Issue 3, 2013

Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction

Abstract

Elemental speciation in cells is significant for metallomics research. In this study, novel methods of (on-chip) magnetic solid phase extraction (MSPE) combined with high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) were proposed for selenium speciation in selenium-enriched yeast cells. An integrated microfluidic chip consisting of reaction, mixing, and extraction units was designed and fabricated for on-chip MSPE. Sulfonated polystyrene-coated magnetic nanoparticles (Fe3O4@PSS MNPs) were prepared as adsorption material for MSPE of selenoamino acids and selenopeptide. The factors affecting the extraction performance of the target selenium species by (on-chip) MSPE-HPLC-ICP-MS were systematically investigated. The analytical performance of the (on-chip) MSPE-HPLC-ICP-MS was evaluated under individual optimal conditions. The limits of detection for five target selenium species were 0.025 μg L−1 to 0.090 μg L−1 and 0.057 μg L−1 to 0.149 μg L−1 for MSPE-HPLC-ICP-MS and on-chip MSPE-HPLC-ICP-MS, respectively. The MSPE-HPLC-ICP-MS method is sensitive, fast, easy-to-operate, and economical. The on-chip MSPE-HPLC-ICP-MS method has the unique advantages of low sample consumption and high integration; thus, it is suitable for selenium speciation in a small number (∼800) of selenium-enriched yeast cells. A Certified Reference Material of SELM-1 yeast was used to validate the accuracy of the developed (on-chip) MSPE-HPLC-ICP-MS methods. The proposed methods were successfully applied to the speciation of selenium in selenium-enriched yeast cells. Analysis of approximately 800 cells by on-chip MSPE-HPLC-ICP-MS revealed that the average amounts of selenocystine (SeCys2) and selenomethionine (SeMet) in a single selenium-enriched yeast cell are in the order of subpicograms.

Graphical abstract: Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction

Supplementary files

Article information

Article type
Paper
Submitted
09 окт. 2012
Accepted
17 дек. 2012
First published
18 дек. 2012

J. Anal. At. Spectrom., 2013,28, 334-343

Speciation of selenium in cells by HPLC-ICP-MS after (on-chip) magnetic solid phase extraction

B. Chen, B. Hu, M. He, Q. Huang, Y. Zhang and X. Zhang, J. Anal. At. Spectrom., 2013, 28, 334 DOI: 10.1039/C2JA30280B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements