Issue 9, 2016

Determination of free methionine in human blood plasma by species-specific isotope dilution HPLC-ICP-MS using 34S-labelled methionine

Abstract

A species-specific Isotope Dilution (ID) method is described for the determination of free methionine in human blood plasma by High Performance Liquid Chromatography - Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) using 34S-labelled methionine as species-specific spike. The 34S-labelled methionine was obtained from yeasts grown in a medium enriched with 34S (>91%) in the form of sulphate. Methionine was extracted from yeasts using enzymatic digestion with protease XIV followed by isolation using preparative reverse phase HPLC. Two separate batches of the labelled methionine standard were obtained. The 34S-labelled methionine standard solutions obtained were characterised both in terms of 34S isotope enrichment (82.7 ± 0.6%) and total sulfur concentration (396 ± 6 μg g−1) by reverse Isotope Dilution HPLC-ICP-MS using a natural abundance methionine standard solution and a multicollector instrument working in the pseudo-high resolution mode to avoid spectral interference. Additionally, the identity of the 34S-labelled methionine isolated by preparative HPLC and its isotope enrichment was confirmed by Gas Chromatography-Mass Spectrometry (GC-MS). Human blood plasma samples were spiked with the 34S-labelled methionine spike. Then, plasma proteins were precipitated with trifluoroacetic acid and separated by centrifugation. Methionine was separated from the rest of sulfur containing compounds by reversed phase chromatography in isocratic mode using a mobile phase of 75 mM ammonium acetate (pH 7.4) containing 2% of methanol. The retention time of methionine (8.3 minutes) was confirmed by fortifying the samples with natural abundance methionine and also by collecting the methionine peak and further analysis by GC-MS. Finally, methionine in human blood plasma samples was determined by measuring the signals for 32S and 34S in a double focusing ICP-MS instrument working at medium resolution (R = 4000). Concentrations were calculated by integrating the methionine peak for both masses and applying the isotope dilution equation after mass bias correction. The recoveries for samples fortified at different concentration levels ranged between 98.4 and 100.5%. Additionally, good agreement was obtained between the results found with this method and those reported by the clinical laboratory using a validated routine method.

Graphical abstract: Determination of free methionine in human blood plasma by species-specific isotope dilution HPLC-ICP-MS using 34S-labelled methionine

Article information

Article type
Paper
Submitted
04 اپریل 2016
Accepted
12 جوٗلایی 2016
First published
12 جوٗلایی 2016

J. Anal. At. Spectrom., 2016,31, 1885-1894

Determination of free methionine in human blood plasma by species-specific isotope dilution HPLC-ICP-MS using 34S-labelled methionine

O. Galilea San Blas, F. Moreno Sanz, P. Herrero Espílez, B. Prieto García, F. V. Álvarez Menéndez, J. M. Marchante-Gayón and J. I. García Alonso, J. Anal. At. Spectrom., 2016, 31, 1885 DOI: 10.1039/C6JA00125D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements