Open Access Article
Vincent
Pautu†
a,
Laurine
Marger†
b,
Maja
Caf
cd,
Fabrice
Marger
ab,
Mustapha
Mekki
b,
Slavko
Kralj
*cd and
Irena
Milošević
*a
aSchool of Engineering, Architecture and Landscape of Geneva (HEPIA), HES-SO – University of Applied Sciences and Arts Western Switzerland, Switzerland. E-mail: irena.milosevic@hesge.ch
bLaboratory of Biomaterials, Faculty of Medicine, University Clinics of Dental Medicine, University of Geneva, Genève, Switzerland
cDepartment for Materials Synthesis, Jožef Stefan Institute, Jamova 39, Ljubljana, Slovenia. E-mail: slavko.kralj@ijs.si
dFaculty of Pharmacy, University of Ljubljana, Aškerčeva 7, Ljubljana, Slovenia
First published on 27th March 2026
Biofilms are structured communities of bacteria embedded within an extracellular polymeric substance (EPS) matrix, which forms a protective barrier that restricts drug penetration and increases antibiotic tolerance, making their complete elimination particularly challenging. Here, we investigate a magneto-mechanical approach using rotating magnetic fields (RMFs) to deliver controlled mechanical stress to Enterococcus faecalis biofilms via anisotropic magnetic particles (AMPs). Microrods, nanochains, and nanorods with distinct sizes and magnetic properties were actuated under identical RMF conditions on implant-relevant titanium substrates. Micron-scale magnetic microrods generate sufficient magnetic torque to mechanically disrupt the EPS matrix and detach biofilm structures, significantly increasing suspended bacterial cells without marked bactericidal effects. In contrast, nanoscale AMPs do not induce biofilm detachment but cause membrane damage, increasing the proportion of injured cells. These findings demonstrate a size-dependent transition between microscale biofilm detachment and nanoscale membrane interactions, identifying particle size as the dominant parameter governing magneto-mechanical biofilm disruption.
Once established, biofilms create a barrier that protects bacteria from conventional antimicrobial therapies by restricting drug penetration, increasing antibiotic tolerance, and facilitating intercellular communication, which increases resistance and diminishes the efficacy of treatment against biofilms.4 This resistance results in persistent infections and complicates both preventive and therapeutic strategies, as resistance to antibiotics is augmented by approximately 1000-fold.5 The biofilm matrix is not only a biochemical barrier but also a mechanical barrier with spatially varying stiffness and relaxation times. This barrier gives biofilms their characteristic resilience and tolerance to shear, which can be even more pronounced when grown under shear conditions.6–8 As an example, scaling and root planing are employed to eliminate plaque and biofilm; however, these mechanical procedures, involving scraping and smoothing teeth roots, are often inadequate for the complete eradication and enduring elimination of all microorganisms.9 Among them, Enterococcus faecalis (E. faecalis) is frequently detected in persistent endodontic and peri–implant infections and is well known for its ability to survive conventional mechanical debridement and irrigation procedures. Its capacity to form highly resilient biofilms, combined with tolerance to disinfectants and antibiotics, makes E. faecalis a likely contributor to residual biofilm and reinfection around dental and implant surfaces.10
The adhesion strengths underline why physical removal or preventive surface modification is critical. Such strong bacterial adhesion is a primary reason why titanium implants are vulnerable to peri-implant infections, necessitating advanced anti-biofilm surface technologies or nanoparticle-based approaches for long-term protection and easy cleaning.11
From a materials perspective, the problem caused by biofilms is primarily mechanical rather than biological: how can one apply a controlled stress strong enough to fragment or detach such a structure without relying solely on chemical agents? This mechanical challenge is compounded by the fact that the EPS matrix acts as a dense viscoelastic protective barrier, severely limiting the penetration of antimicrobial agents into the encapsulated bacterial cells.
Addressing this dual challenge, both physical disruption and enhanced penetration, has led to the development of various strategies to disrupt the biofilm structure and improve the delivery of antibacterial agents. Among these approaches, the use of magnetic nanoparticles has emerged as a promising tool due to their ability to disrupt the biofilm matrix and enhance antibiotic delivery. Iron oxide nanoparticles (IONPs) under a static magnetic field used in conjunction with antibiotics demonstrate significant efficacy in eradicating bacteria within the biofilm.12,13 These studies used the magnetic responsiveness of spherical nanoparticles to facilitate the formation of channels and penetration inside the biofilm matrix and consequently enhance the accessibility of antimicrobial agents to the bacterial cells.
However, the central challenge remains: how to inject sufficient mechanical energy into the hydrated EPS network to achieve disruption? Magnetic actuation offers a contactless route to deliver mechanical work and provides one possible solution to deliver controlled energy through rotating magnetic fields (RMFs), which generate a magnetic torque (τ = μ × B, where τ is the magnetic torque, μ is the magnetic moment and B is the magnetic field) on magnetic objects. This torque converts magnetic energy into rotational motion at the micro- or nanoscale and depends on the magnetic moment of the materials and the magnetic field applied. Unlike static magnetic approaches, RMF-driven rotation offers the potential to mechanically disrupt the biofilm structure through continuous physical agitation.
Building upon this principle, more advanced systems rely on magnetic particles with anisotropic shapes, which are able to rotate under exposure to RMFs.14,15 The mechanical work delivered by these systems correlates with both magnetic anisotropy and the aspect ratio of the particles. This approach relies on the conversion of magnetic energy into mechanical agitation and creates not only unidirectional channels but also generates rotational mechanical movement that results in biofilm sensitization, enhanced infiltration, and physical disruption due to the magnetic torque generated by the rotating anisotropic magnetic particles (AMPs). In essence, AMPs combine the penetration-enhancing benefits of spherical magnetic nanoparticles with the added mechanical disruption capability of sustained rotational motion, offering a multifaceted strategy for biofilm eradication.16,17
In this work, various AMP objects, named nanorods, nanochains, and microrods, were prepared based on (1) the magnetic assembly of IONPs obtained through a modified Massart's coprecipitation method18 or (2) the chemical reduction of an akageneite precursor.19 The influence of such AMPs differing in their aspect ratios, size and magnetic characteristics and subjected to a RMF was studied on an E. faecalis biofilm. The bacterial detachment from the biofilm was analysed using flow cytometry, allowing us to compare the biofilm-disrupting efficiency of the different AMP types.
The MMRs were then produced by magnetic assembly of citric acid-coated nanoparticles (MNP-CA), followed by silica deposition for structural fixation.23 First, an aqueous suspension of MNP-CA nanocrystals (75 mL) and, separately, a 0.172 M tetraethyl orthosilicate (TEOS) solution in absolute ethanol were prepared. The nanoparticle suspension was stirred at 400 rpm for 2 minutes, followed by the addition of 1.5 mL of 25% aqueous ammonia to initiate the sol–gel process. The TEOS solution was then added dropwise under continuous stirring. After approximately 1 minute, 3.0 mL of a saturated NaCl aqueous solution was introduced to enhance rod formation through ionic strength modulation. The mixture was stirred for an additional 2 minutes and subsequently exposed to an external magnetic field (24 mT) and left undisturbed overnight to facilitate magnetic alignment and silica condensation. The resulting microrods were collected and purified by magnetic separation and repeated washing with deionized water to remove unreacted components and excess MNP-CA.
To improve the structural stability of the anisotropic microrods, an additional thin silica shell was deposited. The previously synthesized magnetic microrods were dispersed in a solvent mixture of 100 mL of deionized water and 250 mL of absolute ethanol. In parallel, 17 mL of a 0.790 M TEOS solution in ethanol was prepared. To initiate the silica coating process, 1.65 mL of 25% aqueous ammonia (NH4OH) was added to the microrod suspension, followed by the gradual addition of the TEOS solution under continuous stirring at 250 rpm. To ensure sustained hydrolysis and condensation, additional two aliquots of NH4OH (1.65 mL each) were added at one-hour intervals during the reaction. The coating process was allowed to proceed for a total of four hours. Upon completion, the silica-coated microrods were collected and purified by repeated magnetic separation and washing with deionized water to remove any unreacted precursors and by-products.
For MNR synthesis, the hydrophobic nanoparticles were dispersed in dichloromethane to a final volume of 5 mL (5 mg mL−1). In parallel, a solution of 20 mL of deionized water and 80 mL of absolute ethanol was prepared in a beaker positioned within a 37 mT magnetic field. A mechanical stirrer was introduced and set to operate at 500 rpm. To initiate the synthesis, 2.5 mL of 25% aqueous ammonia (NH4OH) was added to the ethanol–water mixture. The hydrophobic iron oxide nanocrystal suspension was then introduced dropwise into the vigorously stirred solution. After 5 minutes of continuous stirring, the external magnetic field was removed and 200 µL of tetraethyl orthosilicate (TEOS) was added dropwise. The reaction mixture was stirred for an additional 30 seconds and subsequently left undisturbed for 3 hours to allow for silica condensation. The resulting MNRs were collected by magnetic separation and purified through three washing cycles with absolute ethanol, followed by three washes with deionized water.
The silica coating of β-FeOOH nanorods was performed following a modified Stöber process, adapted from a previously published protocol.31 Briefly, 100 mg of β-FeOOH nanorods were dispersed in a mixture consisting of 140 mL of absolute ethanol, water (15 mL final concentration), and 10 mL of ammonium hydroxide solution (25 wt%). The suspension was stirred for 5 min at room temperature to ensure homogeneous dispersion. Subsequently, 5 μL of tetraethyl orthosilicate (TEOS), pre-diluted in 10 mL of ethanol, was added dropwise to the mixture under vigorous stirring. The reaction was allowed to proceed for 2 h at room temperature to form a uniform silica shell around the nanorods. The resulting SiO2@β-FeOOH nanorods were collected by centrifugation at 7600g for 5 min, washed three times with ethanol, and redispersed in 10 mL of ethanol to obtain a final concentration of 10 mg mL−1.
A total of 100 mg of SiO2@β-FeOOH nanorods was recovered by centrifugation at 7600g for 10 min to remove the ethanol supernatant. The pellet was redispersed in 20 mL of oleylamine and transferred into a microwave reaction vessel. Argon gas was bubbled through the mixture for 5 min to eliminate dissolved oxygen and air from the vessel. The vessel was then sealed and heated to 200 °C for 2 h under microwave irradiation.
After cooling to room temperature, the resulting black product was recovered by magnetic separation, washed six times with a mixture of ethanol and isopropanol, followed by three washes with ultrapure water. The final product was redispersed in 5 mL of ultrapure water.
Before characterization, each plate was subjected to a standardized cleaning sequence: (1) ultrasonic cleaning in a 3% (v/v) titanium-specific alkaline detergent (Galvex® 17.3%, NGL Cleaning Technology, Switzerland) in deionized water for 10 min; (2) double rinse in deionized water (2 × 2 min); (3) rinse in isopropanol (≥99.5%) for 2 min; and (4) drying with filtered compressed air (Class 100). After cleaning, the plates were sterilized by saturated-steam autoclaving at 121 °C for 20 min and stored in heat-sealed sterile pouches until use.
Sterile grade 4 titanium plates (dimensions: 10 mm × 10 mm) were placed in 24-well plates, and each well was inoculated with the standardized E. faecalis suspension. The plates were incubated for 24 hours at 37 °C to allow biofilm formation.
These AMPs were suspended at defined concentrations in PBS and added to each well.
Magnetic agitation was performed using a rotating magnetic field generated by a 2mag MIXdrive 24 MTP system (Germany) operated at 33 Hz or 2000 rpm at the maximum power (10 W). Instead of the magnetic hyperthermia regime, which relies on high-frequency (>100 kHz) alternating magnetic fields to generate heat,17 the present work uses the low frequency regime under a rotating magnetic field to deliver “controlled mechanical stress,” which is far from any heating contribution originating from magnetic nanoparticles. The protocol consisted of three agitation cycles of 3 min each (total agitation time 9 min).
Between each agitation cycle, the suspension of AMPs was briefly resuspended manually with a 200 µL pipette to maintain a homogeneous particle distribution, minimize aggregation, and preserve the effective rod aspect ratio and torque generation.
The necessity and efficiency of this resuspension step were verified in a preliminary optimization experiment using MMRs at 100 ppm (iron concentration). Three conditions were compared under identical RMF parameters:
(i) a control without rods (mechanical resuspension only), (ii) MMRs with manual resuspension between each 3-minute cycle (3 × 3 min + resuspension), and (iii) MMRs without resuspension (continuous 9-minute agitation).
At the end of the agitation, both the planktonic fraction and the bacteria adhered to the titanium surfaces were collected. The discs were vortexed and sonicated as previously described.
The staining solution was prepared by mixing SYTO9 and PI in a 1
:
1 ratio in PBS. Equal volumes of the staining solution and bacterial suspension were mixed and incubated for 15 minutes at room temperature in the dark. Samples were analyzed using a CytoFLEX flow cytometer (Beckman Coulter MoFlo Astrios) equipped with four lasers, counting 10
000 objects.
Excitation/emission settings were SYTO9 (Ex. 488 nm/Em. 504–555 nm) and PI (Ex. 561 nm/Em. 570–675 nm). Samples were acquired at a flow rate of 10 µL min−1 for 120 s and analyses were restricted to the bacterial gate (approximately 106 cells per mL). Cytometric gates were established using bacterial reference controls including untreated live cells, ethanol-killed cells (70% EtOH, 10 min), and single-stained controls (SYTO9 only or PI only) to verify channel separation. Based on these controls, three populations were defined live (SYTO9+/PI−), membrane-compromised (“injured”) (SYTO9+/PI+), and dead (SYTO9−/PI+). Results were expressed as the percentages of live, injured, and dead bacterial cells. To quantify bacteria detached by the different AMPs and present in suspension, the number of events per µL was measured for each group and normalized to the control group. All experiments were performed in triplicate.
Samples were sputter-coated with a 20 nm layer of gold and examined using a Sigma 300 VP FE-SEM (Zeiss, Germany) to visualize the biofilm morphology.
| Materials | Length (nm) | Width (nm) | Aspect ratio | Emu g−1 |
|---|---|---|---|---|
| MMR | 12 600 ± 5200 |
605 ± 184 | 22.8 ± 11.6 | 33.9 |
| MNC | 882 ± 255 | 193 ± 26 | 4.6 ± 1.5 | 13.1 |
| MNR | 1900 ± 700 | 94 ± 13 | 19.9 ± 7.8 | 15.4 |
| FMNR | 61 ± 21 | 10 ± 2 | 6.5 ± 2.2 | 3.0 |
MMRs were assembled from citric acid-stabilized iron oxide nanocrystals through magnetic field-directed aggregation, resulting in rod-like structures with an average length of 12.6 ± 5.2 µm and a width of 605 ± 184 nm. These superparamagnetic assemblies exhibited a saturation magnetization of 33.9 emu g−1 (Fig. 2A). MNCs were prepared by magnetic assembly of 100 nm-sized nanocrystal clusters into chain-like structures with dimensions of 882 ± 255 nm (length) × 193 ± 26 nm (width) and a saturation magnetization of 13.1 emu g−1 (Fig. 2B). MNRs exhibited dimensions of 1900 ± 700 nm × 94 ± 13 nm with a saturation magnetization of 15.4 emu g−1 (Fig. 2C). FMNRs, synthesized through a three-step process involving akageneite precursors and organo-thermal reduction, measured 61 ± 21 nm × 6.5 ± 2.2 nm and displayed weak ferromagnetic behavior with a remanent magnetization of 0.9 emu g−1 and a saturation magnetization of 3.0 emu g−1. All AMPs were stabilized with a silica shell to preserve the morphology during agitation and provide a biocompatible, hydroxyl-rich surface for biofilm interaction, a critical consideration given that particle aggregation or surface chemistry changes could confound mechanical effects with unintended biological interactions.32 All the characteristics of the different AMPs are summarized in Table 1 for more clarity.
![]() | ||
| Fig. 2 Room-temperature measurements of the mass magnetization as a function of magnetic field for the MMRs (A), MNCs (B), MNRs (C), and FMNRs (D). | ||
The use of commercially pure titanium grade 4 substrates with a cold rolled finish provided an implant relevant baseline representative of clinically used titanium surfaces.11,33,34 This choice was made to reproduce realistic dental and implant conditions while maintaining a controlled and reproducible substrate.
Surface characterization was performed prior to biofilm experiments. Profilometry confirmed a homogeneous surface topography with a roughness Ra of 0.82 ± 0.03 µm (see SI Table S1). Static water contact angle measurements indicated moderate hydrophilicity with a value of 79.8 ± 0.8° (see SI Table S2), consistent with the presence of a native titanium dioxide passive layer on titanium surfaces.11,33
This characterization documents that all experiments were conducted on comparable substrates. It minimizes substrate-driven variability between samples and supports the interpretation of the magneto mechanical effects as particle dependent rather than surface dependent. Prior to conducting the magneto-mechanical experiments on biofilms, the magnetic field generated by the 2mag MIXdrive was characterized to ensure consistent RMF exposure across all wells (see SI Tables S3 and S4 for magnetic field values at different powers and frequencies). Under the operating conditions used for biofilm experiments (100% power, 33 Hz), the average field strength at the titanium disc level was 8.6 ± 1.5 mT (range 7.13–10.87 mT). This field strength is consistent with previous work on effective magneto-mechanical biofilm disruption, where the magnetic nanochains actuated at <20 mT and <10 Hz achieved 99.99% bacterial kill when combined with methicillin.16
Using MMRs at 100 ppm, three conditions were compared: (i) control without rods (mechanical resuspension only), (ii) MMRs with manual resuspension between each 3-minute cycle, and (iii) MMRs without resuspension (continuous 9-minute agitation). Bacterial detachment from titanium discs was quantified by flow cytometry based on the number of detached bacterial events per µL in the collected suspension. The control conditions produced an average of 707 ± 111 events per µL, whereas agitation with MMRs and intermediate resuspension resulted in 2307 ± 177 events per µL, significantly higher than both the control and the non-resuspension conditions (1550 ± 1111 events per µL, p < 0.05, t-test). These results confirm that manual resuspension between agitation cycles substantially improves the mechanical efficiency of magnetic actuation by preventing particle aggregation and maintaining homogeneous rotational behavior of the MMRs in suspension. Consequently, the 3 × 3 min RMF protocol with intermediate resuspension was adopted for all subsequent experiments involving other types of smaller AMPs.
To provide a clinical reference, E. faecalis biofilms grown for 24 h on titanium discs were exposed to 0.1% chlorhexidine (CHX) for either 30 s (typical dental clinical exposure) or 9 min, matching the RMF treatment duration. SEM imaging revealed a reduction in biofilm coverage after 30 s and a more pronounced decrease after 9 min. However, residual bacterial structures remained visible on the titanium surface, indicating that CHX treatment under these conditions did not fully eliminate the biofilm (see the SI, Fig. S1). Notably, even extended CHX exposure (9 min) did not fully eliminate the biofilm from the titanium surface, suggesting that chemical disinfection alone may leave residual biofilm structures. Mechanical biofilm disruption strategies may therefore represent a complementary approach for implant surface decontamination. Bacterial viability analysis was also performed after AMP treatment to determine whether bacterial detachment resulted from mechanical action or due to membrane damage and hence biocidal effects. The analysis of the suspended bacteria following MMR treatment revealed that detachment was primarily mechanical and the effect was not biocidal. While the proportion of injured cells (SYTO9+/PI+, indicating partial membrane compromise) showed a non-significant upward trend (+11.3 ± 14.4%), live and dead populations remained relatively unchanged compared to controls (Fig. 3B). Although nanoscale AMPs failed to detach the biofilm, viability analysis of bacteria remaining on titanium surfaces revealed a distinct mechanism: bacterial membrane damage without physical removal (Fig. 4). The proportion of injured cells increased significantly from 2.6 ± 0.8% in controls to 4.9 ± 1.2% (MNCs), 6.1 ± 1.2% (MNRs), and 4.6 ± 1.2% (FMNRs) (p < 0.005 to p < 0.001; Fig. 4B) and no significant increase was observed for MMRs. Live cell populations remained statistically unchanged (∼83.5%), while dead cells showed non-significant upward trends. Importantly, a copper surface was included as a positive control to assess strong bactericidal activity, which produced marked decreases in live bacteria (33.6% vs. 89.5% in the control) and a concomitant increase in injured (20.2% vs. 2.6%) and dead cells (45.2% vs. 4.4%). This positive control confirmed the sensitivity of the experimental setup to detect strong bactericidal effects.
The nanoscale AMPs induced a slight increase in dead cells and a significant rise in injured cells on the titanium surface compared to the control and MMRs. These injured cells are indicative of stress or sub-lethal damage that can impair bacterial function or enhance susceptibility to adjunctive treatments. These results are consistent with the literature, suggesting that certain nanomaterials can disrupt bacterial membranes without killing the cells, acting through surface interactions or mechanical nano-effects.36 Although this study primarily assessed membrane integrity, additional assays could further clarify the physiological stress responses induced by nanoscale AMPs. In particular, evaluating metabolic activity (e.g., NADPH/NADH balance) or stress-related structures such as protein aggregates or stress granules would provide valuable insights into the sublethal effects of magneto-mechanical interactions on bacterial cells.
Numerous studies show that nano-sized magnetic particles (<100 nm) interact more strongly with bacterial membranes than micro-sized particles.37,38 Their higher surface-to-volume ratio enhances their ability to attach to and penetrate the bacterial cell envelope, leading to greater membrane disruption, increased permeability, and ultimately cell lysis. In contrast, micro-sized magnetic particles exhibit reduced membrane interaction and lower antibacterial activity, as their larger size limits close contact and penetration into bacterial membranes. Thus, the observed differences between MMRs and other AMPs can be attributed to their respective nanoscale dimensions (e.g., widths of 605, 193, 94, and 10 nm for MMRs, MNCs, MNR, and FMNR, respectively). An additional important factor is the particle number density. All AMP types were applied at identical iron concentrations; therefore, nanoscale AMPs were orders of magnitude more numerous than MMRs. The substantially higher collision/impact frequency between nanoscale particles and bacterial cells likely increases membrane perturbation and explains the higher fraction of membrane-compromised bacteria observed. However, because the magnetic torque scales strongly with particle volume, the torques generated by individual nanoscale particles remain insufficient to overcome biofilm adhesion forces and induce large-scale detachment. Surprisingly, FMNRs with the smallest dimensions compared to other AMPs did not show an increased percentage of injured cells. This phenomenon can be attributed to their ferromagnetic properties creating persistent dipole–dipole attractions that drive the aggregation of FMNRs even without field exposure.39 In contrast, superparamagnetic nanoparticles only become magnetized in the presence of an external field and lack remanent magnetization, resulting in much weaker interparticle attractions and less spontaneous aggregation. As a result, the aggregation of FMNRs, especially under a magnetic field, reduces their effective interaction with bacterial membranes, thereby limiting their ability to cause bacterial membrane damage and cell injury.
Importantly, the short-time agitation protocol used in this study, three cycles of 3 minutes, was designed to reflect realistic clinical application in dentistry. In the context of dental biomaterials, particularly in endodontics or implant decontamination, any adjunctive treatment must be both rapid and minimally invasive to be feasible in a dental office setting. Moreover, in our previous study, MNCs showed no toxicity to Caco-2 intestinal epithelial cells, regardless of whether magneto-mechanical force was employed or not.40 The chosen protocol ensures that the AMP suspension maintains its physical and colloidal stability during agitation, which is critical since the aggregation of AMPs could reduce mechanical efficacy or alter undesired biological interactions. Maintaining dispersed AMPs is especially important for membrane-level interactions, which were likely responsible for the observed increase in injured cells. Therefore, the current protocol not only demonstrates biological efficacy but also supports potential translational use in chairside treatments, where time efficiency and safety are essential. This may reflect a limitation in treatment duration or intensity, or a need to combine mechanical agitation with chemical or photodynamic agents for enhanced bacteria toxicity, as proposed in earlier work with dentin bonding agents or rose bengal photosensitization.36,41
Supplementary information: characterization of titanium plates and further experimental procedures are available in Tables S1 and S2, magnetic field characterization in Tables S3 and S4, SEM images before and after CHX treatment in Fig. S1, and in situ visualization of synchronous rotation in the SI video. See DOI: https://doi.org/10.1039/d6nr00046k.
Footnote |
| † These authors contributed equally. |
| This journal is © The Royal Society of Chemistry 2026 |