Tomasz
Chudziak
ab,
Verónica
Montes-García
c,
Włodzimierz
Czepa
ab,
Dawid
Pakulski
b,
Andrzej
Musiał
bd,
Cataldo
Valentini
b,
Michał
Bielejewski
d,
Michela
Carlin
e,
Aurelia
Tubaro
e,
Marco
Pelin
e,
Paolo
Samorì
*c and
Artur
Ciesielski
*bc
aFaculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznańskiego 8, Poznań, Poland
bCenter for Advanced Technologies, Adam Mickiewicz University, Uniwersytetu Poznańskiego 10, Poznań, Poland. E-mail: ciesielski@unistra.fr
cUniversity of Strasbourg CNRS ISIS UMR 7006, 8 Alleé Gaspard Monge, F-67000 Strasbourg, France. E-mail: samori@unistra.fr
dInstitute of Molecular Physics, Polish Academy of Sciences, M. Smoluchowskiego 17, 60-179 Poznań, Poland
eDepartment of Life Sciences, University of Trieste, Via Fleming 22, 34127 Trieste, Italy
First published on 20th October 2023
The presence of oxygen-containing functional groups on the basal plane and at the edges endows graphene oxide (GO) with an insulating nature, which makes it rather unsuitable for electronic applications. Fortunately, the reduction process makes it possible to restore the sp2 conjugation. Among various protocols, chemical reduction is appealing because of its compatibility with large-scale production. Nevertheless, despite the vast number of reported chemical protocols, their comparative assessment has not yet been the subject of an in-depth investigation, rendering the establishment of a structure–performance relationship impossible. We report a systematic study on the chemical reduction of GO by exploring different reducing agents (hydrazine hydrate, sodium borohydride, ascorbic acid (AA), and sodium dithionite) and reaction times (2 or 12 hours) in order to boost the performance of chemically reduced GO (CrGO) in electronics and in electrochemical applications. In this work, we provide evidence that the optimal reduction conditions should vary depending on the chosen application, whether it is for electrical or electrochemical purposes. CrGO exhibiting a good electrical conductivity (>1800 S m−1) can be obtained by using AA (12 hours of reaction), Na2S2O4 and N2H4 (independent of the reaction time). Conversely, CrGO displaying a superior electrochemical performance (specific capacitance of 211 F g−1, and capacitance retention >99.5% after 2000 cycles) can be obtained by using NaBH4 (12 hours of reaction). Finally, the compatibility of the different CrGOs with wearable and flexible electronics is also demonstrated using skin irritation tests. The strategy described represents a significant advancement towards the development of environmentally friendly CrGOs with ad hoc properties for advanced applications in electronics and energy storage.
On the one hand, thermal reduction represents one of the most attractive reduction methods due to its low environmental impact. However, the high temperatures typically required to accomplish this process (above 1000 °C) are energetically demanding and are incompatible with the use of plastic substrates often desired for flexible electronic applications.21 Recently, we have reported a systematic study on the low-temperature annealing of GO by optimizing different annealing conditions, i.e., temperature, time and reduction atmosphere.4 We have demonstrated that TrGO can be obtained under air or inert atmosphere at relatively low temperatures (<300 °C) exhibiting low film resistivities (10−2–10−4 Ωm) combined with unaltered resistance after 2000 bending cycles when supported on plastic substrates. Besides, TrGO electrodes displayed enhanced electrochemical performance, achieving a specific capacitance of 208 F g−1 and a capacitance retention >99% after 2000 charge–discharge cycles.4
On the other hand, chemical reduction is currently the most efficient approach for reducing GO, approaching the electrical characteristics of graphene (8.5 × 104 S m−1 is the highest electrical conductivity reported for CrGO).22 Chemical reduction is appealing from the industrial point of view because of its compatibility with large-scale commercial production with low-energy consumption (temperature of reduction is usually below 100 °C). CrGO can be obtained by using a plethora of reducing agents including hydrazine hydrate (N2H4), dimethylhydrazine, p-phenylene diamine, ethylenediamine, hydroxylamine,23,24 lithium aluminium hydride, sodium borohydride (NaBH4),25 sodium bisulfite (NaHSO3), L-ascorbic acid (AA),26–28 or sodium dithionite (Na2S2O4), among others.
However, a variety of reducing agents and protocols have been reported in the literature (Table S2, ESI†), making it quite difficult to assess and compare these strategies from the perspective of structure–performance relationship. For instance, for applications in electronics, CrGO with the highest electrical conductivity is desirable and therefore the removal of OFGs should be maximized. Unfortunately, some of the employed reducing agents or their oxidized forms may also result in doping or contamination of the CrGO. Although CrGO synthesized with hydrazine hydrate is usually considered to most closely resemble pristine graphene in terms of electronic and structural properties, it has been reported that films of CrGO synthesized using sodium borohydride have significantly lower sheet resistance. This result can be explained by CrGO contamination with nitrogen and pyrazole formation, where the nitrogen atoms behave as electron donors and supply p-type holes.25,29,30 Ascorbic acid, which can be regarded as the most studied ‘green’ reducing agent to obtain CrGO, also suffers from the same contamination problem.26,28,31–33 AA is oxidized first to dehydroascorbic acid (DHA) and then to oxalic and guluronic acids, both of which can supramolecularly interact with the unreacted carboxylic groups of pristine GO.34–36
In contrast to electrical applications, the scenario is not as straightforward when it comes to electrochemical energy storage applications.37,38 As previously reported, OFGs contribute towards enhancing the electrochemical performance of pseudocapacitive rGO electrodes and their removal is always detrimental to the device performance. For instance, ultrahigh-level oxygen-functionalized GO (UHFGO) has shown an impressive capacitance of 285 F g−1 in a gel electrolyte.39 Alternative strategies such as heteroatom doping have also been widely employed to boost the electrochemical performance of pristine GO.40,41 Nevertheless, the electrochemical performance of rGO electrodes is superior to that of pristine GO electrodes because the removal of OFGs is accompanied by other physicochemical and structural changes in rGO, such as an increase in conductivity, surface area and pore size. Therefore, the best reducing conditions for applications in electronics or in electrochemical energy storage may differ. To the best of our knowledge, there is no systematic study that compares the physicochemical and structural properties of CrGO with its performance in electronics or in electrochemical energy storage by using different reducing agents and reducing times. Furthermore, one of the major criticisms that chemical reduction has received is the use of toxic reducing agents. However, there has been limited discussion regarding the toxicity of the resulting CrGO.
To address this significant knowledge gap, we investigated the fine-tuning of the reduction degree of GO by varying the reduction conditions, specifically the choice of the reducing agent and reaction time (2 or 12 hours). Regarding reducing agents, we focused our attention on four of the most commonly employed ones, namely, hydrazine hydrate, sodium borohydride, ascorbic acid, and a sulphur-containing compound such as sodium dithionite.42,43 Our study was aimed at systematically investigating how these factors influenced the toxicity and the physicochemical and structural properties of CrGO, ultimately boosting their performance for electronic devices or energy storage applications.
The degree of GO reduction is usually expressed by the C/O ratio obtained from X-ray photoelectron spectroscopy (XPS) analysis. However, as XPS is a surface-sensitive technique (i.e., the penetration depth of the XPS beam ranges only between 1 and 10 nm), we firstly performed elemental analyses (E.A.) of chemically reduced GO (Table S3, ESI†). As can be seen in Table S3,† the C/O ratio ranges from 0.99 for pristine GO to 7.20 for rGO(N2H4)_12 h. According to the C/O ratio, the strength of the reducing agents varies as follows: Na2S2O4 ≈ N2H4 > AA > NaBH4, in agreement with FTIR analyses. Interestingly, the nitrogen content is slightly higher in the samples reduced with N2H4, indicating a possible contamination from the reaction of GO with N2H4 (e.g., pyrazole formation).
To gain insights into the chemical composition of CrGO, X-ray photoelectron spectroscopy (XPS) and solid-state NMR magic angle spinning (ssNMR-MAS) analyses were then performed on the GO and CrGO powders (Fig. 1–2 and Fig. S2–10, ESI†). From the XPS survey spectra (Fig. S2 and 3, ESI†), the C/O ratio was estimated (Table S4, ESI†), ranging from 0.86 for pristine GO up to 11.21 for rGO(Na2S2O4)_12 h. In full agreement with FTIR and E.A., the strength of the reducing agents followed the same trend. Likewise, the nitrogen element was also present in the rGO(N2H4) samples, and its amount was proportional to the reaction time (2.70% after 12 hours of reaction). Traces of sodium element (∼1%) were found in the rGO(NaBH4) samples, but were not sufficient to be detected in elemental analysis. No contamination of sodium or sulfur was observed in the rGO(Na2S2O4) samples. Regarding the reaction time, a negligible difference (i.e., max. 5% of increase) was obtained between 2 and 12 hours of reaction for all the reducing agents. Although FTIR, E.A. and XPS survey spectra showed the same tendency in the strength of the reducing agents, a deeper analysis was needed to unveil the influence of the reaction time. To cast light onto the chemistry of the reduction process by each reducing agent, the high resolution C 1s and O 1s XPS and ssNMR-MAS spectra were deconvoluted as previously reported by us.4 The high resolution C 1s spectra were fitted using 5 Gaussian–Lorentzian curves for the 5 chemical environments: 284.5 eV C–C (Csp2–Csp2), 285.15 eV C–O (including Csp2–O–Csp2, Csp3–OH and Csp2–OH), 286.5 eV C–O–C (Csp3–O–Csp3), 287.40 eV CO, and 288.50 eV COOR (including COOH and lactone) (Fig. 1(a), (d) and Fig. S4, ESI†).4 Likewise, the high resolution O 1s spectra were fitted with 3 Gaussian–Lorentzian curves: 531.08 eV CO, 532.03 eV Csp3–O (including Csp3–O–Csp3, and Csp3–OH), and 533.43 eV Csp2–O (including Csp2–O–Csp2 and Csp2–OH) (Fig. 1(b), (e) and Fig. S5, ESI†).4 To complete the analysis, the ssNMR-MAS spectra were deconvoluted in eight curves: 60.4 ppm (13Csp3–O–13Csp3), 70.6 ppm (13Csp3–OH), 78.9 ppm (13Csp3–OH, close to defects), 100.2 ppm (13C–OOR), 126.7 ppm (13Csp2–13Csp2), 134.7 ppm (13Csp2–13Csp2 close to defects), 162.4 ppm (Csp2–O (including Csp2–O–Csp2 and Csp2–OH)) and 187.9 ppm (13CO) (Fig. 1(c), (f) and Fig. S8, ESI†). Fig. 1 shows the deconvolution of the C 1s and O 1s XPS and ssNMR-MAS spectra for GO (Fig. 1(a–c)) and as representative CrGO, we show analogous results using rGO(N2H4)_12 h (Fig. 1(d–f)). The results for all the reducing agents and reaction times can be seen in the ESI (Fig. S4–5 and S8†).
Fig. S7 and S9 (ESI†) show the evolution of the area of each component in XPS (Fig. S7, ESI†) and ssNMR spectra (Fig. S9, ESI†) as a function of the reducing agents and reaction time. However, for a straightforward analysis, we divided the components into three groups, (i) CC (Fig. S10, ESI†), (ii) CO (Fig. 2(a–c)) and (iii) C–O (Fig. 2(d–f)). As expected, the area of the CC (Fig. S10(a), ESI†) and Csp2–Csp2 (Fig. S10(b), ESI†) peaks increased in all the cases as the reduction process restored the π-conjugation of the carbon sheets. While the largest CC and Csp2–Csp2 peak areas were obtained for rGO(Na2S2O4)_2 h, the smallest CC and Csp2–Csp2 peak areas were observed for rGO(NaBH4)_2 h. The reaction time only played a major role when NaBH4 was used as a reducing agent. The area of Csp2–Csp2 close to the defects (Csp2–Csp2*) increased with the reduction process. Interestingly, we observed a decrease of the Csp2–Csp2* peak area after 12 hours of reaction when NaBH4 and N2H4 were used. This can be directly correlated with the contamination with the sodium and nitrogen elements, respectively, which reacted with the defects present in the GO sheets. To demonstrate the reactivity between GO and N2H4, the high-resolution N 1s XPS spectra were obtained (Fig. S6, ESI†) at 2 and 12 hours of reaction. Fig. S6 (ESI†) shows the formation of a pyridine ring, C–N–C and a pyrrole or diazine ring (N–CO).45,46 Among the different OFGs present in GO, carbonyl groups, either in the form of CO or COOR, were present in the lowest percentage. Fig. 2(a–c) shows that N2H4 is the most efficient reducing agent for the COOR groups, whereas all reducing agents yielded similar amounts of CO moieties. The evolution of the area corresponding to the four different C–O species present in GO can be seen in Fig. 2(d and f). The peak area of C–O–C or 13Csp3–O–13Csp3 (Fig. 2(d) and (f), respectively) decreased after chemical reduction and no major differences were found between all the reducing agents or the reaction times. The same trend was observed for Csp3–O peaks (which include both the Csp3–O–Csp3 and Csp3–OH peaks) (Fig. 2(e)) but Na2S2O4 showed a higher decrease (nearly 30% compared to GO). Finally, the most interesting findings were revealed by the Csp2–O species (which included both Csp2–O–Csp2 and Csp2–OH). As we previously demonstrated, during the reduction process there was a structural reorganization of Csp3–O to Csp2–O and therefore we observed an increase in the peak area of the Csp2–O species. However, when the reduction continued, the OFGs were eliminated, leading to a decrease in the peak area of the Csp2–O species. This phenomenon can be clearly observed by ssNMR (Fig. 2(f)). For the mildest reducing agent rGO(NaBH4)_2 h, there was a sharp increase of the Csp2–O peak area compared to that of pristine GO, which then decreased when the reduction was performed for 12 hours. The same trend was observed when rGO(AA)_2 h, the following reducing agent by strength, was used. However, the peak area increase was lower than that in rGO(NaBH4)_2 h and when the reduction was performed for 12 hours the peak area of Csp2–O was comparable to that of pristine GO. Interestingly, when N2H4 was used, no increase in the peak area of Csp2–O was observed, independent of the reaction time. Finally, rGO(Na2S2O4)_2 h followed the same trend as rGO(AA) but with a lower peak area increase. Therefore, ssNMR unequivocally proves that the strength of the reducing agents varies as follows: Na2S2O4 ≈ N2H4 > AA > NaBH4. Besides, the reaction time plays a role for three of the reducing agents, Na2S2O4, AA and NaBH4.
Raman spectroscopy confirmed not only the chemical composition of CrGO but also that the different Raman features (e.g., band position, intensity ratio and width) were related to structural parameters such as crystallinity, reduction degree of GO and oxygen content.47 The Raman spectra of GO and CrGO were deconvoluted by using five Lorentzian curves, which consist of the first-order Raman modes, namely: D, D′′, D′, D* and G (Fig. S11 and 12, ESI†). While the D band (∼1350 cm−1) is associated with the breathing modes of photons of A1g symmetry, the G band (∼1585 cm−1) is related to the first-order scattering of E2g phonons of the sp2 carbon structure.48 Commonly, the relative intensity of the D band with respect to the G band (ID/IG ratio) is an insightful parameter to estimate the degree of defects in GO derivatives and it has been correlated with the inverse of the crystallite size on basal planes (1/La) by Tuinstra and Koenig.49 Fig. S13(a) (ESI†) reveals that the ID/IG ratio increases for all the reducing agents, indicating the restoration of sp2 conjugation due to the removal of the oxygen functional groups from GO.50,51 The increase in the ID/IG ratio is proportional to the strength of the reducing agent, in full agreement with previous characterization results. In addition, the ID/IG ratio decreases after 12 hours of reaction when AA and N2H4 are employed, which is related to undesired contamination. The additional bands (D′′, D* and D′) arise from the defects present in the graphitic structure of the carbon material.48,52–54 The ID′′/IG, ID*/IG, and ID′/IG ratios are shown in Fig. S13(b), (c) and (d) (ESI†), respectively. Ideally, all these ratios should decrease with the reduction degree but as we can see, the ID′/IG and ID*/IG ratios increased slightly in all the cases; therefore, it can be concluded that the chemical reduction process creates defects in the graphitic structure of the carbon material. In contrast, the ID′′/IG ratio decreases in all the cases and the decrease is proportional to the strength of the reducing agent.
To unravel the number of defects present in the pristine GO and CrGO we followed the protocol reported by Cançado et al.51 First, we calculated the average defect distance (LD) by using eqn (2) (see the Materials and characterization section in the ESI† for details). As shown in Fig. S14(a),† the LD of pristine GO amounts to 9.64 ± 1.11, which upon reduction only decreases slightly to 8.27 ± 0.95 for the strongest reducing conditions (rGO(Na2S2O4)_12 h). As LD ≈ 10, we estimated the number of defects in each case by using eqn (3) (see the Materials and characterization section in the ESI† for details). Fig. S14(b)† shows that the number of defects in GO and CrGO is between 7.8 × 1010 and 10.6 × 1010.
The effect of the different reducing agents on the crystallinity of CrGO was investigated using powder X ray diffraction (PXRD) (Fig. 3). The pristine GO diffraction pattern displays one characteristic peak at 2θ = ∼10° (peak I) with a Full-Width at Half Maximum (FWHM) of 0.81 related to the (002) family of planes (Fig. 3). After the chemical reduction, the CrGO exhibits one characteristic peak at 2θ = ∼25° (peak II), with a larger FWHM of 4.4–5.81°, related to the smaller crystallite sizes and a second at about 42.8° related to the (100) family of planes. Fig. 3 shows that after two hours of reaction peak I completely disappears when Na2S2O4, N2H4 and AA reducing agents are used. However, peak I is still present even after 12 hours of reaction when NaBH4 is used, which is in agreement with the results obtained by Shin et al.25 From the scattering angle (2θ) of each peak we can quantify the d-spacing, average crystalline size (La), crystalline thickness (Lc), and graphene layer number (n) for GO and all CrGO using the Debye–Scherrer equation (Fig. 3(c) and Table S5, ESI†). The d-spacing of pristine GO amounts to 8.79 Å and after its chemical reduction, it decreased to ∼3.76 Å.55,56 The considerable shrinkage of the interlayer distance is connected to the partial removal of the OFGs from the GO sheets. The d-spacing slightly decreases with the reaction time but no major differences are found between the reducing agents employed. The crystal thickness (Lc) considerably decreases from 97.32 Å of pristine GO to ∼15.5 Å after its chemical reduction. Interestingly, no major differences are found between the reducing agents and reaction time for both Lc and La (Fig. 3(c) and Table S5, ESI†). Remarkably, the theoretical number of layers (nc) reveals that few layer-thick CrGO sheets (3–5 layers) can be produced even with mild reducing agents like AA. Therefore, we can conclude that the choice of the reducing agent and reaction time have no strong influence on the crystallinity of the resulting CrGO.
Fig. 3 XRD patterns of rGO reduced for (a) 2 hours and (b) 12 hours, and (c) dependence on crystal size (La) and d -spacing in correlation with the reducing agent. |
Scanning electron microscopy (SEM) images (Fig. S15 and 16, ESI†) reveal the absence of morphological changes upon the chemical reduction of GO for all the reducing agents and reaction times employed. Thermogravimetric analysis (TGA) was then performed to evaluate the thermal stability of CrGO (Fig. S17, ESI†). As shown in Fig. S17 (ESI†), the thermal stability of GO increased upon chemical reduction and the Td10 (thermal decomposition of 10% weight) increased from 70 °C (pristine GO) to 430 °C in the case of Na2S2O4 and N2H4 and to 450 °C in the case of AA and NaBH4. Two main conclusions can be drawn from the TGA analysis: in agreement with the previous characterization results, no major differences were found between the two reaction times studied and the thermal stability of CrGO was the highest for the samples with the highest C/O ratio and therefore characterized by a greater Csp2 content.
The specific surface area and average pore size of CrGO were evaluated by recording N2 adsorption–desorption isotherms at 77 K (Fig. S18–21, ESI†). The adsorption isotherms of the CrGO exhibited type-I sorption isotherms, with steep rises appearing at low relative pressure and type-IV sorption features with adsorption/desorption hysteresis at higher pressure. The calculated Brunauer–Emmett–Teller (BET) surface area of CrGO revealed significant differences between the reducing agents used (Fig. S22(a), ESI†). In all the cases, the surface area increased with the reaction time (between 25 and 97% increase). Interestingly, the two reducing agents that produced CrGO with the highest C/O ratio (Na2S2O4 and N2H4), exhibited the lowest surface areas (140.91 and 96.41 m2 g−1, respectively, after 2 hours of reaction). In contrast, when the mildest reducing agents AA and NaBH4 were used, CrGO exhibited the highest surface areas (394.90 and 555.63 m2 g−1, respectively, after 12 hours of reaction) compared to pristine GO (12.61 m2 g−1). The same trends were observed for the average pore size of CrGO (Fig. S22(b), ESI†), ranging from 1.40 nm when Na2S2O4 was used for 2 hours of reaction time, to 13.70 nm when AA was used for 12 hours of reaction time.
To gain a greater insight into the electrical performance of CrGO, thin film conductivity measurements were performed. Pellets of different materials were prepared (see the ESI†) and the film resistivity was measured with a four-point probe (FPP) (Fig. S23, ESI†). Due to its insulating character, the film resistivity of the pristine GO material was above our instrument's detection limit. The film conductivity of CrGO, ranging from 2.7 × 101 S m−1 (rGO(NaBH4)_2 h) to 4.3 × 103 S m−1 (rGO(Na2S2O4)_2 h), gradually increased with the strength of the employed reducing agent, following a trend in full agreement with the previous characterization results. Therefore, for electrical applications, rGO(AA)_12 h, rGO(Na2S2O4) and rGO(N2H4) represent the best choices, as their performance is comparable.
To explore the compatibility of our reduction process with substrates employed in flexible electronics, the reduction of a film GO deposited on polyethylene terephthalate (PET) is performed using the four reducing agents. As can be seen in Fig. S24 (ESI†), only the CrGO films reduced with AA and Na2S2O4 are stable and homogeneous. Then, the mechanical stability of the films was tested by performing 2000 bending cycles (Fig. S25, ESI†). The resistance of the film was constant for the 2000 bending cycles performed with subtle variations below 1%.
The pseudocapacitive behavior of CrGO is confirmed by galvanostatic charge/discharge curves, as shown in Fig. 4(b), (e) and Fig. S27 (ESI†). The voltage–time curve exhibits a quasi-linear shape and similar trends to those obtained by CV analysis. The specific capacitances of CrGO were calculated from GCD profiles at different current densities, as shown in Fig. S28 (ESI†) (see the Materials and characterization section, Experimental details subsection for calculation details). The maximum specific capacitance amounts to 211 F g−1 for rGO(NaBH4)_12 h. From these values two main conclusions can be drawn: (i) the reaction time plays a major role in the obtained specific capacitance of CrGO for the four reducing agents and (ii) the obtained specific capacitances of CrGO are not directly proportional to the strength of the reducing agents employed.
Surface area, porosity, electrical and ionic conductivity and electrochemical activity have been identified as the key properties that strongly influence the electrochemical performance of materials employed as energy storage systems (ESS). The increase in surface area is directly proportional to the electrochemical performance, as a large surface area offers access to abundant active sites for electrochemical reactions or electrostatic interactions.59 As shown in Fig. S29(a) (ESI†), surface area and capacitance follow nearly the same trend for the different reducing agents and reaction times. High porosity is crucial in faradaic charge transfer processes in pseudocapacitive-type materials and determines the access of the charge transfer active sites and facilitates ion conduction through the electrode material.60 As in the case of surface area, Fig. S29(b) (ESI†) shows that pore size and capacitance follow the same trend. Higher electrical conductivity facilitates electron migration from electrode materials to current collectors, enabling better rate performance. Fig. S29(c) (ESI†) shows that above a certain threshold (conductivity > 20 S m−1) the increase in electrical conductivity is not translated into an increase in capacitance. Ionic conductivity is a critical factor affecting the electrochemical performance of double-layer capacitors and pseudocapacitors. Improved ionic conductivity helps instantaneous polarization across the electrode surface, which permits greater access of the electrolyte ions within a short time. The ionic conductivity of GO and CrGO-based electrodes is obtained using electrochemical impedance spectroscopy (EIS) (see Table S6, ESI†). Fig. S29(d) (ESI†) shows that, except for GO, the ionic conductivity and capacitance follow the same trend. The presence of electrochemically active groups (e.g., OFGs) is advantageous, as they can provide a large additional pseudocapacitance. During the reduction process, OFGs are eliminated and therefore this is detrimental to the electrochemical performance. Fig. S29(e) (ESI†) shows that the two reducing agents that produce CrGO with lower oxygen content (i.e., N2H4 and Na2S2O4) also show the lowest capacitance values. In contrast, AA and NaBH4 produce CrGO with higher oxygen content, but only after 12 hours is the specific capacitance boosted. Pristine GO, despite having the highest amount of OFG, exhibits the lowest capacitance due to its small surface area and poor conductivity.
All CrGO samples show a good rate capability, with a decrease of less than 30% in capacitance at higher current densities. For instance, the capacitance of rGO(NaBH4)_12 h is as high as 169 F g−1 at a high current density of 20 A g−1, implying a quick charge propagation. Another important factor affecting the electrochemical performance of supercapacitor devices is the Ohmic drop (IR), which is caused by internal resistance (including the electrolyte resistance, the resistance of the electrode active-material, and the contact resistance between the active materials and the current collector).61,62 In the case of the rGO(NaBH4), rGO(AA), and rGO(Na2S2O4) electrodes, we can observe a very small IR drop (∼2–3%) while the rGO(N2H4) electrodes exhibit a significantly larger IR drop (∼20%), which indicates a non-effective discharging process.
Moreover, the EIS data are evaluated by examining the Nyquist plots (shown in Fig. 4(c) and (f)). In an ideal double-layer capacitor, the Nyquist plot should appear as a vertical line running parallel to the imaginary axis. However, the presence of a semicircle at high frequencies indicates the existence of various OFGs on the GO surface, giving rise to a pseudocapacitive behavior. The experimental results are well-fitted with the indicated circuit (Fig. S30, ESI†) and the fitting parameters can be seen in Table S6 (ESI†). The low Rct values of CrGO are consistent with the fact that at a current density, as high as 20 A g−1, a high value of capacitance is still obtained, indicating a good rate capability of the CrGO samples. Besides, among the different CrGO samples, rGO(N2H4)_12 h shows the highest Rct, which is in agreement with the observed largest IR drop.
The long-term stability of the prepared CrGO electrodes was then investigated using galvanostatic charge–discharge cycles at a current density of 1 A g−1 (Fig. S31, ESI†). The samples exhibited excellent long-term stability Independent of the reducing agent and reaction time. For instance, CrGO at 12 hours of reaction time exhibited retention rates of 99.5%, 97.5%, 97% and 95% of the initial capacitance for rGO(NaBH4), rGO(AA), rGO(Na2S2O4), rGO(N2H4), respectively, after 2000 cycles.
The energy and power density of CrGOs are plotted in Fig. S32 (ESI†), with: (1) the highest energy density of 29.3 W h kg−1 and (2) the highest power density of 10 kW kg−1 achieved for rGO(NaBH4)_12 h. The energy density is directly proportional to both the specific capacitance and the voltage window. Since the voltage window remains constant in all cases, the efficiency of the various reducing agents and reaction times correlates with the obtained capacitance in a similar trend. The energy and power density values mentioned are highly suitable for applications related to energy storage.63 Furthermore, it has been observed that the wettability, which is closely linked to the quantity of OFGs on the surface of rGO samples, plays a significant role in energy storage applications.64 Improved wettability enhances the effective energy density, as demonstrated in Table S4 and Fig. S33 (ESI†), where the rGO(NaBH4) sample, with the highest oxygen content, exhibits both the best wettability and the highest energy density. Surprisingly, the rGO(N2H4) samples, despite having a lower oxygen content than rGO(AA)_12 h, are more hydrophilic, probably due to the presence of nitrogen heteroatoms. The higher hydrophilicity of the rGO(N2H4) and rGO(NaBH4) samples is also in full agreement with the lower stability of CrGO films deposited on PET substrates.
Our investigations using E.A. and XPS revealed that the utilization of N2H4 during the GO reduction process resulted in nitrogen contamination and pyrazole formation. Similarly, NaBH4 led to sodium contamination, while AA induced a supramolecular interaction with DHA within the CrGO structure.
Notably, we demonstrated that CrGO with excellent electrical conductivity (>1800 S m−1) can be synthesized using AA (with a 12 hour reaction time), Na2S2O4, or N2H4 (regardless of reaction time). CrGO produced with AA or N2H4, exhibiting reduced hydrophilicity, enabled the fabrication of films on flexible plastic substrates, maintaining resistance even after enduring 2000 bending cycles.
CrGO synthesized with NaBH4 in a 12 hour reaction exhibited superior electrochemical performance, boasting a specific capacitance of 211 F g−1 at a current density of 0.5 A g−1 and a capacitance retention exceeding 99.5% after 2000 cycles, surpassing the other reducing agents. While the loss of OFGs detrimentally affected electrochemical performance, this drawback was mitigated by a significant increase in surface area, pore size, and ionic conductivity, yielding values of ∼555.63 m2 g−1, 9.60 nm, and 1.04 S m−1, respectively.
Furthermore, skin irritation tests demonstrated that all variants of CrGO could be considered non-irritating materials, affirming that the reduction process does not compromise their biocompatibility at the cutaneous level. These findings represent a significant advancement in the application of reduced graphene oxide (rGO), particularly in wearable and flexible electronics with skin-level interactions.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3nr04521h |
This journal is © The Royal Society of Chemistry 2023 |