Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

Abstract

Shear horizontal surface acoustic wave (SH-SAW) sensors are widely used in biosensing for marker detection and can also measure particle size. This study leverages SH-SAW technology with a reflective-type design and unique packaging technology to distinguish lipoprotein sizes on a 3 × 5 mm sensor chip, addressing the limitations of traditional, time-consuming methods like chromatography and nuclear magnetic resonance (NMR). A 250 MHz SH-SAW biosensor on 36° rotated Y-cut 90° X-propagating quartz substrates was used, with ApoA1, ApoB48, ApoB100, and Lp(a) antibodies immobilized on a gold surface to capture lipoproteins from human plasma. The ratio of velocity to attenuation changes, defined as the layer-parameter, was analyzed, and numerical calculations validated the experimental results. ApoA1-, ApoB48- and ApoB100-containing lipoproteins, as well as Lp(a), exhibited different sizes, with corresponding layer-parameter values of −0.398 ± 0.009, −1.133 ± 0.043, −0.661 ± 0.024, and −0.497 ± 0.035, respectively. These values demonstrated a strong correlation (R = 0.9987) between lipoprotein size and the increase in layer thickness. This study highlights that analyzing layer-parameters enables the estimation of lipoprotein size, thereby expanding the clinical potential of SH-SAW biosensors for point-of-care testing (POCT).

Graphical abstract: Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

Supplementary files

Transparent peer review

To support increased transparency, we offer authors the option to publish the peer review history alongside their article.

View this article’s peer review history

Article information

Article type
Paper
Submitted
06 mag 2025
Accepted
17 giu 2025
First published
01 lug 2025

Lab Chip, 2025, Advance Article

Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

C. Cheng, H. Yatsuda and J. Kondoh, Lab Chip, 2025, Advance Article , DOI: 10.1039/D5LC00444F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements