aDepartment of Chemistry, University of Bath, Claverton Down, BA2 7AY Bath, UK. E-mail: s.pascu@bath.ac.uk
bDepartment of Nanostructures and Surfaces, Instituto de Ciencia de Materiales de Madrid – CSIC, Sor Juana Inés de la Cruz 3, Madrid, 28049, Spain
cDepartment of Radiology & Radiological Science, Johns Hopkins, 601 N Caroline St, Baltimore, MD 21205, USA
dDepartment of Electroceramics, Instituto de Cerámica y Vidrio – CSIC, Kelsen 5, Madrid, 28049, Spain
eWales Research and Diagnostic PET Imaging Centre, School of Medicine, Cardiff University, Cardiff, UK
fDepartment of Surgery and Cancer, Faculty of Medicine, Commonwealth Building, Hammersmith Campus, Imperial College London, Du Cane Road, London, W12 0NN, UK
First published on 17th March 2020
The gallium-68 radiolabelling of new functional graphene oxide composites is reported herein along with kinetic stability investigations of the radio-nanohybrids under different environments and insights into their surface characteristics by SEM and XPS. The present work highlights the potential of graphene oxides as nanocarriers for small molecules such as bis(thiosemicarbazonato) complexes to act as multifunctional platforms for rapid and effective radioimaging agent incorporation.
Several recent studies show that graphene oxide (GO) nanocomposites can be conjugated with polyethylene glycol (PEG) or small chelating molecules (e.g. 1,4,7-triazacyclononane-1,4,7-trisacetic acid, deferoxamine, etc.) and, in turn, radiolabelled with various radioisotopes (e.g. iodine-131, gallium-66, gallium-68, copper-64).8,23–25 for their use in nuclear imaging.
Recently Cai et al. suggested that the chelator-free labelling of GO nanocomposites with copper-64 is possible, allowing for the facile synthesis of new radio-nanocomposites with high kinetic stability.26,27 These radiolabelling processes can be carried out under mild conditions and rely on the interaction between the transition metal and π electrons and oxygen functionalities present on GO surface. Although this approach offers an attractive alternative for the radiolabelling of GO, only a few examples have been reported using copper-64 or fluorine-18.26–28
Despite the progress achieved so far, there are still many synthetic limitations to be resolved in order to develop new materials that are not only biocompatible but also stable, allowing for the development of new versatile contrast agents. In this sense, the large surface area of sp2-bound carbon in graphene oxide nanocomposites added to the presence of oxygen functionalities become a crucial factor for the functionalisation of graphene covalently, or non-covalently via π–π interactions, hydrogen bonding or van der Waals forces.
In this work, we demonstrated the feasibility of graphene oxide as a potential chelator-free imaging contrast in [68Ga]Ga(III)-radiolabelling with excellent radiochemical yields. The prepared graphene oxide nanocomposites also incorporated functional bis(thiosemicarbazonato) metal complexes and tested the applicability of these derivatives in vitro paving the way towards the potential application in PET imaging of graphene oxide-based multimodality imaging nanoprobes.
The unsymmetrical bis(thiosemicarbazonato) zinc complex (2), synthesised as described in Fig. 1 and ESI,† was selected for the potential enhancement of the GO-based radio-nanocomposite properties as related/similar compounds have shown inherent hypoxia selectivity.29,30 In this case, a free amino group incorporated in the ligand framework at the exocyclic N(H) in 2 opens the way for future straightforward bioconjugations. The synthesis of gallium bis(thiosemicarbazonato) complex was additionally carried out: the non-radiolabelled and radiolabelled gallium(III) complexes (3 and [68Ga]-3) were prepared via an optimised, transmetallation protocol from the corresponding zinc complex precursor (2) allowing for a reduction in reaction times and increased reaction yields (Tables S3 and S4, ESI†). The radiochemical purity of the gallium-68 complex was demonstrated by HPLC and radio-HPLC: Fig. 2(A) shows a comparison of the relevant traces of Compound 3 and the corresponding species [68Ga]-3.
The aqueous gallium(III) and [68Ga]gallium(III) ions were subsequently incorporated into two different nanoparticulate systems: a simple GO framework and a GO-based hybrid incorporating a molecular bis(thiosemicarbazonato) zinc complex (2@GO), as described in Fig. 1(B). The gallium-tagged nanocomposites were successfully prepared by mixing a GO suspension in DMSO (2 mg mL−1) with GaCl3 in a 4:1 ethanol:sodium acetate buffer solution (pH = 4.5) at 95 °C for 45 minutes. Next the [68Ga]Ga(III) radiolabelling was achieved following the analogous procedure employed for the non-radioactive counterparts. This resulted in the isolation of the two radioactive hybrids, or nanocomposites, denoted [68Ga]Ga@GO and [68Ga]Ga-2@GO. The source of the [68Ga]GaCl3 (aq.) i.e. whether it was generator vs. cyclotron produced did not appear to play a crucial role in the formation of a nanohybrid: the labelling was successful with gallium-68 produced by a cyclotron via the 89Zn(p,n)68Ga reaction in aqueous solution, or eluted through a [68Ge]/[68Ga] generator, in both cases the impurities present after extractions appeared to play a negligible role in the immobilisation of radioactive species within the support. All the reactions were monitored using radioactive instant thin layer chromatography (radio-iTLC). The radio-iTLC, based on the percentage of activity detected on the baseline by paper chromatography (Whatman 3MM), suggested that after 45 min the radiochemical conversion (RCCs) for both [68Ga]-labelled GO nanocomposites was higher than 99% as single radioactive species were detected for each Radio-iTLC run (Fig. 2B and Fig. S65 of ESI†). The radiochemical yield of crude gallium-68 nanocomposites was calculated to be notably high and varied between the different nanocomposites used from 98 ± 4.6% to 99.7 ± 0.74%. It can be assumed that labelling was enabled by interactions of the oxophilic Ga(III) ion with the surface functionalities of GO, although transition metal-π electron interactions based on the electron transfer between Ga(III) cations, well-known hard/intermediate Lewis acids and π electron density on the surface of GO, may further facilitate this binding.
The kinetic stability of both non-radiolabelled (Ga@GO and Ga-2@GO) and radiolabelled nanocomposites ([68Ga]Ga@GO and [68Ga]Ga-2@GO) was evaluated under various conditions. For the kinetic stability tests of the non-radiolabelled complexes, (Ga@GO and Ga-2@GO) UV-visible absorption spectroscopy was employed. Specifically, 2 mg mL−1 concentration of the assay agent (complex Ga@GO or Ga-2@GO) dispersed in DMSO was used. Dispersions of assay agents in 1:1 DMSO:H2O mixtures were prepared, and the assays were carried out by incubating the samples at 37 °C using citric acid, PBS, EDTA and DFO. Both complexes were found to be sufficiently stable in the timescale of an imaging experiment with respect to decomposition in a mixture of DMSO and several aqueous buffers, which are of relevance to standard cellular imaging assays. Whilst there were no changes observed in the UV/Vis spectra after 30 minutes of incubation, some slight changes were observed after 24 hours of incubation (Fig. S52 in ESI†). Moreover, on account of the short half-life (t1/2) of [68Ga]Ga(III) (68 minutes), the kinetic stability of the radiolabelled compounds was tested after incubation at 37 °C for 60 and 120 minutes. It was found that the stability profile of the radiolabelled complex was high with >98% of the radiolabelled GO nanocomposites remaining intact during incubation in biological media (e.g. PBS, mouse plasma) at a volume ratio of 1:1 of the radiolabelled GO nanocomposites to biological media. On the other hand, the stability in EDTA decreased compared to biological media with only >65% remaining intact after one hour, which might be caused by the strong ability of EDTA to bind gallium(III).31Fig. 3 shows a bar graph representation summarising the stability assay results for the [68Ga]Ga@GO and [68Ga]Ga-2@GO nanocomposites. Interestingly, the ananlogous methodology could be extrapollated to the chelator-free [89Zr]Zr-labelling of GO [ESI†]. The incorporation of (cyclotron-produced) aqueous 89Zr(IV) into the 2@GO hybrid was also attempted to test the hypothesis that the Lewis acidity and oxophilicity of Zr(IV) would lead to specific radiolabelling. Further investigations of the potential radiolabelling using [89Zr]Zr(IV) (aqueous ions, frequently highlighted as a mixture of colloidal oxo-zirconium ions) in the presence of the well-known zirconium chelator, the siderophore-like deferoxamine (DFO) derivative, were carried out hereby. The radiolabelled [89Zr]ZrDFO was treated in turn with the GO and 2@GO nanocomposites and a 70% radio-incorporation of this complex was observed. We hypothesise that this could be caused by non-covalent binding between GO nanocomposites and DFO. Our experiments did not indicate a strong kinetic stability of the resulting 89Zr(IV)-tagged radio-nanohybrids and did not confirm the strong binding of the zirconium-89 to GO in the absence of the established chelator deferoxamine (DFO) (ESI, Fig. S40†).
Fig. 3 Kinetic stability tests: [68Ga]Ga@GO (left) and [68Ga]Ga-2@GO (right) Nanocomposites were exposed up to 2 h to challenges under various incubation conditions described in ESI.† Error bar stands for standard error (±SE), calculated from three independent, repeated, measurements. |
To aid our understanding into the interaction within the GO nanocomposites and gallium species on the nanoscale, further analysis through TEM, SEM and EDX in the ‘cold’ Ga(III) chemistry was applied. The electron microscopy images of the corresponding ‘cold’ compounds indicated some level of aggregation of the Ga+3 ions and of the Ga-2 complex on the surface or between the layers of the GO flakes, suggesting an interaction in solution (ESI†). The EDX mapping of Ga-2@GO showed a high binding affinity of Ga(III) on the GO surface, supporting the hypothesis that when bis(thiosemicarbazonato) Zn(II) complex is incorporated non-covalently within the GO layers, the normally straight-forward transmetallation Zn(II)/Ga(III) reaction30 seems less favourable (Fig. 5). In order to confirm the bonding condition of gallium and surface functionalizations of graphene oxide XPS measurements were performed. In survey scans, the expected emissions from core level peaks can be observed (C 1s, N 1s, Zn 2p, Cl 2p, O 1s and Ga 3p and 3d. These were present in samples Ga (3) and Ga-2@GO, and C 1s, Cl 1s, O 1s and Ga 3p and 3d for Ga@GO. For chemical analysis and comparison purposes, N 1s, Zn 2p and Ga 3d levels were selected (Fig. 6). Interestingly, Fig. 6(a) depicts the XPS emission attesting the presence of traces of Zn: from the Zn 2p core level, whose binding energy and core level splitting values confirm the presence of Zn2+ in both Ga (3) and Ga-2@GO samples. The existence of Zn in the sample Ga (3) can be ascribed to the transmetallation reaction, and therefore the presence of small amounts of the Zn thiosemicarbazonato precursor, which are undetectable through analytical techniques such as HPLC, NMR or mass spectrometry. Fig. 6(b) shows the XPS spectra corresponding to the N 1s core level: for the samples Ga (3) and Ga-2@GO a peak at ca. 399 eV can be observed corresponding to the emission from N of the thiosemicarbazonato complexes; correspondingly no N-related signal was detected for the Ga@GO sample due to the absence of the thiosemicarbazato complexes. In addition, for all samples a Cl 2p peak (Fig. S50, ESI†) corresponding to the Cl–Ga bond was readily seen. The sample Ga@GO shows, as expected, the highest Cl percentage, due to the use of GaCl3 as the Ga(III) source. The obtained data confirms the presence of Ga(III) ions in all samples (Fig. 6c). Both the binding energy position of the Ga 3d photoemission peak (ca. 21 eV) and the LMM Auger transitions (Fig. S50 ESI†), shifted 3.0 eV and 6.0 eV with respect to the values for metallic Ga, respectively, confirming the presence of Ga3+ (ESI†). A detailed analysis of the Ga 3d energy region provides more information of its chemical state. At first, subtle line shape asymmetry is observed on the low binding energy side, which might be indicative of an additional emission associated to a lower chemical state. Therefore, core level fit has been performed considering components from O 2s, Ga 3d, Cl 3s, S 3s and Zn 3d signals present in that energy region. The deconvolution results are displayed in Fig. 6(d), (e) and (f) for all the samples. In addition to the main contribution attributed to Ga3+, a minor component assignable to Ga–OH exists (denoted Ga+1 in the Fig. 6), suggesting the possible presence of Ga–OH-graphene oxide surface conjugations for Ga@GO and Ga-2@GO and of Ga(OH)3 for Ga (3).33–36 This is an unprecedented account into the behaviour of gallium ions in presence of graphene oxides and also shows an insight for the first time into the Zn(II)/Ga(III) transmetallation from XPS spectroscopy.
Furthermore, the cellular uptake of the complexes 2 and 3 and the corresponding nanocomposite 2@GO in living PC-3 cancer cells was investigated by laser confocal fluorescence microscopy (ESI†). Whilst these species display weak fluorescence emission, consistent with all related studies on metallated bis(thiosemicarbazonato) species, this was sufficient to perform in vitro imaging (Fig. 4 and ESI†) by confocal fluorescence microscopy. Complex 2 exhibited a stronger fluorescence emission when localised within the cytoplasm of living HeLa, PC-3 and MCF-7 cell lines, in line with previously reported observations.29 Interestingly, complex 3 shows a stronger fluorescence emission intensity under hypoxic conditions (ESI†) consistent with previous findings on the hypoxia selectivity of this family of gallium compounds supported on rigid N/S ligand frameworks.29,30 Cellular cytotoxicity investigations performed on the non-radiolabelled compounds in PC-3 and EMT-6 cancer cell lines (ESI†) confirmed the low toxicity of the synthesised graphene oxide nanocomposites in these particular cell lines, being suitable candidates as synthetic scaffolds for anchoring imaging agents. Crystal violet assays were carried out in the PC-3 and EMT-6 cancer cell lines. All the GO composites investigated had low to minimum toxicity under the selected experimental conditions11 and in the case of the molecular compounds, their IC50 values are in line with previous investigations into this family of bis(semithiocarbazonato) complexes29 (Fig. S24–S29, ESI†). Functional graphene oxides are now well known to be excreted in vivo through the kidney and the gut:32 lack of cellular toxicity reinforce the possibility of sustainable and safe radioactivity entrapment by metal compounds anchored onto the 2D layers of graphene oxides.
Footnotes |
† Electronic supplementary information (ESI) available: Detailed Experimental section, spectroscopic and materials characterisations, radiolabelling, cellular imaging and cytotoxicity assays. See DOI: 10.1039/c9nr10145d |
‡ These authors contributed equally to the work. |
This journal is © The Royal Society of Chemistry 2020 |