Arash
Asfaram
*a,
Hossein
Sadeghi
a,
Alireza
Goudarzi
b,
Esmaeel
Panahi Kokhdan
a and
Zeinab
Salehpour
a
aMedicinal Plants Research Center, Yasuj University of Medical Sciences, Yasuj, Iran. E-mail: arash.asfaram@yums.ac.ir
bDepartment of Polymer Engineering, Golestan University, Gorgan 49188-88369, Iran
First published on 14th January 2019
A dispersive micro solid-phase extraction (DMSPE) technique was developed using manganese-oxide nanoparticles loaded on activated carbon (Mn3O4-NPs-AC) as an effective sorbent combined with ultrasound for the extraction and determination of a trace amount of thymol and carvacrol in methanolic extracts of Thymus daenensis, Salvia officinalis, Stachys pilifera, Satureja khuzistanica and mentha, and water samples. Thymol and carvacrol phenolic compounds were extracted from real samples using acetonitrile (ACN) as the desorption solvent. Using central composite design (CCD), the effects of pH, ionic strength (NaCl), nano-sorbent mass, contact time, and desorption volume were investigated. Additionally, based on five-level variables, response surface methodology was used to determine the individual and interactive effects between factors on the process. The optimized extraction conditions included 12 mg of Mn3O4-NPs-AC as the sorbent, 300 μL of ACN as the desorption solvent, pH 3.0, 0.5 w/v% of NaCl, and 4.5 min sonication time. Under the optimized conditions, for all the samples, the limits of detection were 0.054–0.104 ng mL−1 and the limits of quantification were 0.178–0.345 ng mL−1. The correlation coefficients of the calibration curves were >0.985, i.e. in the range of 0.4–6000 ng mL−1. To validate the effects of the matrix, the recovery, reproducibility, repeatability, and overall uncertainty were calculated for the five methanolic extracts, at 50, 100, and 500 ng mL−1. The recovery ranged between 94.5% and 109.0% with a relative standard deviation of <8.0% for the repeatability and reproducibility precision, which strongly supports the favorable repeatability and reproducibility of the method. The presented method also has the excellent sorbent features of NPs for the sorption of the analyte, which is due to the use of ultrasound for dispersion of the material in the sample matrix.
Thymol and carvacrol are phenolic volatile monoterpenes found in essential oils of different herbs, chiefly at concentrations between 20% and 98%.4,5 These two substances have been affirmed for their antimicrobial activity, mainly against Gram-positive microorganisms,6 and have a wide range of applications in the food and veterinary industries, to combat antibiotic-resistant pathogenic microorganisms.7
Thymus daenensis,8,9Salvia officinalis,10Stachys pilifera,11Satureja khuzistanica,12 and mentha are well-known plant species composed of thymol and carvacrol, together with their major components. Hence, developing a simple and an efficient method for the extraction and quantification of such antioxidants has been the goal of many scientists.4,13,14
High performance liquid chromatography (HPLC) has hitherto been the most popular method, owing to its relatively low cost and universality for the analysis of phenolic compounds.13,15,16 However, prior to chromatographic analysis, due to the intricate matrix effect and the low levels of analytes in the actual samples, performing a simple and an efficient sample pretreatment process for the elimination of the interferents and enrichment of the analytes is highly required.17–20
Sample preparation is a key process before the analysis of organics in water samples.21–23 In the selection of a sample preparation method, time consumption plays a central role since short time assists in enhancing the working efficiency.24,25 Therefore, to attain ultrafast extraction, the diffusion distance both in the aqueous phase and in the extraction phase needs to be reduced in the shortest time, which means that the micro-extraction phase should be very small.26 To achieve this goal, it is better for the micro-extraction phase to be well dispersed in the sample solution, rather than aggregated or stacked together. Hence, the diffusion distance in the sample solution could be diminished effectively at the micro level.22,23,27,28
More recently, a new method of solid-phase extraction (SPE), namely solid-phase microextraction (SPME), has been increasingly utilized.29 Compared to traditional SPEs, SPME uses a trace of solid phase for extraction (i.e. of the order of μg), thereby minimizing the consumption of sorbent and maximizing the extraction process.30 Dispersive micro-solid phase extraction (DMSPE) is one of the extraction techniques in which the volume of extraction phase is very small, and the extraction efficiency depends on the distribution of the target analytes between the extraction phase and the sample solution.31 The greater the tendency of the analytes to accumulate in the extraction phase, the more is extracted, hence increasing the extraction efficiency. In the DMSPE method, in the extraction phase, the analyte is absorbed through a solid phase with the aid of magnetic stirring, vortexing, or ultrasonication. The analyte is then rinsed with a solvent or a mixture of organic solvents.32 In this method, the mixture of the analytes by ultrasonication leads to an increase in mass transfer to the solid phase. In spite of the reduction in the volume of organic solvents in SPME, the use of ultrasound means that it is performed faster due to the formation of fine droplets and the increase in the contact surface between the two liquid transfer fluids. Therefore, new miniaturized approaches such as DMSPE provide numerous advantages such as suitability for analyzing very small amounts of analyte, consumption of small amounts of sorbent, and low use of toxic organic solvents.33,34
On the basis of our experiences with manganese-oxide nanoparticles (Mn3O4-NPs) and based on the data from the literature, these particles have the ability of strong surface complexing for sorption of phenolic compounds with fast kinetics. Physicochemically, they have also been shown to be highly stable against acids, alkalis, oxidants, and reductants35 and to be non-toxic and poorly soluble in water.36 Application of metal nanomaterials has been demonstrated to elevate, to a great extent, the sorption capacities of phenolic compounds because of the special features of nano-scaled materials, i.e. high surface-area-to-volume ratio and homogeneous distribution in solution.37,38 The presence of hydroxyl groups in phenolic molecules makes these molecules a good candidate for extraction from real matrices by Mn3O4-NPs.
In the DMSPE method, the extraction efficiency may be affected by various factors, especially type and volume of desorption solvent, pH, nano-sorbent mass, and extraction time. Therefore, it is important to optimize the extraction conditions.39,40 To better examine the parameters in DMSPE using Mn3O4-NPs-AC, the procedures of experimental design are a preferable option.41 By considering the interaction and quadratic effects, these procedures are able to fit second-order response surfaces, thereby optimizing the experimental conditions more effectively with relatively minimal experimental trials.42,43
A literature review indicates that no DMSPE method has been previously reported using Mn3O4-NPs loaded on activated carbon (Mn3O4-NPs-AC) for the extraction of phenolic compounds, including thymol and carvacrol. Therefore, in the present investigation, DMSPE was used to extract these phenolic compounds from Thymus daenensis, Salvia officinalis, Stachys pilifera, Satureja khuzistanica, mentha, and water samples prior to their determination by HPLC-UV. For this purpose, the effective parameters in the DMSPE extraction method for the two analytes were investigated and optimized by the experimental design approach, central composite design (CCD). The type of desorption solvent can be readily optimized by the one-variable-at-a-time approach. The DMSPE method was validated for precision, repeatability, recovery, and qualitative and quantitative limits and was employed to determine phenolic compounds.
HPLC was carried out using a Knauer system (Berlin, Zehlendarf, Germany), equipped with a UV-VIS 2500 Detector. The separation of analytes was performed on a Knauer column (4.6 mm diameter × 250 mm length, particle size of 5 μm, Eurospher 100-5 C18) with a pre-column (Eurospher 100-5 C18). The mobile phase included 55% ACN and 45% (v/v) water, delivered from separate pumps. The flow rate remained at 1.1 mL min−1 with UV detection at 220 nm, and the column temperature was set at room temperature. All of the other instruments applied in this research have been fully described in our previous publications.44,45
In this study, various extraction-controlling parameters (pH, nano-sorbent mass, extraction time, ionic strength (NaCl), and desorption volume) were optimized by response surface methodology (RSM)-based CCD. For each variable, five levels (0, −α, +α, −1, and +1) were assigned as the central points, low axial runs, high axial runs, low fractional factorials, and high fractional factorials, respectively, based on the CCD principle. The percentages of extraction recovery (ER%) of carvacrol and thymol were chosen as the response variables, whereas solid pH (X1), ionic strength (X2), nano-sorbent mass (X3), extraction time (X4), and desorption volume (X5) were selected as the independent variables. The obtained experimental data fitted to the second-order polynomial model have been fully explained in our and other previous investigations.46,47
In this well-designed CCD model, with the goal of maximizing the recovery of thymol and carvacrol, we analyzed the impacts of the five independent variables on the response functions and evaluated the optimal preparation conditions. To ensure the accuracy of the model, conducting analysis of variance (ANOVA) is necessary; therefore, we used this method to affirm the linear, quadratic and interaction regression coefficients, individually. The statistical analysis of the computed F-value at P < 0.05 was performed in order to evaluate the importance of the dependent variables. Two variables that showed interactive effects on the process responses were maintained at the same time by fixing the other variable at its central point (i.e. 0). These effects were depicted using the 3D response surface plots drawn based on the fitted quadratic equation.
Fig. 2a shows the histogram of Mn3O4-NP size distribution. The diameters of the Mn3O4-NPs were in a wide range of 30–70 nm. The average diameter of the Mn3O4-NPs was 58 nm, which was close to the SEM result. The chemical composition of the prepared Mn3O4-NPs-AC was studied by energy dispersive X-ray (EDX) analysis. The C, Mn, and O peaks detected in the EDX spectrum of the Mn3O4-NPs-AC are shown in Fig. 2b. These results confirmed that the particles were composed of manganese and oxygen elements.
Fig. 2 Particle size distribution (a), EDX analysis (b), N2 adsorption/desorption isotherms (c), and XRD pattern (d) of Mn3O4-NPs-AC. |
The type IV isotherm patterns with H3 hysteresis loops can be observed from the adsorption/desorption curves of the nano-sorbent, which shows a mesoporous structure (Fig. 2c). The Brunauer–Emmett–Teller surface area of the nano-sorbent is 310 m2 g−1, and the total pore volume is 0.392 cm3 g−1.
The X-ray diffraction (XRD) pattern of the prepared Mn3O4-NPs-AC was investigated in the 2θ region of 10–80°. According to the XRD pattern (Fig. 2d), the diffraction peak at 2θ of 24.0° was attributed to the planar structure of AC. Likewise, all of the characteristic diffraction peaks of a pure tetragonal crystal of Mn3O4-NPs at 2θ of 18.0° (101), 28.88° (112), 31.016° (200), 32.32° (103), 36.10° (211), 36.45° (202), 38.00° (004), 44.45° (220), 49.82° (204), 50.71° (105), 53.86° (312), 56.01° (303), 58.51° (321), 59.84° (224), 64.65° (400), 69.66° (305), 74.15° (413), 76.58° (422), and 77.51° (404) were also present for the Mn3O4-NPs-AC, further indicating the successful synthesis of Mn3O4-NPs-AC, based on the good agreement with JCPDS card (No. 24-0734).
To attain an estimation of the pure error variance, we used three replicate runs at the center of the design. Using multiple regression analysis, the responses (carvacrol and thymol extraction) were closely related to all five design factors by using the second-order polynomial. Meanwhile, the quadratic regression models for ER% carvacrol and ER% thymol in terms of actual factors such as pH (X1), ionic strength (X2), nano-sorbent mass (X3), extraction time (X4), and desorption volume (X5) are given by eqn (1) and (2), respectively:
(1) |
(2) |
The significance and the fitness of the models was tested by ANOVA (Table S2†). The high “Model F-values” (59.69 for carvacrol and 43.66 for thymol) suggest that the models are significant, and there is a 0.01% chance of “Model F-values” this large happening owing to noise.45
The “Lack of Fit F-values” of 2.72 and 4.82 for carvacrol and thymol, respectively, reveal that the models are insignificant; there is a chance of 14.6% for carvacrol and 5.3% for thymol that the “Lack of Fit F-value” occurred because of noise.18 The high values of correlation coefficient (R2; 0.991 for carvacrol and 0.990 for thymol) for eqn (1) and (2) show the significance of the models and indicate a good connection between the observed values and the predicted values of the responses (Fig. 4).
Fig. 4 The observed values for thymol and carvacrol determination plotted against the predicted values calculated from the CCD. |
In this study, X2, X22, X1X2, X2X3, and X32 for carvacrol and X2, X2X5, and X1X3 for thymol were not significant factors for both responses. On the contrary, X1, X3, and X4 were significant for both responses. The resulting effects and the significance of each factor are observable using a Pareto chart (Fig. S2†). Using this chart, it is feasible to accentuate the significant factors exceeding the vertical line (P = 0.05). Moreover, it is possible to detect the relationship and the magnitude of the effect of these factors, which is described by the signal and the value on each horizontal bar.
The adequate precision, a signal/noise ratio measuring the errors in the predictions at the design points, was found to be in the desirable range (<4).29 The values of adequate precision were obtained as 30.68 and 26.70 for carvacrol and thymol, respectively, suggesting the capability of the developed quadratic models in navigation of the CCD design. The value of the coefficient of variance, which represents the error between the observed data and predicted data, was observed to be 4.6% for both responses. In addition, the value of coefficient of variance was <10%, which showed that the error in the model is non-significant.48
As it is apparent from Fig. 5, the responses of both thymol and carvacrol reduce with pH elevation for all of the target solutions. The reason for this phenomenon could be due to the presence of carboxyl and hydroxyl groups on the sorbent, which can be ionized at high pH. These two groups are polar acidic, and at low pH, they are in the neutral form; therefore, both carboxyl and hydroxyl groups are appropriate for adsorption of polar analytes such as thymol and carvacrol. The highest extraction efficiency for the proposed nano-sorbent was achieved at pH 3.0 (Fig. 5a and b). Basically, in aqueous solutions, the speciation of compounds that are weakly acidic is related to the solution properties, i.e. its pH value. It has been demonstrated that acidification of water solutions can reduce the dissociation of weakly acidic analytes, which may raise the extraction efficiency of the target compounds in the case of the strong binding of the non-dissociated form to the sorbent.49,50 In this situation, these acidic drugs have an interaction with the nano-sorbent surface through hydrophobic and π interactions, as well as hydrogen-bond formation.51
The enhancement of the extraction efficiency depends on time up to 4.5 min (Fig. 5a and c). This result demonstrated that 4.5 min is sufficient time for the complete equilibration of the sample solution and the sorbent. Therefore, this time was chosen as the optimal extraction time for further studies, since it is supposed to be able to achieve a balance between the extraction amount and the extraction time. However, extraction times longer than 4.5 min decrease the extraction efficiency, which is likely due to interchange of adsorbed analytes and other species in the aqueous solution.
As can be seen in Fig. 5c and d, the ER of the analytes increased with nano-sorbent mass, which is because of the high specific surface area and small particle size of the sorbent. The extraction rate increased noticeably at a greater surface area and ratio of analyte to available sorption sites. On the other hand, nano-sorbents such as Mn3O4-NPs-AC have a high surface-area-to-volume ratio; therefore, the diffusion route of the analytes is short, which results in rapid and high extraction performance.
The desorption solvent volume in DMSPE has two opposite effects on the extraction efficiency. This means that with the elevation of the solvent volume, the solid–liquid equilibrium of the analytes shifts to the solvent phase, and, therefore, dilution of the final extract increases. In other words, the elevation of the solvent volume causes an increase in the extraction efficiency (Fig. 5b and d).
Experiments were performed in triplicate under the optimal extraction conditions, and a comparison was carried out between the mean values of the observed results and the predicted values. Under the optimum conditions, the extraction amounts of carvacrol and thymol from real samples were 98.89% and 99.45%, respectively, which were close to the predicted value of 100%. The results obtained from confirmation experiments indicated that the model is adequate for predicting the expected optimization.
Real samples | Added (ng mL−1) | Found (ng mL−1) | RR%b | RSD (%) | |||
---|---|---|---|---|---|---|---|
Carvacrol | Thymol | Carvacrol | Thymol | Carvacrol | Thymol | ||
a Intra-day. b Relative recovery (RR%). c Not detected. | |||||||
Double-distilled water | 0.0 | NDc | ND | — | — | — | — |
50 | 49.78 | 49.92 | 99.55 | 99.85 | 2.52 | 2.56 | |
100 | 102.58 | 101.64 | 102.58 | 101.64 | 3.19 | 3.34 | |
500 | 495.19 | 493.16 | 99.04 | 98.63 | 1.39 | 1.37 | |
Thymus daenensis Celak | 0.0 | 81.70 | 101.69 | — | — | — | — |
50 | 135.82 | 153.28 | 108.24 | 103.17 | 4.41 | 4.80 | |
100 | 184.55 | 198.04 | 102.85 | 96.35 | 4.75 | 3.58 | |
500 | 577.37 | 615.41 | 99.13 | 102.74 | 1.91 | 5.20 | |
Salvia officinalis | 0.0 | 33.29 | 31.59 | — | — | — | — |
50 | 85.64 | 83.07 | 104.70 | 102.97 | 4.23 | 5.12 | |
100 | 128.01 | 137.57 | 94.72 | 105.98 | 3.60 | 2.42 | |
500 | 541.85 | 524.36 | 101.71 | 98.55 | 1.41 | 1.54 | |
Stachys pilifera | 0.0 | 109.91 | 55.47 | — | — | — | — |
50 | 159.26 | 102.71 | 98.70 | 94.49 | 3.55 | 3.96 | |
100 | 212.62 | 158.19 | 102.71 | 102.72 | 2.71 | 4.54 | |
500 | 632.53 | 554.78 | 104.52 | 99.86 | 1.97 | 2.18 | |
Satureja khuzistanica | 0.0 | 76.32 | 76.47 | — | — | — | — |
50 | 127.98 | 127.42 | 103.33 | 101.89 | 4.49 | 3.50 | |
100 | 171.54 | 178.83 | 95.22 | 102.36 | 2.89 | 5.00 | |
500 | 575.02 | 591.27 | 99.74 | 102.96 | 2.33 | 4.04 | |
Mentha | 0.0 | 68.78 | 6.08 | — | — | — | — |
50 | 117.37 | 57.27 | 97.18 | 102.37 | 2.22 | 2.44 | |
100 | 173.04 | 110.48 | 104.26 | 104.40 | 4.14 | 4.44 | |
500 | 566.44 | 519.68 | 99.53 | 102.72 | 1.56 | 3.06 |
Real samples | Added (ng mL−1) | Found (ng mL−1) | RR%b | RSD (%) | |||
---|---|---|---|---|---|---|---|
Carvacrol | Thymol | Carvacrol | Thymol | Carvacrol | Thymol | ||
a Inter-day. b Relative recovery (RR%). c Not detected. | |||||||
Double-distilled water | 0.0 | NDc | ND | — | — | — | — |
50 | 51.11 | 50.19 | 102.22 | 100.38 | 2.37 | 5.03 | |
100 | 98.43 | 99.90 | 98.43 | 99.90 | 1.62 | 3.03 | |
500 | 500.97 | 511.45 | 100.19 | 102.29 | 2.18 | 4.81 | |
Thymus daenensis Celak | 0.0 | 81.70 | 101.69 | — | — | — | — |
50 | 131.76 | 155.14 | 100.11 | 106.90 | 7.80 | 6.98 | |
100 | 177.41 | 203.67 | 95.71 | 101.98 | 2.47 | 6.55 | |
500 | 593.55 | 583.20 | 102.37 | 96.30 | 4.63 | 5.67 | |
Salvia officinalis | 0.0 | 33.29 | 31.59 | — | — | — | — |
50 | 87.25 | 83.41 | 107.93 | 103.65 | 6.69 | 5.04 | |
100 | 128.41 | 128.08 | 95.12 | 96.49 | 5.01 | 3.34 | |
500 | 548.77 | 537.75 | 103.10 | 101.23 | 3.73 | 7.56 | |
Stachys pilifera | 0.0 | 109.91 | 55.47 | — | — | — | — |
50 | 157.49 | 103.68 | 95.15 | 96.41 | 6.02 | 7.15 | |
100 | 211.65 | 157.44 | 101.74 | 101.97 | 2.29 | 3.18 | |
500 | 601.58 | 568.81 | 98.33 | 102.67 | 5.50 | 6.98 | |
Satureja khuzistanica | 0.0 | 76.32 | 76.47 | — | — | — | — |
50 | 130.27 | 129.49 | 107.91 | 106.03 | 5.08 | 4.91 | |
100 | 179.42 | 171.38 | 103.10 | 94.91 | 4.39 | 5.33 | |
500 | 557.12 | 600.94 | 96.16 | 104.89 | 2.21 | 4.11 | |
Mentha | 0.0 | 68.78 | 6.08 | — | — | — | — |
50 | 123.26 | 58.80 | 108.97 | 105.44 | 4.31 | 5.76 | |
100 | 163.55 | 103.64 | 94.77 | 97.56 | 6.65 | 6.35 | |
500 | 600.00 | 481.82 | 106.24 | 95.15 | 7.27 | 7.22 |
The obtained extraction recoveries were used to evaluate the accuracy of the model, which ranged from 94.49 to 108.97% with the relative standard deviation (RSD) in the range of 1.37–7.80%. As displayed in Tables 1 and 2, the repeatability for carvacrol and thymol standard solutions was evaluated with three different injections of spiked real samples at three concentration levels (50, 100, and 500 ng mL−1), and the obtained RSD values of ER% were in the range of 1.37–5.20%. The reproducibility was evaluated in the same laboratory but conducted by different operators and under different environmental conditions on three separate days, and the obtained RSD ranged from 1.62% to 7.80%. These results further confirmed the good repeatability and reproducibility of the proposed method.
Method | Sample preparation | Sample | ER (%) | Precision (% RSD) | LOD (ng mL−1) | LOQ (ng mL−1) | Linear range (ng mL−1) | Time (min) | Ref. |
---|---|---|---|---|---|---|---|---|---|
HPLC-UV: High-performance liquid chromatography UV detector. SPE: Solid-phase extraction. GC-FID: Gas chromatography coupled with flame ionization detector. HS-SPME: Headspace solid phase microextraction. HD-HSME: Hydro distillation-headspace solvent microextraction. UAME-NMSPD: Ultrasound-assisted microextraction-nanomaterial solid-phase dispersion. VASEDLLME: Vortex-assisted surfactant-enhanced dispersive liquid–liquid microextraction. GC-MS: Gas chromatography-mass spectrometry. SPME: Solid-phase microextraction. DMSPE: Dispersive micro-solid phase extraction. | |||||||||
HPLC-UV | SPE | Thymus vulgaris L. volatile oil | 96.70–98.70 | 0.80–0.490 | 0.6–1.8 | 2.8–8.6 | 2.0–90000 | >30 | 14 |
GC-FID | SPE | ||||||||
GC-FID | HS-SPME | Human plasma | 81.0–118.0 | 3.87–18.0 | 8.1 | 15 | 8.1–203.5 | 35 | 52 |
GC-FID | HD-HSME | Thymus transcaspicus | 89.0–116.0 | 2.3–9.56 | 230–1870 | 77–6230 | 1250–87500 | 50 | 9 |
HPLC-UV | UAME-NMSPD | Broncho T.D. syrup | 94.50–99.40 | 2.66–4.93 | 0.21–0.23 | — | 5.0–2000 | 15 | 15 |
Thymian syrup | |||||||||
HPLC-UV | VASEDLLME | Broncho T.D. syrup | 93.8–105.2 | 1.02–4.85 | 0.160 | 0.500 | 5.0–4000 | 10 | 20 |
Thymian syrup | |||||||||
Distilled thyme | |||||||||
HPLC-UV | Electrochemical | Peppermint oil | 99.0–108.0 | 3.00–15.0 | 0.81–5.0 | 2.70–57.0 | 10–10000 | 30 | 53 |
Basil oil | |||||||||
Oregano oil | |||||||||
Clove oil | |||||||||
HPLC-UV | SPME | Thyme, Savory, Honey | 94.00–119.0 | 6.80–12.70 | 0.60–0.80 | — | 1.0–80 | >120 | 13 |
GC-MS | HS-SPME | Plasma; milk | — | 2.00–16.00 | 0.31–0.89 | — | 2.0–400.0 | 40 | 4 |
HPLC-UV | DMSPE | –Thymus daenensis | 94.49–108.97 | 1.37–7.80 | 0.054–0.104 | 0.178–0.345 | 0.4–6000 | <10 | This work |
–Salvia officinalis | |||||||||
–Stachys pilifera | |||||||||
–Satureja khuzistanica | |||||||||
–Mentha | |||||||||
–Water samples |
Fig. 6 and Fig. S4–S8† show the chromatograms obtained using the Mn3O4-NPs-AC-based DMSPE method coupled with HPLC-UV for two target compounds in real samples at the spiking concentration of 100 ng mL−1.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c8an02338g |
This journal is © The Royal Society of Chemistry 2019 |