D.
Caballero
abc,
J.
Katuri
ad,
J.
Samitier
abc and
S.
Sánchez
*ade
aInstitute for Bioengineering of Catalonia (IBEC), Baldiri Reixac 15-21, 08028 Barcelona, Spain. E-mail: ssanchez@ibecbarcelona.eu
bCentro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain
cDepartment of Engineering: Electronics, University of Barcelona, 08028 Barcelona, Spain
dMax Planck Institute for Intelligent Systems, Heisenbergstrasse 3, Stuttgart, Germany. E-mail: ssanchez@is.mpg.de
eCatalan Institute for Research and Advanced Studies (ICREA), Psg. Lluís Companys, 23, 08010 Barcelona, Spain
First published on 19th October 2016
The ubiquitous random motion of mesoscopic active particles, such as cells, can be “rectified” or directed by embedding the particles in systems containing local and periodic asymmetric cues. Incorporated on lab-on-a-chip devices, these microratchet-like structures can be used to self-propel fluids, transport particles, and direct cell motion in the absence of external power sources. In this Focus article we discuss recent advances in the use of ratchet-like geometries in microfluidics which could open new avenues in biomedicine for applications in diagnosis, cancer biology, and bioengineering.
The development of microfluidic devices which incorporate ratchet-like structures within microchannels to direct the transport of fluids, particles, and cells has received significant attention as a new way to direct motion in the absence of an external power source. These new techniques provide multiple advantages compared to standard techniques, which require the use of external sources, such as bulky pumps, pressure gradients, or oscillatory electrical fields. This will allow the development of novel autonomous microfluidic devices with promising applications in biomedicine. In this Focus article, we summarize some recent works combining microfluidics with ratchet-based propulsion systems to direct fluids along microchannels, transport passive and active particles, and sort and guide cells within microfluidic devices.
Fig. 1 Application of ratchet-like microstructures for fluid transport. (a) Scheme showing the fabrication of polymeric isotropic and anisotropic structures for the unidirectional transport of fluids. (b) Different ratchet configurations within a microchannel induce different fluid behaviors with different fluid flow speeds. (c) A drop of water self-propels when deposited on a hot surface containing asymmetric features. (d) (Left) Scanning electron microscopy image of tilted micro- and nano-pillars. (Right) Average horizontal velocity vs. tilted pillars height showing the two size-dependent mechanisms governing the motion of dynamic Leidenfrost droplets. Reprinted from ref. 5 (c) and ref. 6 (d) with permission. Panels (a) and (b) adapted from ref. 4. |
Liquid droplets were also shown to self-propel if placed on ratchet-like structures. For this to occur, liquids must be in the so-called Leidenfrost state, when a drop levitates if placed on a hot surface whose temperature is far above their boiling point. The generated vapor flow sustains and propels the drop with reduced friction with the underlying substrate towards the direction set by the ratchet. However, the elevated temperatures needed to reach the Leidenfrost state limit the lifetime of the drop motion, which, in the best scenario, is a few hundreds of seconds. Remarkably, coating the surface with a hydrophobic layer reduces the temperature needed to self-propel liquid drops. In this regard, Dupeux et al. used hot (100 °C) ratchet-like milli-sized structures functionalized with a superhydrophobic coating to self-propel deionized water droplets unidirectionally (Fig. 1c).5 The motion of the levitating droplets was rectified by the asymmetric teeth and directed against the feature tilt. The propulsion was a consequence of the rectification of the vapour flow by the asymmetric ratchet structures. Liquid speed was observed to hardly depend on the ratchet temperatures, but interestingly, droplet motion was observed below 100 °C which implied that levitation was not necessary to induce motion.
Liquid directionality on Leidenfrost ratchets depends on features size and orientation. Nanometric features, such as tilted pillars, have been shown to direct droplet directionality towards the same tilting direction, whereas on micro- and millimetre scale droplets move against the feature tilt angle. In order to identify the mechanism at work explaining this switch in directionality, Agapov et al. developed a dynamic Leidenfrost ratchet consisting of tilted micro- and nano-pillars, and studied the directionality of impacting deionized water droplets on a level hot (350 °C) plate (Fig. 1d, left).6 The authors revealed an interplay between asymmetric vapour flow phenomena and asymmetric wettability which determined droplet directionality. The former dominated in the case of large feature sizes (micro and milli-scale), whereas the latter governed droplet motion at the nanometric scale (Fig. 1d, right). Intriguingly, no preferential directed motion was observed when the droplets were gently deposited on the tilted pillars surface, but moved randomly. Under this gentle deposition condition, the vapor film was too thick to allow droplet–surface interaction at the top of the nanopillars and rectify droplet motion. In this case, liquid speed was observed to linearly depend on ratchet features size. Transition between both regimes (wettability vs. vapour flow) occurred when the features size reached the microscale.
In summary, these works show that directed fluid flow can be achieved by using ratchet-like structures integrated in microfluidic systems. These findings could have important applications in lab-on-a-chip devices, including the transport and targeted delivery of reagents, on-chip immunoassays or guiding chemical reactions, where the control of the direction and timing of fluid flow is critical.
Fig. 2 Particle transport using ratchet structures. (a) A conductive particle between two electrodes suspended in a dielectric fluid. Every time the particle makes contact with an electrode, it acquires a charge and migrates towards the opposite electrode. (b) Schematic of the ratcheted microfluidic channel used to direct particle transport. (c) Trajectory of a particle undergoing directed motion. (d) Particle trajectory in a microfluidic channel designed to separate conductive particles from fluid flow. (e) The mean squared displacements (MSD) of colloidal particles in the absence of bacteria (simple Brownian motion, open symbols) and in a bacterial bath (filled symbols). (f) A scanning electron microscopy image of a square structure that gathers particles to the centre. (g) (Upper panels) Snapshots of particles and bacteria in the initial and final state. The latter state shows the system when the particles are strongly affected by bacterial transport over asymmetric barriers. (Lower panels) Particle distributions averaged over a steady state between t1 = 15 min and t2 = 20 min (left). The right panel shows the particle distribution in an experiment without bacteria. Reprinted from ref. 7 (a–d) and ref. 8 (e–g) with permission. |
Another system that could spatially organize colloidal particles in an active suspension of bacteria was developed by Koumakis et al.8 Active particles, such as bacteria and self-propelled colloids, are animated by non-equilibrium stochastic forces characterized by a persistence time on the timescale of seconds. Passive colloidal particles suspended in a bath of swimming bacteria have also been shown to display random walks with a finite persistence time (Fig. 2e).9 When the persistence time is large enough to probe topological features in rigid obstacles, the particles can be rectified using effective asymmetric energy barriers. These asymmetric barriers were created by patterning a flat surface with a 3D structure containing three square boundaries with the larger slopes pointing either inwards (to collect particles) or outwards (to eject particles) (Fig. 2f and g). In the absence of bacteria, the particles sediment close to the bottom surface and are randomly distributed. The asymmetric walls present an energy barrier of 20 kBT which confines the sedimented particles. However in the presence of an active suspension of swimming bacteria, which introduces off-equilibrium fluctuating forces, the distribution of colloids is no longer homogeneous. After 20 min, the collecting structures are filled up and the ejecting structures are empty of colloids (Fig. 2g). A number of parameters, such as the height and slope of the structures or the particle size can influence the rectification process. One particular parameter that was tested was the density of the bacterial suspension. When the bacterial concentration is high, the particles acquire higher diffusivity and are less sensitive to the underlying topographical landscape making the rectification process less effective.
The two methods described above, while not exhaustive, serve as good examples of how well designed ratchet structures can be used to achieve directional transport of colloidal particles in the absence of external pressure gradients.
Fig. 3 Cell sorting and guidance using ratchets. (a) Ratchet-sorting device with alternating upwards and downwards flows, and cross flow, which permits the sorting of cells depending on their mechanical deformation. (b) (Upper panel) Optical image displaying the flow of RBCs. (Lower panels) Cells are sorted depending on their membrane rigidity (left) and deposited on the appropriate outlet (right). (c) Cells seeded on a topographical ratchet bias their dynamics and direction of motion. (d) The direction of cell motion depends on the ratchet geometry and size. (e) Microbial biosensor device containing ratchet-like microchannels to direct bacteria growth. (f) Concentration-dependent experiments can be performed in bacteria-containing chambers. Reprinted from ref. 10 (a and b), ref. 14 (c and d), and ref. 15 (e and f) with permission. |
Ratchet-like structures can also be used to ‘rectify’ (from random to directional) the motion of motile cells in the absence of chemical or mechanical gradients.1–3,12,13 Recently, the bias of cell motility by means of ratchets was termed Ratchetaxis.1In vivo, this type of motion can synergize with chemical gradients leading to complex cell behaviors. This was addressed in vitro by Comelles et al. using a combination of a topographical ratchet coated with a fibronectin gradient.2 Depending on their respective orientations, both cues cooperated or competed in guiding cell motion. The authors identified the mechanical interaction of the cell nucleus with ratchet structures as the mechanism polarizing the cell which determined the final direction of cell motion. Note that the geometry and size of the ratchet structures can influence both the direction of motion and the organelle responsible of the bias.1,2 In this regard, Sun et al. used asymmetric sawteeth structures to bias the internal actin polymerization waves, imposing cell polarization and directing cell motility.14 The direction of cell motion depended on sawtooth length and height, suggesting the presence of multiple competing mechanisms involved in biasing actin waves (Fig. 3c). Importantly, for a specific ratchet configuration, the direction of bias was conserved for different cell types suggesting a universal intracellular mechanism responsible for breaking the symmetry (Fig. 3d). This is in contrast with former works where the direction of motion critically depended on the cell type and the selected ratchet geometry.3 This cell-dependent phenomenon provided the possibility to sort different cell types or to fabricate “cancer traps” that can be incorporated in lab-on-a-chip devices or even in vivo.3
The use of ratchet-based structures can also be extended to bacteria. In this regard, Kim et al. developed a microfluidic platform for the detection of heavy metal ions (HMIs) using microbial biosensors.15 Ratchet-shaped microchannels were embedded within the platform to self-concentrate and retain the bacteria in a microchamber array (Fig. 3e). Due to the specific geometry of the ratchet structures, swimming bacteria were forced to grow and accumulate within each individual chamber. Nutrient supply and waste disposal was ensured by constant media flow and diffusion. The developed device incorporated multiple filling channels which permitted the analysis of varying HMIs concentrations, while keeping the concentration of microbes constant in all the test chambers (Fig. 3f). In this case, microbes acted as sensing entities which were genetically modified for GFP expression. This approach improved the sensitivity for detecting Pb2+ and Cd2+ ions by approximately three orders of magnitude when compared to standard methods.15
Altogether, these works reveal that cell motion can be biased over large distances by means of ratchets. This provides multiple advantages compared to chemical gradients which degrade over time and the migrating distance is limited by the detection capability of cells, typically a few cell bodies.