Issue 8, 2014

Fast analysis of β-ecdysone in Brazilian ginseng (Pfaffia glomerata) extracts by high-performance liquid chromatography using a fused-core column

Abstract

The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of a fast analysis method for β-ecdysone in extracts of Pfaffia glomerata. A step-by-step strategy was used to optimize temperature (30–55 °C), flow rate (1.0–2.0 mL min−1), mobile phase composition (mixtures of water and methanol or acetonitrile) and equilibration time (1–5 min). A gradient method has been developed using two solvents: 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile. Optimized conditions provided a method for the separation of β-ecdysone in approximately 2 min with a total analysis time (sample-to-sample) of 9 min, including the return to initial conditions and the re-equilibration of the column. Evaluation of chromatographic performance revealed excellent intraday and interday reproducibility (>99.5%), resolution (2.78), selectivity (1.13), and peak symmetry (1.09) while presenting low limits of detection (0.20 mg L−1) and quantitation (0.67 mg L−1). The robustness of the method has also been calculated according to the concentration/dilution of the sample. Several sample solvents were evaluated and the best chromatographic results were obtained using 80% methanol in water. Finally, the developed method was validated with different extracts of Pfaffia glomerata samples.

Graphical abstract: Fast analysis of β-ecdysone in Brazilian ginseng (Pfaffia glomerata) extracts by high-performance liquid chromatography using a fused-core column

Article information

Article type
Paper
Submitted
19 دسمبر 2013
Accepted
31 جنؤری 2014
First published
03 فرؤری 2014

Anal. Methods, 2014,6, 2452-2459

Author version available

Fast analysis of β-ecdysone in Brazilian ginseng (Pfaffia glomerata) extracts by high-performance liquid chromatography using a fused-core column

M. A. Rostagno, I. C. N. Debien, R. Vardanega, G. C. Nogueira, G. F. Barbero and M. A. A. Meireles, Anal. Methods, 2014, 6, 2452 DOI: 10.1039/C3AY42276C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements