Issue 3, 2023

Assessment of long tubing in measuring atmospheric trace gases: applications on tall towers

Abstract

Perfluoroalkoxy alkane (PFA) Teflon tubing has been widely used to draw air samples for analyzing atmospheric trace gases. However, impacts of long tubing on measurements of atmospheric trace gases have rarely been reported so far, especially for various organic trace gases. In this study, interactions between long tubing and various trace gases were assessed using a combination of laboratory tests, field experiments, and modeling techniques. A tower-based observation system of trace gases was also established using long tubes. The results show that measured concentrations of organic compounds required varying amounts of time (e.g., 10–474 s for a 400 m-long tubing at a flow rate of 13 standard liters per minute) to stabilize after traversing the tubing. Tubing delays of organic compounds were highly dependent on their saturation concentrations and the residence time in the tubing. In laboratory tests, there are no detectable losses of the targeted chemical species after traversing the 400 m-long tubing. In real applications, concentrations of nitric oxide (NO) cannot be well measured through long tubes in the daytime due to its low ambient concentrations and rapid consumption by ozone. Negligible losses were observed for most of the other targeted species when measured using long tubes. Measurements of various trace gases made by the vertical observation system can well characterize their concentrations and vertical distributions. However, the measurements of a trace gas made by the vertical observation system at each altitude cannot be used to interpret its temporal variability at time scales lower than its tubing delay. In addition to their usage on tall towers, long PFA Teflon tubes can be also used on mobile platforms (e.g., tethered balloons) for vertical measurements of atmospheric trace gases or to surveil emissions of targeted chemical species at multiple sites.

Graphical abstract: Assessment of long tubing in measuring atmospheric trace gases: applications on tall towers

Supplementary files

Transparent peer review

To support increased transparency, we offer authors the option to publish the peer review history alongside their article.

View this article’s peer review history

Article information

Article type
Paper
Submitted
18 अगस्त 2022
Accepted
19 फरवरी 2023
First published
23 फरवरी 2023
This article is Open Access
Creative Commons BY-NC license

Environ. Sci.: Atmos., 2023,3, 506-520

Assessment of long tubing in measuring atmospheric trace gases: applications on tall towers

X. Li, C. Zhang, A. Liu, B. Yuan, H. Yang, C. Liu, S. Wang, Y. Huangfu, J. Qi, Z. Liu, X. He, X. Song, Y. Chen, Y. Peng, X. Zhang, E. Zheng, L. Yang, Q. Yang, G. Qin, J. Zhou and M. Shao, Environ. Sci.: Atmos., 2023, 3, 506 DOI: 10.1039/D2EA00110A

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.