Issue 17, 2014

Do voltammetry electrodes modified with MIPs really work? The role of large molecules: folic acid as a probe

Abstract

There are many uncertainties concerning the use of molecularly imprinted polymers (MIPs) as electrode modifiers. In order to contribute to clarification of this issue, a large target molecule was used to prepare an MIP-modified composite electrode. The MIP was synthesized using folic acid (FA) as a template, and employed in the modification of composite electrodes based on graphite and polyurethane (GPU), varying its percentage from 2.5 to 10%. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to compare the performance of modified and unmodified electrodes. After optimization of the electrode composition, pH, and the electrolytic medium, the best results for which were obtained using 2.5% MIP, pH 4.5 and acetate buffer, respectively, differential pulse voltammograms were used to obtain analytical curves for electrodes modified with the 2.5% MIP or 2.5% non-imprinted polymer (NIP), as well as for the unmodified GPU electrode. Although the sensitivities were similar in all cases, the electrode modified with 2.5% MIP presented a lower limit of detection (LOD) of 0.17 μmol L−1 and 0.034 μmol L−1 for the cathodic peaks in −0.52 and −0.58 V (vs. SCE), respectively, under specific conditions, allowing the determination of FA in commercial pharmaceutical formulations with results that were in agreement with the official HPLC method. Finally, evaluation was made of the interference of a structurally similar molecule, the methotrexate, as well as small molecules containing functional groups similar to those present in the structure of FA, such as uric acid, ascorbic acid and dopamine. The 2.5% MIP electrode was more selective than the 2.5% NIP electrode.

Graphical abstract: Do voltammetry electrodes modified with MIPs really work? The role of large molecules: folic acid as a probe

Article information

Article type
Paper
Submitted
11 မတ် 2014
Accepted
10 ဇွန် 2014
First published
11 ဇွန် 2014

Anal. Methods, 2014,6, 6658-6667

Author version available

Do voltammetry electrodes modified with MIPs really work? The role of large molecules: folic acid as a probe

A. V. Pereira, P. Cervini and É. T. Gomes Cavalheiro, Anal. Methods, 2014, 6, 6658 DOI: 10.1039/C4AY00616J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements