Issue 3, 2020

High-precision cerium isotope analysis by thermal ionization mass spectrometry using the Ce+ technique

Abstract

The 138La–138Ce isotope system has been regarded as a useful radiogenic tracer for geochronology studies. Compared to the commonly-used CeO+ technique, the measurement of Ce isotope ratios as Ce+ is more straightforward and more advantageous, but it is challenging due to the severe isobaric interference of 138Ba on 138Ce and large variations in relative abundances of all Ce isotopes. In this study, a novel method has been developed for high-precision measurement of Ce isotope ratios by thermal ionization mass spectrometry (TIMS) as Ce+. A newly-developed film porous ion emitter (FPIE) was used to enhance the ionization of Ce as Ce+ ions. The employment of TaF5 as an activator significantly suppressed the Ba+ isobaric interference signal. 140Ce was proposed to be an alternative reference Ce isotope as there is no isobaric interference on 140Ce and complicated peak tailing correction can be avoided. The combinations of diverse amplifiers (1010 Ω, 1011 Ω, 1012 Ω and 1013 Ω) were used for the measurement of Ce isotope ratios as Ce+ and 137Ba was monitored simultaneously on a 1013 Ω amplifier for 138Ba interference correction. The reproducibility of Ce isotope ratios obtained was ca. 10-fold better than the previously published Ce+ results and even comparable with that obtained using the more laborious CeO+ techniques. This method was further applied for the analysis of reference rock samples and uranium ores of world-wide origin. The analytical results demonstrated that Ce isotope ratios could be a promising signature for the nuclear forensic investigation to identify the source of unknown nuclear materials.

Graphical abstract: High-precision cerium isotope analysis by thermal ionization mass spectrometry using the Ce+ technique

Supplementary files

Article information

Article type
Paper
Submitted
09 दिसम्बर 2019
Accepted
17 जनवरी 2020
First published
27 जनवरी 2020

J. Anal. At. Spectrom., 2020,35, 467-477

High-precision cerium isotope analysis by thermal ionization mass spectrometry using the Ce+ technique

X. Shao, W. Bu, Y. Fan, K. Long, H. Yang, L. Tang, C. Cheng, X. Liu and F. Hao, J. Anal. At. Spectrom., 2020, 35, 467 DOI: 10.1039/C9JA00420C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements