Issue 19, 2023

An ultrasensitive photoelectrochemical assay for tumor necrosis factor-alpha based on hollow CdS cubes as a signal generator and NiCo2O4-Au as a signal extinguisher

Abstract

Sensitive detection of tumor necrosis factor-alpha (TNF-α) in human serum is beneficial for finding cancer patients early due to overexpressed TNF-α being related to some cancers. Here, a photoelectrochemical (PEC) aptasensor was constructed for ultrasensitive TNF-α assay based on the signal generator of hollow CdS cubes (H-CdS) and the signal extinguishing activity of NiCo2O4-Au. In this work, compared with traditional solid CdS, H-CdS could greatly promote the PEC signal because its hollow structure could accelerate the separation of photogenerated charges, which also possesses abundant active sites and high light absorption capability. Moreover, H-CdS can be prepared facilely with Cd-based Prussian blue analogs as the precursor. Meanwhile, NiCo2O4-Au was fabricated and utilized as a signal extinguisher. In the presence of TNF-α, NiCo2O4-Au could be introduced onto the H-CdS modified electrode, producing competitive consumption of the electron donor effect, the p-n semiconductor quenching effect, and the mimetic enzymatic catalytic precipitation effect, which all can significantly reduce the PEC signal. Based on the signal extinguishing activity of NiCo2O4-Au and the signal generator of H-CdS, TNF-α can be detected sensitively with a lower detection limit (0.63 fg mL−1) and a wide linear range (1 fg mL−1– to 1 ng mL−1), which may have a potential application in the PEC bioanalysis field and the disease diagnostics field.

Graphical abstract: An ultrasensitive photoelectrochemical assay for tumor necrosis factor-alpha based on hollow CdS cubes as a signal generator and NiCo2O4-Au as a signal extinguisher

Supplementary files

Article information

Article type
Paper
Submitted
18 جوٗلایی 2023
Accepted
10 اگست 2023
First published
11 اگست 2023

Analyst, 2023,148, 4746-4752

An ultrasensitive photoelectrochemical assay for tumor necrosis factor-alpha based on hollow CdS cubes as a signal generator and NiCo2O4-Au as a signal extinguisher

Y. Fu, B. Fan, S. Chang, D. Guo, F. Wang and Q. Pan, Analyst, 2023, 148, 4746 DOI: 10.1039/D3AN01225E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements