket function in ABR systems. Therefore, alternative strategies for scum removal are needed, and rapid techniques for monitoring the effects of scum formation and removal on ABR system performance are warranted.
To address the aforementioned needs, the goals of this study were to: 1) determine values for fluorescence indices, components, and peak intensities in ABR treatment systems under undisturbed operation and 2) apply fluorescence-based indicators to evaluate the disturbance introduced via scum buildup, manual scum removal, and scum reduction with effluent recirculation. Fluorescence-based metrics and COD removal efficiencies were monitored under conditions of undisturbed operation and disturbance in lab-scale and real world decentralized treatment systems, including an ABR–AF system operating in Durban, South Africa and a lab-scale ABR treating real and synthetic wastewater. For comparison, the performance metrics of an aerobic, decentralized system in Tijuana, Mexico were also considered.
For comparison with the anaerobic treatment provided by the ABR systems described above, samples were collected from the influent (distribution tank) and biotrickling filter effluent of an aerobic decentralized wastewater treatment plant in Tijuana, Mexico. The sampling methods and study site of this facility have been previously described in Garcia et al.11
The synthetic wastewater fed to the ABR during 2016–2017 resulted in noticeable scum buildup (due to high fat and dairy ingredients) over time in each chamber of the lab-scale ABR. Prior to scum and water column sampling, scum layers of between 0.5 cm and ∼3 cm were removed. Then, new scum was allowed to accumulate over a 14 d period, which represented 6 feeding cycles of synthetic wastewater. On days 1, 14, and 28, scum was removed completely from each chamber, dried overnight in a drying oven at 103 deg C, and weighed. On day 42, scum was not removed, and the feed solution was altered to contain 50% synthetic wastewater and 50% recirculated treated effluent. This feeding regime was maintained for the remainder of the experiment. On days 56, 70, and 84 scum was removed completely from each chamber, dried in a drying oven at 103 deg C and weighed. Feed water samples were collected two to three times per week with effluent samples collected 36–48 h later to account for the HRT of the ABR.
Fluorescence-based indices have proven to be robust indicators of dissolved organic matter (DOM) sources and biogeochemical processing. The fluorescence index (FI) was proposed by McKnight et al.13 to distinguish microbial and terrestrial sources of DOM. FI is calculated as the ratio of fluorescence intensities at emission wavelengths of 470 nm and 520 nm and excitation wavelength of 370 nm (as per ref. 14). Lower values of FI (∼1.3 to 1.4) are associated with DOM of terrestrial sources, while higher values (∼1.7 to 1.9) indicate microbially-derived DOM.13 FI values greater than 2.0 typically indicate wastewater-derived DOM.15 The humification index (HIX) was calculated as the ratio of peak area under the emission spectra at 435–480 nm to peak area from 300 to 345 nm obtained at an excitation wavelength of 254 nm, and denotes increased C/H ratios and greater humification of organic matter.16 The freshness index (FrI) was calculated as in ref. 17, and is the ratio of emission intensity at 380 nm divided by the emission intensity maximum observed between 420 and 435 nm, obtained at an excitation of 310 nm. Nomenclature reported for ubiquitous tyrosine-like peak B, tryptophan-like peak T, and humic-like peaks A, C, and M follows18 with peak intensity locations as follows: peak A (260/max(380:460) nm), peak B (275/310 nm), peak T (275/340 nm), peak C (350/max(420:480) nm), peak M (312/max(380:420) nm).
A parallel factor analysis model was performed using 128 corrected, lab-scale ABR and community ABR influent and effluent sample EEMs (94 EEMs from the treatment train of the community ABR in Durban, South Africa and 34 EEMs from the lab-scale ABR treating real and synthetic wastewater). The PARAFAC model was constructed using “drEEM Toolbox” (version 0.2.0)19 with MATLAB R2018a software (The MathWorks Inc.). Outliers were removed, as recommended in ref. 20, and the procedure, including examination of spectral loadings and residual analysis, was run with nonnegativity constraints. A series of models with three to seven components were evaluated (Fig. S3 and S4†), and core consistency analysis gave measurements of 98.5% for a 3-component model, 78.3% for a 4-component model, 66.4% for a 5-component model, 60.8% for a 6-component model, and 3.4% for a 7-component model. The 3-component model was the only one that validated with split-half analysis, and those results are presented here.
Type of wastewater | Treatment type | Year of sampling | N | Percent decrease from influent to effluent of bioreactor | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
COD | FI | FrI | HIX | Peak A | Peak B | Peak T | Peak C | Peak M | ||||
a Values for WW treatment systems during disturbance periods are italicized. | ||||||||||||
Domestic wastewater, South Africa | Community ABR normal operation (no scum issues) | 2015 | 8 | 55 | −6 | 5 | −80 | 39 | 68 | 60 | 9 | 28 |
(12) | (2) | (14) | (27) | (7) | (4) | (6) | (4) | (11) | ||||
Community ABR during scum accumulation | 2017 | 6 | 35 | −2 | −4 | −45 | 14 | 44 | 28 | −2 | 13 | |
(2) | (1) | (1) | (7) | (4) | (5) | (4) | (4) | (6) | ||||
Community ABR after scum removal | 2017 | 6 | 20 | −18 | 33 | −4 | −9 | 11 | 5 | −29 | −18 | |
(20) | (14) | (42) | (42) | (30) | (24) | (25) | (26) | (31) | ||||
“Dairy-like” synthetic wastewater | Lab ABR normal operation w/ scum | 2017 | 10 | 67 | −48 | 22 | −283 | 56 | 92 | 90 | 63 | 61 |
(15) | (26) | (9) | (65) | (5) | (1) | (2) | (4) | (15) | ||||
Lab ABR after scum removal | 2017 | 6 | 64 | −21 | 6 | −44 | 29 | 24 | 49 | 31 | 36 | |
(16) | (21) | (41) | (67) | (51) | (43) | (29) | (50) | (30) | ||||
“Dairy-like” synthetic wastewater | Lab ABR normal operation w/ scum | 2018 | 6 | 75 | −47 | 4 | −359 | 77 | 84 | 83 | 14 | 17 |
(7) | (18) | (9) | (80) | (3) | (4) | (4) | (12) | (19) | ||||
Lab ABR after recirculation | 2018 | 5 | 71 | −34 | 9 | −389 | 75 | 83 | 83 | 5 | 11 | |
(6) | (9) | (6) | (69) | (4) | (5) | (4) | (8) | (11) | ||||
Real, domestic wastewater, USA | Lab ASB | 2018 | 3 | 85 | −3 | −16 | −203 | 47 | 78 | 71 | 8 | 37 |
(93) | (3) | (7) | (92) | (4) | (12) | (13) | (7) | (3) | ||||
Lab ABR | 2018 | 3 | 81 | 1 | −8 | −90 | 53 | 75 | 64 | 28 | 44 | |
(93) | (3) | (3) | (16) | (14) | (5) | (7) | (18) | (15) | ||||
Real, domestic wastewater, Mexico | Bio-trickling filter | 2019–2020 | 5 | 59 | −5 | −2 | −123 | 64 | — | 71 | 48 | 27 |
(2) | (6) | (5) | (37) | (9) | — | (6) | (8) | (15) | ||||
Average of all WW treatment systems under normal operationa | — | 35 | 70 | −18 | 1 | −190 | 56 | 79 | 73 | 28 | 36 | |
(12) | (23) | (13) | (113) | (13) | (9) | (11) | (23) | (15) |
Under lab-scale ABR and community ABR treatment, EEMs contained the ubiquitous peaks B, T, A, M, and C. Tryptophan-like peak T and tyrosine-like peak B were the most pronounced in the influent samples, especially in synthetic wastewater, whereas intensities of humic-like peaks A, C, and M were much lower (Fig. 1a). Even in the real, domestic wastewater influent treated by a lab-scale ABR and community ABR (Fig. 1b and c), peaks A and C had 3 to 10 times lower intensities than peaks B and T.
There are also important changes to note in the fluorescence-based metrics that correspond to the COD treatment efficiencies of different biological treatment systems. Effluent EEMs showed consistent reduction of overall fluorescence, which coincided with decreases in COD concentrations of ∼70% (Table 1). Under normal operating conditions, effluent EEMs also showed substantial decreases in protein-like peaks B and T of 79% and 73%, respectively (Table 1). This large decrease in protein-like fluorescence had been previously reported for the community ABR (Mladenov et al. 2018 (ref. 5)) and attributed to preferential degradation of labile organic compounds along the treatment train. Correlation analysis of all of the treatment types and conditions listed in Table 1, showed that COD removal was correlated with a decrease in all peak fluorescence intensities but most notably with the decrease in peak T and peak B fluorescence (all peak correlations are shown in Fig. S5†), supporting that greater COD removal resulted in preferential degradation of these protein-like peaks.
Our PARAFAC model further explores the changes in dominant fluorescent components from influent to effluent. Three components were identified, with peak maxima at excitation/emission wavelengths (ex/em) of 240(335)/425 nm for C1, 281/335 nm for C2, and 410(242)/470 nm for C3 (Fig. 2). Minor emission peaks in C2 and C3 (with peak areas that were 3.7% and 1.2%, respectively, of the dominant peak) are artifacts, due to Rayleigh scatter features that could not be further excised. C1 has been described in numerous other studies18,22 as representing humic or fulvic acids or humic-like compounds. A similar component in Ishii and Boyer,23 which they called “component 3,” was also associated with humic compounds.
Fig. 2 PARAFAC model results showing EEMs of components 1–3 (C1–C3; top) and two-dimensional profiles of excitation and emission curves for each component (bottom). |
C2 also has been widely reported22 and is associated with amino acid-like fluorescence of tyrosine and tryptophan (peaks B and T, respectively). Yang et al.24 provides a comprehensive review of PARAFAC components encountered in drinking water and wastewater treatment, and noted two common PARAFAC components, tyrosine-like component Ty and tryptophan-like component Try, that were preferentially degraded during biological treatment in multiple studies, compared to more humic-like components, which showed less degradation.
Component C3 in our PARAFAC model has not been reported in previous aquatic DOM or wastewater treatment studies, but seems to be the combination of a low excitation wavelength peak (242 nm) and a higher wavelength peak at 410–420 nm excitation, which may be due to coenzyme 420 (described later), both with emission at ∼470 nm. In our lab-scale ABR samples, C3 increased by 85% on average, while C2 decreased on average by 63%. In our real wastewater samples, the increase in C3 and decrease in C2 were less pronounced (30% increase of C3 and 15% decrease of C2; Table 1), but still notable.
The decrease in COD removal efficiencies was accompanied by changes in fluorescence indices and peak intensities after scum removal in both the community ABR and lab-scale ABR, indicating a disturbance from normal patterns. The main changes were to the HIX and peaks B and T. The HIX slightly increased after manual scum removal (by only 4% and 44% in the community ABR and lab-scale ABR, respectively, or an average of 24% in both systems), compared to the nearly 200% increase under normal operating conditions (Table 1). Peaks B and T, which normally were preferentially removed during wastewater treatment (>70% removal) underwent much lower reductions of 5% to 49% after scum removal (Table 1). Fig. S6† also shows the large decrease in peak T fluorescence that occurred in the community-scale ABR in 2015 and the much smaller change in peak T and the HIX during the scum accumulation and removal conditions in 2017.
Similarly, component C2, representative of peaks B and T, decreased only slightly in the ABR effluent after scum removal, staying at 70% of total fluorescence (or a loading of ∼0.84 RU), compared to 20% of total fluorescence (or a loading of ∼0.20 RU) before scum removal (Fig. 3). The microbially-produced component C3 (similar to co-enzyme F420), which should have increased to >60% in ABR effluent under normal conditions, only increased to ∼ 25% of the total ABR effluent fluorescence after scum removal. C1 was not significantly impacted by scum removal in terms of either loading or % of total fluorescence (Fig. 3).
Changes in pH after recirculation were not significant (pH remained circumneutral), but the influent COD decreased significantly (p < 0.001) after recirculation, from ∼475 mg L−1 to ∼280 mg L−1 (Fig. 4b), due to dilution with recirculated effluent. The COD removal efficiency did decrease slightly under recirculation conditions (from 75% to 71%), but the decrease was not significant (p = 0.081). Also, fluorescence-based performance metrics, such as the humification index and peak A and C fluorescence intensities, did not change significantly (Table 1), indicating that recirculation did not substantially influence these performance metrics. Nevertheless, our calculations (Table S7†) show that the biodegradability of the influent was reduced after effluent recirculation ensued. A simple model, assuming first order exponential degradation of the COD concentrations, gives a decay coefficient of 0.041 h−1 for the 100% synthetic wastewater influent, but only a value of 0.032 h−1 when the treated effluent was mixed 50% with synthetic wastewater (recirculated condition).
In the present study, we show that the same patterns of decreasing tryptophan-like fluorescence and increasing humic fluorescence and HIX also hold for anaerobic treatment systems, such as the lab-scale ABR treating real and synthetic wastewater and the ABR–AF system5 treating domestic wastewater in South Africa in 2015. Indeed, HIX increased by 190% on average for all wastewater treatment systems under normal operation (Table 1). The decentralized, aerobic treatment system in Tijuana, Mexico11 also showed preferential degradation of peak T fluorescence and an increase of HIX by >120%.
PARAFAC components identified in this study, especially components C2 and C3, further demonstrated the preferential degradation of labile organic compounds. Humic-like component C3, which was always higher in ABR effluent than in influent under normal conditions, seemed to be produced when the amino acid-like component, C2, which is similar to peak T, decreased. These changes support the conclusions from peak-picking described above. Also, the reduction of amino acid-like C2 that we observed with biological treatment is in line with what was observed by Cohen et al.2 for their proteinaceous component C1, which was considered to be an indicator of biological treatment efficacy.
Much like the widely used differential absorbance and fluorescence spectroscopy to evaluate performance in water and wastewater treatment processes,4,30 we found that both the directional change (increase or decrease) as well as the magnitude of the differences in the fluorescence-based metrics before and after treatment were important for evaluating the disturbance from scum buildup in the wastewater treatment systems studied here. Results from the community ABR showed that COD removal efficiencies decreased (from 55% ± 12% to between 20 and 30%) during scum buildup and immediately after scum removal (Table 1). This is consistent with the impairment of performance and release of organics into effluent that occurs in a similar technology, upflow anaerobic sludge blanket (UASB) reactors, upon scum accumulation.31
In addition, changes in the fluorescence-based metrics, HIX and peaks B and T, were affected by scum buildup and removal. Increases in the HIX and decreases in peaks B and T, still occurred, but were much smaller than during normal operation (Table 1). Fluorescence spectroscopy was effective in alerting to the impact of disturbance on the ABR treatment system and corroborated that both the buildup and removal of scum represented major disturbances to ABR performance.
Similarly, the synthetic wastewater treated in the lab-scale ABR, with its high fat and lipid content also built up substantial scum layers in each ABR chamber. Although removal of scum from chambers of the lab-scale ABR changed COD removal efficiency only slightly (from 67% removal to 64% removal), the increase of HIX (at only 44% after scum removal) and decreases in amino acid-like peaks B and T (reaching only 24% and 49%, respectively after scum removal) were much lower than before scum removal (at ∼280% increase in HIX and ∼90% decrease of both peaks B and T; Table 1), indicating reduced biodegradation of labile organic compounds in the ABR. Similarly, PARAFAC components C2 (amino acid-like) and C3 (newly produced component) underwent large changes from influent to effluent during normal operation, but exhibited only slight change after scum removal (Fig. 3), further reflecting the disturbance that scum removal produced on effluent quality.
By contrast, recirculation of treated effluent resulted in major dissipation (50–90% mass reduction) of the floating scum mass in each chamber, with no major impacts to ABR performance metrics. It should be noted that the 50% recirculation did decrease the biodegradability of the influent. A back-of-the envelope calculation (Table S6†) shows that the first order degradation coefficient estimated under 100% synthetic wastewater influent (kd = 0.041 h−1) was reduced under the 50% recirculation protocol (kd = 0.032 h−1). Nevertheless, recirculation caused the scum to dissipate and was still able to maintain high COD removal efficiency (at 71%), with only slight shifts in fluorescent peak intensities and HIX compared to those observed under normal operation (Table 2). Therefore, in ABR systems treating wastewater with high lipid content, recirculation of effluent to the influent chamber may alleviate rapid scum buildup without compromising reactor performance. The tradeoffs between pumping costs for recirculation and costs of manual scum removal should be evaluated. However, avoiding treatment system failure or interruption due to scum buildup and manual scum removal is sure to be an important consideration for addressing this ubiquitous maintenance issue.
Constituent | Fresh | 50% recirculated | Comparison of fresh vs. recirculated | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Influent | Effluent | p | N | Influent | Effluent | p | N | Influent | Effluent | |||||
p | p | |||||||||||||
a Bold face indicates significantly different (p < 0.05) values. | ||||||||||||||
pH | 7.76 | ±0.27 | 7.41 | ±0.24 | 0.003 | 7.54 | ±0.32 | 7.48 | ±0.26 | 0.63 | 0.065 | 0.437 | ||
Conductivity (μS cm−1) | 1163 | ±63.0 | 1293 | ±103 | <0.001 | 793 | ±53.0 | 813 | ±58 | 0.31 | <0.001 | <0.001 | ||
COD (mg L−1) | 470 | ±19.7 | 109 | ±27.3 | <0.001 | 287 | ±50.2 | 90.4 | ±30.8 | <0.001 | <0.001 | 0.015 | ||
Fluorescence index | 1.49 | ±0.09 | 2.19 | ±0.21 | <0.001 | 1.63 | ±0.07 | 2.18 | ±0.09 | <0.001 | 0.01 | 0.99 | ||
Freshness index | 1.02 | ±0.10 | 0.97 | ±0.07 | 0.34 | 1.05 | ±0.06 | 0.95 | ±0.03 | 0.01 | 0.44 | 0.71 | ||
Humification index | 0.16 | ±0.02 | 0.72 | ±0.12 | <0.001 | 0.22 | ±0.02 | 1.07 | ±0.07 | <0.001 | <0.001 | <0.001 | ||
Peak A (RU) | 7.49 | ±0.57 | 1.71 | ±0.16 | <0.001 | 3.72 | ±0.44 | 0.93 | ±0.08 | <0.001 | <0.001 | <0.001 | ||
Peak B (RU) | 22.6 | ±1.28 | 3.66 | ±0.75 | <0.001 | 7.98 | ±1.03 | 1.34 | ±0.26 | <0.001 | <0.001 | <0.001 | ||
Peak T (RU) | 26.6 | ±1.76 | 4.56 | ±0.84 | <0.001 | 10.5 | ±1.65 | 1.70 | ±0.18 | <0.001 | <0.001 | <0.001 | ||
Peak C (RU) | 1.14 | ±0.11 | 0.98 | ±0.19 | 0.11 | 0.58 | ±0.06 | 0.54 | ±0.02 | 0.25 | <0.001 | <0.001 | ||
Peak M (RU) | 0 | 1.13 | ±0.13 | 0.03 | 0.70 | ±0.05 | 0.62 | ±0.05 | 0.03 | <0.001 | <0.001 |
In addition, the changes in peak T, HIX and fluorescent components during normal operation and disturbance support previous studies promoting fluorescence-based sensors for wastewater monitoring.5,25 In decentralized settings, where chemical analyses (e.g., COD measurements) may be cost-prohibitive or challenging to complete without staffed laboratory analytical facilities, the tracking of operational issues may be achieved using fluorescence-based sensors monitored remotely or by one technician servicing multiple DEWATS.
Most recently, co-enzyme F420 has been shown to be produced by a much wider suite of organisms than previously thought, including by a number of Archaea besides methanogens,39 some actinomycetes40 and other actinobacter,41 aerobic soil bacteria,42 and even Gram-negative bacteria, such as Paraburkholderia rhizoxinica43 and Escherichia coli.44 Also, our experimental incubations of Pseudomonas syringae with glutamate, a non-fluorescent compound, in a previous study45 resulted in the striking formation of F420-like peaks within 5 d to 12 d of incubation (see representative EEM in Fig. 1d). Our observation of this peak during growth of P. syringae further adds this common Gram-negative bacterium to the list of microorganisms that may produce co-enzyme F420.
In the present study, C3 (the F420-like component) formed in most treated effluents (Fig. 1), after degradation of labile wastewater constituents (represented by reduction of protein-like fluorescence). A shoulder in the region of C3 is often visible in representative EEMs of treated effluent from centralized wastewater treatment plants;4,46 however, PARAFAC models have not yet identified a component reflecting this F420 peak. This may be due to the lower intensity of fluorescence in this region compared to the intensity of other nearby peaks (e.g., humic peak C at ex/em 350 nm/∼450 nm). Our PARAFAC model was able to distinguish C3, likely because there were a substantial number of EEMs from lab-scale ABRs in which C3 was more pronounced. Also, some studies did not measure fluorescence at excitation wavelengths >400 nm (e.g., Yang et al.24), which would preclude identification of this peak. Studies evaluating cyanobacteria and waters with algal blooms have uncovered other algal-associated peaks,47–49 but none of the algal-associated peaks are in the same spectral space as the F420-like peak.
The formation of C3 also may have an important influence on the FI, which is calculated at an excitation wavelength of 370 nm, a wavelength that may be influenced by spectral overlap of fluorescence in the C3 region. The FI of wastewater has generally been found to be higher than FI values reported in environments not influenced by wastewater or fecal pollution,50 and values >2.0 have been used to indicate wastewater contamination in a water body.51 In the present study, the increase in C3 from influent to effluent of the lab-scale ABR corresponded to an increase in the FI from 2.37 to 2.67 on average. The possible influence of C3 spectral overlap on emission at wavelengths where FI is calculated (470 nm and 520 nm) merits further study.
Our results demonstrated that, under normal operation, increases in HIX as high as 190% occurred from influent to effluent, and the HIX was a robust indicator of performance. Peaks T and B and amino acid-like PARAFAC component C2 also decreased under normal operation. Therefore, the HIX, amino acid-like fluorescent peak intensities, and amino acid-like component C2 are valuable surrogates for tracking the preferential degradation of labile organic compounds, and, in turn, for evaluating DEWATS performance. The magnitude of the differences did differ among treatment systems; therefore, no set target values for HIX, peak T, or C2 are recommended here. Instead, expected values can be determined for treatment systems on a case-by-case basis. The establishment of these easily and rapidly measured fluorescence indicators can inform future real-time sensor studies, which is necessary for reducing the burden of decentralized wastewater monitoring for communities.