T.
Saito
*a,
T.
Hamamoto
b,
T.
Mizuno
c,
T.
Iwatsuki
d and
S.
Tanaka†
b
aAdvanced Science Research Center, Japan Atomic Energy Agency, 2-4 Shirakata Shirane, Tokai-mura, Ibaraki 319-1195, Japan. E-mail: saito.takumi@jaea.go.jp
bDepartment of Nuclear Engineering and Management, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
cHoronobe Underground Research Center, Japan Atomic Energy Agency, 432-2 Hokushin, Horonobe-cho, Hokkaido 098-3224, Japan
dMizunami Underground Research Laboratory, Japan Atomic Energy Agency, 1-64, Yamanouchi, Akeyo-cho, Mizunami-shi, Gifu 509-6132, Japan
First published on 14th May 2015
Colloids in deep underground water play an important role in the migration of radionuclides and are of great concern in the safety assessment of the geological disposal of nuclear wastes. Size distribution and elemental compositions of colloids in granitic and sedimentary deep groundwater were determined by flow-field flow fractionation (Fl-FFF) combined with inductively coupled plasma mass spectrometry (ICP-MS). Great care was taken to examine colloids over a wide range of size and to detect trace elements associated with them. In the granitic groundwater organic colloids and various inorganic elements were found in limited size ranges. The presence of different types of organic colloids was suggested in this groundwater. Most of the inorganic elements exhibited similar size distributions at <10 nm, which largely overlapped with organic colloids rich in fluorophores. In the sedimentary groundwater small organic and probably inorganic colloids were found at <5 nm together with larger inorganic colloids. Organic colloids in this groundwater were homogeneous in terms of their sizes and the compositions of chromophores and fluorophores. The size distribution of inorganic elements at <10 nm depended on their types, indicating the presence of different host colloidal phases.
The nature and amount of colloids in deep groundwater has been an active topic of research for decades.12–15 Vilks et al.12 reported the existence, concentration, and size distribution of groundwater colloids in different geological settings in Canada, using ultrafiltration. Those authors also evaluated the retention of naturally occurring radionuclides such as radium (Ra), thorium (Th), and uranium (U) in groundwater colloids. Degueldre, et al.13 characterized colloids sampled in granitic groundwater and studied their stability and mobility. Criteria for colloid-facilitated transport of contaminants have been proposed, based on reviews of relevant field studies and laboratory experiments.14
One of the difficulties encountered in the analysis of natural colloids is the heterogeneity both in their size and composition. Colloids found in natural water samples tend to exist over a wide range of sizes and consist of different types of materials associating with each other.16,17 Conventional (ultra)filtration techniques only provide discrete information and may not fully resolve such heterogeneity. This is also the case for groundwater colloids. Only recently has detailed size distribution and composition of natural colloids become available with emergence of continuous size fractionation techniques such as flow-field flow fractionation (Fl-FFF),18–21 size exclusion chromatography (SEC),22,23 and capillary electrophoresis.24,25 These techniques can easily be combined with different types of detection methods to probe various properties of colloids.20–23
In Fl-FFF colloids are forced to accumulate near a so-called accumulation wall that is made of a membrane largely permeable for solute and solvent molecules by a force field created by cross flow.26 Smaller colloids tend to be distributed far away from the wall due to their large thermal mobility and are transported faster than larger ones by parabolic laminar tip flow. Fl-FFF has certain advantages over the other techniques: the range and resolution of fractionation can be easily adjusted by changing flow parameters; in theory the retention time of a given colloidal particle, which is the time necessary for the particle to travel through the channel of the Fl-FFF and reach a detector, mathematically relates to its diffusion coefficient and thus to its hydrodynamic diameter (dH). This technique has been widely applied for environmental colloids in surface water and shallow groundwater,18,20,21 but has not been applied for those in deep groundwater mostly due to the relatively low concentrations of colloids in deep groundwater and the difficulty in obtaining deep groundwater samples.19
The objective of this study is to compare the size distribution and elemental compositions of colloids in granitic and sedimentary deep groundwater by Fl-FFF combined with ICP-MS (inductively coupled plasma mass spectrometry). In our previous study colloids in a limited range of size of the granitic groundwater were examined.19 We have extended it by using the gradient cross flow technique27,28 and measuring even larger colloids appearing in the washing step to determine the similarities and differences in the size distribution and compositions of colloids in both the groundwater samples over a wide size range. The comparison of these groundwater samples is of great importance, as their geological settings are potential candidates of repository sites in geological disposal programs of many countries. The Japan Atomic Energy Agency operates two underground research laboratories (URLs) for general feasibility studies of high-level nuclear waste disposal in Japan.29,30 Groundwater samples obtained in these URLs were used in this study, so that alternation of colloids due to sampling was minimized. Fractionated groundwater colloids by Fl-FFF were subsequently analyzed by on-line UV/Vis and fluorescence detectors for organic colloids and ICP-MS for quantification of inorganic constituents, which are either major colloid-building components or minor components binding to them.
pH | ECc (mS m−1) | Ehd (mV) | TOCe (mg L−1) | TICf (mg L−1) | Na+ (mg L−1) | K+ (mg L−1) | F− (mg L−1) | Cl− (mg L−1) | Br− (mg L−1) | |
---|---|---|---|---|---|---|---|---|---|---|
a Measured on September 24th, 2013. b Measured on December 16th, 2013. c Electronic conductivity. d Redox potential against standard hydrogen electrode (SHE). The Eh of the sedimentary groundwater was not measured. e Total organic carbon. f Total inorganic carbon. | ||||||||||
Mizunami, granitica | 9.8 | 77 | 44 | <0.5 | 5.2 | 122 | 0.4 | 9.2 | 200 | 0.4 |
Horonobe, sedimentaryb | 7.2 | 920 | — | 13 | 470 | 2000 | 51 | 0.3 | 2000 | 13 |
Size fractionation by Fl-FFF consists of the three steps. In the focusing step, colloids introduced into the channel are forced into a narrow band using the opposing tip and focusing flows. In the subsequent elution step, the focus flow is turned off and colloids are transported by the tip flow under the force field created by the cross flow with a flow rate of Vc. In the final washing step colloids still retained in the channel are washed out by the tip flow with Vc = 0. With a constant Vc in the elution step one can evaluate the hydrodynamic diameter of a colloid, dH, from the retention ratio, R, defined as a ratio of the retention time (tr) to the void time (t0), which is the elution time of a non-retained component such as sodium azide.26,31
In this study we adapted the gradient cross flow method,27,28 where Vc is decreased over time in order to extend the fractionation range in a given experimental time without a large loss of resolution for relatively smaller sizes. Vc was quadratically decreased as a function of time, t, in the form Vc = 0.9(t − 30)2/900 for the granitic groundwater, and Vc = 1.5(t − 30)2/900 for the sedimentary groundwater. For this method the theoretical relationship between dH and R is no longer valid; instead a linear relationship with an intercept of zero between tr and dH of the vitamin and protein standards under the same measurement conditions as those employed for the analyses of the deep groundwater samples was used to estimate dH of colloids in the groundwater samples from the obtained tr. The biomolecular standards used in this study are vitamin B12 (dH = 1.7 nm), bovine erythrocyte carbonic anhydrase (dH = 4.8 nm), bovine serum albumin (dH = 7.9 nm), sweet potato β-amylase (dH = 11.1 nm), and bovine thyroglobulin (dH = 18.7 nm).32,33 They were purchased from Aldrich and used without further purification. The results of the size calibration of the Fl-FFF system are shown in Fig. 1. The parameters used in the analyses of the granitic and sedimentary groundwater samples are tabulated in Table 2. If we extrapolate the ranges of the size calibration, the ends of the elution step correspond to 138 nm for the granitic groundwater and 46 nm for the sedimentary groundwater. Furthermore, elution of colloids in the washing step was also measured to examine the presence of even larger colloids.
Fig. 1 Size calibration results of the Fl-FFF equipment with the protein and vitamin standards under gradient cross flow for (a) the granitic and (b) sedimentary groundwater samples. |
Channel thickness, w (mm) | 0.26 (0.44) |
Duration of the steps (min) | |
Focusing step | 20 |
Elution step | 30 |
Washing step | 60 (30) |
V t | V f | V c | V out | |
---|---|---|---|---|
a Numbers in parentheses are those used in the analyses of the sedimentary groundwater. b Flow rates of the tip (Vt), focus (Vf), cross (Vc), and detector (Vout) flows. In the elution step Vc and Vt was quadratically decreased from the initial to final values (the numbers separated by slashes), while keeping Vout constant, i.e. Vout = Vt − Vc. | ||||
Flow parametersb (mL min−1) | ||||
Focusing step | 0.1 (0.2) | 1.8 (2.3) | 0.9 (1.5) | 1.0 |
Elution step | 1.9/1.0 | 0 | 0.9/0 | 1.0 |
(2.5/1.0) | 0 | (1.5/0) | ||
Washing step | 1.0 | 0 | 0 | 1.0 |
The effluent from the Fl-FFF was first measured by a UV/Vis detector (SPD-20A, Shimadzu) at 255 nm and then by a fluorescence detector (RF-10AXL, Shimadzu) at the excitation wavelength of 255 nm and the emission wavelength of 475 nm for organic colloids. After the fluorescence detector, the effluent containing size-fractionated colloids were acidified with 5 wt% pure nitric acid, which was introduced at a flow rate of 1.0 mL min−1 using an isocratic pump (GL Sciences, PU 714). The acidification was meant to extract target metal ions from colloids and maximize their detection by ICP-MS. The acidified effluent was transported to an ICP-MS (Agilent 7500cx) after reducing the flow rate to 0.3 mL min−1 using a micro splitter valve (GL science) and mixed with a small amount of a 500 ppb In solution as an internal standard. No collision gas was used for the measurements. A switching valve was inserted after the outlet of the Fl-FFF to introduce external standard solutions for lanthanide elements (AG-MECAL1-ASL-1, AccuTrace) and remaining elements (XSTC-622, SPEX) to calibrate the ICP-MS. The same switching valve was used to directly introduce the groundwater samples to the detectors without fractionation for the determination of the recovery rates of organic colloids and inorganic elements.
The results of the ten representative elements are presented below. The measured isotopes for these elements were 27Al, 43Ca, 55Mn, 56Fe, 65Cu, 88Sr, 95Mo, 139La, 182W, and 238U. For the granitic groundwater the peak concentrations of the isotopes were larger than the quantification limits (QLs), which are defined as 10σ of the corresponding background levels, except for 56Fe and 238U, where σ stands for the standard deviation. For the sedimentary groundwater that of 95Mo was below the QL and close to the detection limit (DL), which is defined as 3σ of the corresponding background levels; that of 238U was close to the QL (93% of the QL).
Granitic | Sedimentary | |
---|---|---|
a The recoveries for 56Fe and 238U were not calculated in the Fl-FFF-ICP-MS analysis of the granitic groundwater sample. | ||
Organic colloids | ||
UV/Vis | 10.1 | 109.9 |
Fluorescence | 26.0 | 101.1 |
Inorganic elements | ||
27Al | 48.1 | 154.7 |
43Ca | 19.7 | 1.9 |
55Mn | 20.3 | 16.7 |
56Fe | —a | 52.2 |
65Cu | 30.7 | 21.4 |
88Sr | 14.1 | 0.3 |
95Mo | 0.8 | 42.1 |
138La | 294.4 | 389.7 |
182W | 4.0 | 32.2 |
238U | —a | 10.6 |
The inorganic elements other than Fe and U are found in the size range less than 10 nm and their distributions are largely overlapped with those of the organic colloids detected by UV absorption and fluorescence emission. These trends are consistent with the results of the previous Fl-FFF study19 and suggest a possible role for organic colloids as hosts for these inorganic elements, although the presence of inorganic colloids constituting the elements with relatively large concentrations such as Al and Ca and incorporation of the trace elements is likely as well. Some elements such as Al, Ca, Sr, and La exhibit additional peaks in the washing step at tr ∼ 76 min, where no organic colloids exist, according to the UV and fluorescence fractograms. This suggests the presence of relatively large inorganic colloids. In the previous study both Sr and Ca showed similar fractograms with broad peaks around 20 nm,19 which are not seen in the present study. Although the peak locations are different, similar behaviors of these elements observed in this and the previous studies strongly suggest the presence of common underlying processes governing them.
One of the most important findings in the Fl-FFF analysis of the granitic groundwater, compared with the previous study,19 is the absence of colloids in an intermediate size range at dH > 18.7 nm and tr < 30 min. The latter corresponds to about 140 nm, if the range of the size calibration is extrapolated. Aosai et al.34 investigated the size distribution of rare earth elements (REEs) in granitic groundwater samples collected from a different borehole at the same depth in the Mizunami URL as that of the present study, using an in situ micro/ultrafiltration device and scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDX). They found that more than 50% of REEs were associated with colloids with size ranges of 10 kDa to 0.2 μm and 0.2–0.45 μm, consisting of Fe, Al, Mg, and Si. Although the discrete nature of the filtration technique makes direct comparison difficult and Si and Mg were not successfully measured in this study, these findings seem to agree with the results in Fig. 2.
All inorganic elements exhibit peaks in a similar size range as the organic colloids. This suggests an important role for organic colloids as host phases for the inorganic elements, as is the case for the granitic groundwater. Aluminum and Fe show additional peaks at >5 nm; Al has three peaks at tr = 6 (dH = 10 nm), and 20, and 30 min; Ca has a peak around tr = 30 min; Fe has a broad peak around tr = 20 min. As no peaks are observed in the UV/Vis and fluorescence fractograms in these tr, the results indicate that inorganic colloids including these elements exist at relatively large sizes. Some of the elements such as Cu (tr ∼ 20 min) and Sr (tr > 30 min) have small peaks in these regions. As the concentrations of these elements in the fractograms are smaller than those of Al, Ca, and Fe, they may bind to such inorganic colloids.
Kozai et al.22 measured the molar mass distribution of organic materials and various elements in sedimentary groundwater sampled at −500 m of a surface well at the Horonobe URL by SEC-ICP-MS. They found multiple peaks of organic materials and inorganic elements in the <150 kDa region of the chromatograms, which may correspond to the size of 3–4 nm. They concluded that U was associated with low molecular-weight Si species (∼1500 Da) containing Na, K, Ca, and Al. Although the comparison of their SEC results and the Fl-FFF results in this study is not straightforward, as the fractionation range and resolution are rather different, it is most likely that the peaks at <5 nm in Fig. 3 consist of various components.
Fig. 4 Comparison of the UV/Vis (UV) and fluorescence (FL) fractograms of the organic colloids up to 10 nm in the granitic (a) and sedimentary (b) groundwater. |
The fractograms of the selected inorganic elements are compared in the size range up to 10 nm in Fig. 5. Once normalized and overlaid, it is clear that the inorganic elements in the granitic groundwater exist in larger sizes than those in the sedimentary groundwater. In the granitic groundwater the fractograms of the different elements tend to overlap with each other; the peak positions are around 4 nm and different from that of the corresponding UV/Vis fractogram, but close to that of the fluorescence fractogram (Fig. 4). This may indicate stronger binding of these elements to organic colloids rich in fluorophores. Another possibility is the presence of inorganic colloids composed of, for instance, Al, whose concentration is relatively high in the Fl-FFF-ICP-MS analysis, and the uptake of trace elements such as Mn and La, as mentioned above. The fractograms of the inorganic elements in the sedimentary groundwater depend on the types of elements and can be categorized into two groups. The elements in the first group are Ca, Mn, and La; they have relatively narrow peaks with maxima from 1.5 to 2 nm, which correspond with those in the fractogram of the organic colloids. The second group may include Al, Fe, Cu, Sr, W, and U; they exhibit broader peaks with maxima around 2.5 nm. Similar to the granitic groundwater there might be inorganic colloids in this size range, which capture trace elements such as U.
Fig. 5 Comparison of the normalized fractograms of the organic colloids measured by UV/Vis absorption and selected inorganic elements up to 10 nm in the granitic (a) and sedimentary (b) groundwater. |
In summary the fractograms of the organic colloids and those of most of the inorganic elements strongly overlapped at <10 nm for both groundwater samples. At >10 nm some inorganic elements (Al, Ca, Fe, Cu, and Sr) exhibited peaks in their fractograms, suggesting the presence of larger inorganic colloids. Organic colloids in the granitic groundwater were determined to be heterogeneous with respect to their sizes and the compositions of chromophores and fluorophores, in contrast to those in the sedimentary groundwater. Most of the inorganic elements at <10 nm in the granitic groundwater showed peaks at similar sizes, corresponding to the peak location of the fluorescence fractogram of this groundwater. On the other hand, the distributions of the inorganic elements in this size range of the sedimentary groundwater were divided to two groups; one included Ca, Mn, and La, having similar fractograms to the colloids; the other included Al, Fe, Cu, Sr, W, and U and exhibited broader fractograms with maxima around 2.5 nm. Complementary use of SEC, which has higher resolution in a smaller size region, would further resolve them.22 Various off-line microscopic techniques such as transmission electron microscopy and atomic force microscopy have been combined with Fl-FFF to further reveal the identities of size-fractionated colloids;20,36–38 such a combination should also work for Fl-FFF analyses of deep groundwater colloids. Locational and temporal variations of the size distributions and compositions of groundwater colloids should be investigated and discussed in relation to their correlation with corresponding geochemical and geological parameters.
Footnote |
† Former professor of the Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo. |
This journal is © The Royal Society of Chemistry 2015 |