Issue 9, 2022

Sensitive determination of chromium by inductively coupled plasma mass spectrometry using chelate-enhanced nebulized film dielectric barrier discharge vapor generation

Abstract

In this work, a novel and sensitive procedure for Cr determination by inductively coupled plasma mass spectrometry (ICP-MS) with a chelate-enhanced nebulized film dielectric barrier discharge (NFDBD) vapor generation sampling system was developed. Using sodium diethyldithiocarbamate (DDTC) as a chelating reagent, the sensitivity of Cr(VI) was specifically increased 10.5-fold by the DDTC-enhanced NFDBD sampling system compared with pneumatic nebulization. The enhancement mechanism and the experimental parameters for Cr(VI) determination such as the DDTC concentration, the solution pH, the input discharge voltage and the argon (DBD plasma gas) flow rate were evaluated in detail. The interferences from the sample matrix at 10–100 mg L−1 level were found negligible for trace Cr(VI) determination in the NFDBD sampling system. Under optimized conditions, the relative standard deviation for Cr(VI) was 1.4% at the concentration of 5 μg L−1 and the detection limit for Cr(VI) was 0.023 μg L−1. After oxidation of the Cr species to Cr(VI), the total Cr in environmental and biological samples could be sensitively determined by this DDTC-enhanced NFDBD-ICP-MS system. The determined values of the total Cr (29.8 ± 0.3 ng g−1 and 402.8 ± 18.8 ng g−1) in the standard reference materials of the simulated natural water sample (GBW08608) and biological tissue sample (GBW10210) agreed well with the certified values (30 ± 2 ng g−1 and 0.4 ± 0.08 μg g−1), respectively. It is also worth noting that this is the first report to use DBD induced vapor generation of Cr. Compared with other sampling techniques such as chemical vapor generation and electrothermal vaporization, this proposed technique has a competitive detection limit for trace Cr determination. Furthermore, it eliminates the additional reducing agent for vapor generation, and could operate with low cost and low power (≤65 W).

Graphical abstract: Sensitive determination of chromium by inductively coupled plasma mass spectrometry using chelate-enhanced nebulized film dielectric barrier discharge vapor generation

Supplementary files

Article information

Article type
Paper
Submitted
07 جوٗلایی 2022
Accepted
20 جوٗلایی 2022
First published
27 جوٗلایی 2022

J. Anal. At. Spectrom., 2022,37, 1876-1882

Sensitive determination of chromium by inductively coupled plasma mass spectrometry using chelate-enhanced nebulized film dielectric barrier discharge vapor generation

Q. He, C. Li, X. Kong, M. Zhao and J. Zhang, J. Anal. At. Spectrom., 2022, 37, 1876 DOI: 10.1039/D2JA00235C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements