Issue 9, 2020

Characterization of iron oxide nanoparticles by means of single-particle ICP-mass spectrometry (SP-ICP-MS) – chemical versus physical resolution to overcome spectral overlap

Abstract

As a result of their unique physical, chemical and/or biological properties, the use of engineered nanoparticles (ENPs) is growing very rapidly. Iron oxide nanoparticles (IONPs) are of particular interest owing to their magnetic properties, and thus the development of suitable methods for their characterization is essential. Inductively coupled plasma-mass spectrometry (ICP-MS) operated in single-particle (SP) mode provides different types of relevant information, such as size distribution and particle number and mass concentrations. However, the use of SP-ICP-MS becomes less straightforward when the analyte signal is subject to spectral overlap. In the case of IONPs, characterization by means of SP-ICP-MS is hindered by the occurrence of ArO+ polyatomic ions with the same nominal mass-to-charge (m/z) ratio as the most abundant Fe isotope. In this work, different approaches relying on either chemical or physical (mass) resolution, to avoid this spectral interference otherwise jeopardizing accurate results, were assessed. In the case of chemical resolution, the performance of on-mass and mass-shift approaches was evaluated using different types of quadrupole-based ICP-MS instrumentation, including single-quadrupole (SQ) and tandem ICP-MS (ICP-MS/MS) units. Physical resolution was accomplished using a new generation of sector field (SF) ICP-MS instrumentation, capable of dealing with transient signals of extremely short duration (10–100 μs dwell time), even when operated at higher mass resolution (pseudo-resolution mode). Based on the figures-of-merit obtained for the different approaches evaluated, an on-mass approach using NH3 as the reaction gas in SQ-ICP-MS, an on-mass approach using H2 as the collision/reaction gas in ICP-MS/MS and pseudo-medium resolution in SF-ICP-MS were found to be the best-suited approaches for fast interference-free monitoring of the ion signals generated by IONPs in SP mode. While the use of chemical (H2/on-mass) and physical (pseudo-medium) resolutions also provided accurate and precise results for custom-made Fe3O4 (magnetite) NPs of ≈50 nm, the use of NH3 was less successful, as it leads to an extension of the SP pulse profile and a lower signal-to-background ratio. Finally, SF-ICP-MS operated in pseudo-medium resolution mode was used for the characterization of Fe3O4 NPs synthesized electrochemically (batch and continuous operation mode).

Graphical abstract: Characterization of iron oxide nanoparticles by means of single-particle ICP-mass spectrometry (SP-ICP-MS) – chemical versus physical resolution to overcome spectral overlap

Supplementary files

Article information

Article type
Paper
Submitted
20 апр. 2020
Accepted
30 јул. 2020
First published
31 јул. 2020

J. Anal. At. Spectrom., 2020,35, 2023-2032

Characterization of iron oxide nanoparticles by means of single-particle ICP-mass spectrometry (SP-ICP-MS) – chemical versus physical resolution to overcome spectral overlap

A. Rua-Ibarz, E. Bolea-Fernandez, G. Pozo, X. Dominguez-Benetton, F. Vanhaecke and K. Tirez, J. Anal. At. Spectrom., 2020, 35, 2023 DOI: 10.1039/D0JA00183J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements