Bardiya
Valizadeh
,
Tu N.
Nguyen‡
,
Stavroula
Kampouri
,
Daniel T.
Sun
,
Mounir D.
Mensi
,
Kyriakos
Stylianou
,
Berend
Smit
and
Wendy L.
Queen
*
Institut des Sciences et Ingénierie Chimiques, Valais, Ecole Polytechnique Fédérale de Lausanne (EPFL), Rue de l'Industrie 17, CH-1951 Sion, Switzerland. E-mail: wendy.queen@epfl.ch
First published on 6th May 2020
Herein, a novel integrated adsorption–photoreduction system, which captures highly mobile and toxic hexavalent chromium (Cr(VI)) from real-world water samples and reduces it to less mobile and benign Cr(III) species, was designed. To do this, a known Zr-MOF, UiO-66, was functionalized with double amino groups. This modification permits the new material, Zr-BDC-(NH2)2, to play a dual-purpose as both adsorbent and photocatalyst. Next, Zr-BDC-(NH2)2 was incorporated into MOF@polymer beads (M@PB) using polyethersulfone (PES) that was chemically modified with carboxylic acid groups to improve hydrophilicity. The modification enhances the Cr(VI) extraction rate of the beads by a factor of ∼3 when compared to the unmodified counterpart. In addition, Zr-BDC-(NH2)2@PB offers one of the highest Cr(VI) uptake capacities reported to date, rapid extraction rates, high selectivity for Cr(VI) in real-world water samples, and full recyclability. The adsorption and subsequent regeneration cycles are carried out in a glass column equipped with a visible light source, demonstrating that the Cr(VI) concentration is brought below drinkable levels, and the Cr(VI) subsequently photoreduced to Cr(III) species using light irradiation during adsorbent regeneration. To the best of our knowledge, this is the first demonstration of MOF-based adsorption–photoreduction of Cr(VI) in a single process.
To date, the main methods for Cr(VI) removal from water are chemical precipitation or chemical/photoreduction.9 Both methods are less effective at low concentrations, and chemical precipitation, although simple and inexpensive, produces large amounts of sludge and solid waste.10,11 Chemical- or photoreduction often results in high concentration of Cr(III) in water streams, and, as such, demands a secondary treatment method to reduce concentrations below what is deemed acceptable by the EPA or WHO.12 Therefore, an active area of research is to replace these conventional technologies by solid adsorption, in which the aim is to identify selective materials that are highly effective at low concentrations.13
Some adsorbent-based technologies have already been developed for Cr removal. Most of these technologies use low-cost bio-waste adsorbents and ion-exchange resins. The solid waste from several agricultural or industrial processes, such as chitosan and coconut shells, can be used for Cr capture.14 Although cost-effective, they are sensitive to operating conditions, such as pH, and typically offer low adsorption capacity and selectivity.15 Commercially available resins, such as layered double hydroxides and amino-containing organic resins, are relatively expensive and suffer from poor recyclability and thermal and chemical stability.13 These limitations, drive scientific efforts aimed at the design of new adsorbent technologies. One highly active area of research is in the field of metal–organic frameworks (MOFs), a class of materials which offer permanent porosity, a large number of highly diverse structure types, and unmatched chemical tunability.16,17 Several recent reports demonstrate that MOFs can have superior capacity and selectivity for Cr(VI) in aqueous solutions than the aforementioned adsorbents.18–20 However, the state of the art MOF-based adsorption systems often create highly toxic Cr(VI) waste that is still complicated to treat and dispose.
It is thought that an ideal process involves a combination of adsorption and reduction. The adsorption is required to reduce Cr concentration in the effluent below drinkable limits and the reduction enables the conversion of Cr(VI) into Cr(III), resulting in much less toxic waste after adsorbent regeneration. Although there are some polyaniline-based composite adsorbents that can chemically reduce Cr(VI),21,22 in this work, we develop a process that is based on a MOF that simultaneously and selectively adsorbs chromium ions and photo-reduces the toxic Cr(VI) into the less harmful Cr(III). We show that this MOF can be incorporated into MOF@polymer composite beads, which has one of the highest capacities for Cr(VI) reported to date. In addition, using an adsorption–photoreduction column, we show that our system not only reduces Cr(VI) to below drinkable concentrations, but also reduces it to the less toxic and less mobile Cr(III). As such, there is no need for any treatment upon adsorbent regeneration and chromium release.
The details of the synthesis and characterization of UiO-66 containing ligands functionalized with two amine groups (hereafter referred to as Zr-BDC-(NH2)2) are described in the ESI.† While Zr-BDC-(NH2)2 has the same cubic crystal structure as UiO-66 (space group Fmm, a-axis 20.8112(3) Å, Fig. S1†), the additional NH2 functionality increases the Cr(VI) adsorption capacity by approximately 10% compared to its mono-aminated counterpart (see Table 1). It is thought that this additional functionality increases the number of adsorption sites but decreases the available pore volume from 0.65–0.7 to 0.2 cm2 g−1 for UiO-66 (ref. 33 and 34) and Zr-BDC-(NH2)2, respectively; the net result is only a slight increase of capacity. A more significant effect is observed for the light adsorption. The UV-vis absorbance spectrum of Zr-BDC-(NH2)2 demonstrates a significant red shift compared to the mono-aminated UiO-66 and a much broader absorption over the visible range (Fig. S2†).
Sorbent | Capacity (mg g−1 adsorbent) | Equilibrium time | Recyclability (% in # cycles) | Ref. | ||
---|---|---|---|---|---|---|
Cr(VI) | CrO42− | Cr2O72− | ||||
a Calculated from reported value. | ||||||
UiO-66-NH2@silica | 133.4 | — | 277.4 | 30 min | 8 cycles | 24 |
UiO-66-NH2@algenic acid (MOR-1-HA) | 135a | — | 280 | 9 min | 5 cycles | 19 |
UiO-66-NH2 (MOR-1) | 119a | 247 | >10 min | — | 30 | |
UiO-66 | 62a | 129 | — | — | 30 | |
Zn0.5Co0.5-SLUG-35 | 30.7a | 68.5 | — | 4 h | — | 37 |
BUT-39 | 104a | — | 215 | 1 min | 90% in 3 cycles | 23 |
JLU-MOF60 | 72a | — | 149 | 10 min | 4 cycles | 25 |
SLUG-21 | 26.9a | 60.1 | — | 48 h | — | 38 |
1-ClO4 | 28.2 | 62.9 | — | 6 h | — | 39 |
FIR-53 | 35.7a | — | 74.2 | 4 h | 87% in 5 cycles | 40 |
FIR-54 | 49.6a | — | 103 | — | 63% in 5 cycles | 40 |
ABT·2ClO4 | 103a | — | — | 24 h | NA | 41 |
MONT-1 | 102a | — | 211.8 | 24 h | 73% in 5 cycles | 42 |
2D-Ag-3 | 80a | — | — | 24 h | NA | 43 |
ZJU-101 | 118a | — | 245 | — | NA | 18 |
1-SO4 | 80a | — | 166 | 72 h | — | 44 |
Zr-BDC-(NH 2 ) 2 | 146 | — | 303 | 16 min | 5 cycles | This work |
Zr-BDC-(NH 2 ) 2 @PB | 208 | — | 432 | 35 min | 5 cycles | This work |
Zr-BDC-(NH2)2@PBs were synthesized with 80 wt% loading of Zr-BDC-(NH2)2 and modified PES blend. The powder X-ray diffraction (PXRD) patterns show that Zr-BDC-(NH2)2 crystals remain intact (Fig. S1†). Moreover, energy-dispersive X-ray spectroscopy (EDX) shows a homogeneous loading of the MOF in the polymer matrix (Fig. 3). From a practical point of view, it is important that the polymer matrix does not prevent the adsorption of guest molecules by blocking the pore entrance and/or filling the pores. The BET surface areas, which were calculated from N2 isotherms at 77 K, are 402 and 372 m2 g−1 for Zr-BDC-(NH2)2 and Zr-BDC-(NH2)2@PB, respectively (Fig. S3†). A typical value of the BET for the neat polymer beads is 12 m2 g−1, hence if we assume no polymer–MOF interference we would expect a BET of 402 × 0.8 + 12 × 0.2 = 324 m2 g−1. The fact that the composite beads have a higher BET surface area indicates that there is some synergy between the MOF and the polymer at the interface. For more detail on the synthesis and characterization see the ESI.†
It is interesting to compare the Cr(VI) extraction capacity of Zr-BDC-(NH2)2@PB to state of the art materials reported in the literature. It should be noted that since the Cr(VI) capacity is determined using different anions in aqueous solution, in Table 1 we converted all reported data into mg Cr(VI) per g of sorbent. To the best of our knowledge, our materials have the highest Cr(VI) sorption capacities among MOF-based ion exchangers and adsorbents reported to date. However, some non-MOF-based technologies have been reported with higher capacities (see Table S2†).
For water treatment, the Cr(VI) capture at low ppm levels is crucial. Firstly, simple batch experiments were performed to determine the differences in efficiency in capturing Cr2O72− at low concentrations. In these experiments, 50 mg of adsorbent was added to 5 mL of contaminated water at a concentration of 5 ppm Cr(VI) and a pH ∼ 3, which is typical of industrial wastewater streams.45 As expected, Fig. 1(b) shows that the Zr-BDC-(NH2)2@PB composite again has enhanced Cr(VI) removal when compared to Zr-BDC-(NH2)2 despite having 20% less MOF inside the composite. Considering that the neat polymer has negligible contribution to the Cr(VI) removal, this again indicates that there is some synergy between the MOF and polymer that lends to enhanced extraction even at low concentrations. Next, it was necessary to see if the material is capable of getting solutions below the EPA and WHO standard limit of 100 and 50 ppb, respectively (Fig. 1(c)). For this, Zr-BDC-(NH2)2@PB was placed in 500, and 200 ppb Cr(VI) solutions. After 24 hours, the composite was removed and analysis of the resulting solution indicated that chromium is indeed below the desired concentration. While the pH of the aforementioned solutions did not deviate from the starting pH ∼ 3 upon treatment, a similar adsorption test was also performed in water, at pH = 7, containing 1 ppm Cr(VI). Expectedly, there is a slight decrease in the pH of the purified water after chromium removal, pH = 6 ± 0.1, a direct result of the acidic ion-exchange sites on the internal MOF surface.
Often waste water from various industries can run off into natural water streams, resulting in highly complex mixtures that contain a variety of competing organic and inorganic interferents which can affect the performance of the adsorbent. Hence, efforts were made to test Cr(VI) selectivity in surface water samples. For this, Zr-BDC-(NH2)2@PB was placed in the Rhone river (Sion, Switzerland) water sample that was spiked with 5 ppm Cr(VI). The resulting data, Fig. 1(d), shows no more than 7% change in the performance of Zr-BDC-(NH2)2@PB in the presence of various anions and cations found in river water. While this indicates that the material is an effective adsorbent, even in a complex real water media, there is also an indication that the material is adsorbing a noticeable amount of SO42−, which could likely be responsible for the slight performance reduction.
Another crucial criterion for adsorbents is the rate of extraction, which determines the time required for each adsorption cycle. The kinetic experiment (Fig. 2(a)) shows that in less than 5 minutes, ∼50% of the Cr(VI) is extracted, and in 35 min equilibrium was reached with more than 85% Cr(VI) removed. This is among the faster Cr(VI) extractions reported thus far in the literature (Table 1). Further, it is observed that the PES bead, modified with carboxylates, is faster to equilibrium (by a factor of ∼3) and has a slightly higher extraction efficiency, when compared to the unmodified PES bead. This demonstrates that hydrophilic carboxylic acid groups, which allow for better water contact and diffusion into the Zr-BDC-(NH2)2@PB (Fig. S4†), is a method to improve material performance. This can also be confirmed by EDX mapping data showing the homogenous distribution of Cr in the Zr-BDC-(NH2)2@PB (Fig. 3). From a practical point of view, the rapid capture of Cr(VI) will promote an adsorption system with high flow rates, where the liquid can have shorter contact time with the adsorbent.
From a practical point of view, it is not only important that we can regenerate our material; it is also important to ensure that there is no Cr(VI) in the solution after regeneration. As such, XPS analysis was used to monitor the oxidation state of chromium inside the fully loaded Zr-BDC-(NH2)2@PB before and after exposure to light. Before exposure, Fig. 4 shows two peaks at 577.3 and 579.6 eV, which corresponds to Cr(III) and Cr(VI), respectively.46 It is evident that, after exposure, the peak for Cr(VI) goes away indicating complete reduction. In addition, we analyzed the solution after regeneration for Cr(VI) content via a precipitation of the Cr(III) species using NaOH. After analysis of the remaining supernatant, only a small amount of Cr(VI) remains in the regeneration solution (Fig. S8(c)†). Further, the stability of the Zr-BDC-(NH2)2 crystals upon Cr(VI) capture and regeneration was confirmed by PXRD (Fig. S5†) and SEM (Fig. S6†). Given the propensity of Zr-MOFs to have defects, the number of missing linkers in this material were also quantified via CHN analysis and ICP-OES. On average, ∼2 of every 6 BDC-NH2 linkers are missing, which is likely attributed to the etching effect of the acid47,48 (Table S4†). It should be noted that after long exposure to the HCl solution, ∼24 hours, the crystallinity of Zr-BDC-(NH2)2 is eventually diminished; despite this apparent amorphization, the structure is still intact as proven by FTIR and TGA analyses (Fig. S5†) and the performance remains stable (Fig. S8(a)†). Last, we also performed experiments without light to confirm its impact. The results showed that the adsorption performance remains the same; however, during regeneration, which is carried out in HCl solution and in the dark, only ∼55% of the captured Cr is released (Fig. S8†). Given this, it is thought that the reduced Cr(III) species, produced during light regeneration, is more readily released from the sample in acidic media than Cr(VI).
Cr2O2−7 + 14H+ + 6e− → 2Cr3+ + 7H2O | (1) |
The Cr(III) is released into the solution and the Cl− ions in the acidic environment reactivate the NH3+Cl− adsorption sites for the next cycle. In the absence of a sacrificial reagent, water accepts the holes and the following photocatalytic redox cycle takes place:
h+ + H2O ⇌ OH˙ + H+ | (2) |
The good recyclability of the Zr-BDC-(NH2)2@PB in combination with their high capacity, fast extraction rate and ability to completely photoreduce Cr(VI) to less toxic Cr(III) makes this composite an outstanding candidate for Cr(VI) extraction–photoreduction.
It is interesting to compare the design demonstrated here with other technologies reported in the literature. For instance, filtration columns containing MOF powder were previously reported for Cr(VI) capture; however, in these studies sand filtration columns containing only 1–2 wt% of adsorbent were employed.19,24,30 This is due to the nano/micro-scale MOF particles, which causes difficulties such as clogging, pressure drop, and material loss in liquid-phase adsorption columns. While the sand filler, which offers a larger grain size, helps to avoid these problems, it is thought that this type of technology will lend to large capital costs due to a low volumetric efficiency resulting from large filler to adsorbent ratio. For comparison, Zr-BDC-(NH2)2 was instead structured into milimeter sized Zr-BDC-(NH2)2@PB, which can be employed directly in a column without the need for any filler or support. This allows us to take full advantage of the entire column volume. Further, the pressure drop in the system is drastically reduced in comparison to sand filters due to the larger particle size and more efficient packing. While there are several alternative methods to structure MOFs into particles of different shapes and size, these methods often use high pressures, and the resulting MOF particles have diminished properties when compared to their unstructured counterparts.49,50 The present shaping method leads to minimal loss in MOF surface area, preserves and even enhances the intrinsic properties of the MOF crystals, and provides good mechanical stability to the resulting beads allowing their application in the proposed advanced liquid-phase adsorption system.
For the regeneration process, it is important that the light reaches all the particles in the bed which we achieved by optimizing the N2 flow inside of a transparent glass column (Fig. 5, inset). The column was fed with Cr(VI) solution with a continuous flow of contaminated water having a concentration of 5 ppm Cr(VI). The Cr(VI) concentration was measured at the outlet of each column (Fig. 5). While a single column can successfully remove more than 90% of Cr(VI) over a large operational window, a second column was employed to achieve the EPA drinkable concentration, below 100 ppb. After ∼6 hours of adsorption, the Cr(VI) concentration goes above the EPA limit. Next, the columns is regenerated by draining the water and filling the column with HCl solution while irradiating the columns with visible light. To test that all Cr(VI) was converted to Cr(III), the Cr(III) species were precipitated from the HCl solution via the addition of NaOH and analysis of the supernatant confirms only small amounts of Cr(VI) (Fig. S9†). This regeneration takes ∼4 h which is sufficiently shorter than the adsorption window. Hence, a semi-continuous process can be developed by doubling the size of the proposed setup such that one part is in adsorption and the other in the regeneration mode. Three complete cycles were carried out to demonstrate the performance and recyclability of the integrated system. The operation window of 6 h remains effective during three cycles with the final Cr(VI) concentration well below the targeted 100 ppb at the outlet tank.
As a last step, we confirmed the mechanical stability of the composite beads while under continuous flow for extended periods of time. For this, we performed a single column run with gas sparging for the duration of 80 h. After this period, the beads were tested subsequently for Cr(VI) adsorption (Fig. S11†). Despite the bead plasticity, no deformation was observed during the entire process and the adsorption performance remained the same, demonstrating good mechanical stability of the composite beads during process conditions. In addition, the outlet water stream was analyzed for the presence of Zr. Indeed, only trace amounts of the metal, up to 1.72 ppb, was found in the accumulated filtrate solution. This result supports the idea that there are sufficient interactions between the MOF and polymer, which inhibit the loss of Zr-BDC-(NH2)2 from the bead during the continuous flow process.
Footnotes |
† Electronic supplementary information (ESI) available: Experimental details. See DOI: 10.1039/d0ta01046d |
‡ Current address: Helen Scientific Research and Technological Development Co., Ltd., Ho Chi Minh City, Vietnam. |
This journal is © The Royal Society of Chemistry 2020 |